Lang Manufacturing PFL-120 Installation Manual

Installation, Operation, Maintenance and Service Instructions
Model: PFL 120
Lang Manufacturing 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W742 Ph: 314-678-6314 Fax: 314-781-2714
Rev A
www.langworld.com May 21, 2007
TABLE OF CONTENTS
Table Of Contents.....................................................................................................2
Installation.................................................................................................................3
RECEIVING THE APPLIANCE..........................................................................................3
DATA PLATE INFORMATION...........................................................................................3
ELECTRICAL CONNECTION............................................................................................4
Operation..................................................................................................................5
CONTROLS..................................................................................................................5
STARTUP....................................................................................................................5
PROOFING GENERAL ...................................................................................................5
PROOFING SPECIFICS..................................................................................................6
HOLDING CABINET.......................................................................................................6
Maintenance .............................................................................................................7
CLEANING...................................................................................................................7
Parts List...................................................................................................................8
Wiring Diagram.......................................................................................................10
Installation
RECEIVING THE APPLIANCE
Upon receipt of the appliance, check for freight damage both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered, make a written request for inspection by the carrier's agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Lang Manufacturing Company. File your claim with the carrier. Uncrate the appliance as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
DATA PLATE INFORMATION
A data plate is located on the right side, lower front corner. The voltages, wattage, serial number, wire size and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.
3
Electrical Connection
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 3­PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE PLUG.
120 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1). The electrical service entrance is provided by a cord and plug. Each appliance requires a 120 volt grounded supply and 16.7 amps. Supply wire size must be 14 gauge or larger to carry the load for one proofer. The plug type is NEMA S-20P; match the plug to the corresponding NEMA S-20R for the receptacle (receptacle not supplied).
240 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1). The electrical service entrance is provided by a cord and plug. Each appliance requires a 240/208 volt grounded supply and 16.7 amps. Supply wire size must be 14 gauge or larger to carry the load for one proofer. The plug type is NEMA #6-15P, match the plug to the corresponding NEMA #6-15R for the receptacle (receptacle not supplied).
VOLTAGE AMPERAGE WATTAGE
120 13.0 1550 240 6.5 1550
4