Installation,
Operation, Maintenance and
Service Instructions
Hinged Proofer
Model: PFL 120
Lang Manufacturing 10 Sunnen Drive St. Louis, MO.63143-3800
Part Number: 2M-W742 Ph: 314-678-6314 Fax: 314-781-2714
Rev A
www.langworld.com May 21, 2007
TABLE OF CONTENTS
Table Of Contents.....................................................................................................2
Installation.................................................................................................................3
RECEIVING THE APPLIANCE..........................................................................................3
DATA PLATE INFORMATION...........................................................................................3
ELECTRICAL CONNECTION............................................................................................4
Operation..................................................................................................................5
CONTROLS..................................................................................................................5
STARTUP....................................................................................................................5
PROOFING GENERAL ...................................................................................................5
PROOFING SPECIFICS..................................................................................................6
HOLDING CABINET.......................................................................................................6
Maintenance .............................................................................................................7
CLEANING...................................................................................................................7
Parts List...................................................................................................................8
Wiring Diagram.......................................................................................................10
Installation
RECEIVING THE APPLIANCE
Upon receipt of the appliance, check for freight damage both visible and concealed. Visible damage
should be noted on the freight bill at the time of delivery and signed by the carrier's agent.
Concealed loss or damage means loss or damage, which does not become apparent until the
merchandise has been unpacked. If concealed loss or damage is discovered, make a written
request for inspection by the carrier's agent within 15 days of delivery. All packing material should
be kept for inspection. Do not return damaged merchandise to Lang Manufacturing Company. File
your claim with the carrier.
Uncrate the appliance as near its intended location as practical. The crating will help protect the unit
from the physical damage normally associated with moving it through hallways and doorways.
DATA PLATE INFORMATION
A data plate is located on the right side, lower front corner.
The voltages, wattage, serial number, wire size and clearance specifications are on the data plate.
This information should be carefully read and understood before proceeding with the installation.
3
Electrical Connection
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING)
PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND
MUST BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 3PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE
PLUG.
120 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local
codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 120 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA S-20P; match the plug to the corresponding NEMA S-20R for the receptacle
(receptacle not supplied).
240 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local
codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 240/208 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA #6-15P, match the plug to the corresponding NEMA #6-15R for the
receptacle (receptacle not supplied).
VOLTAGE AMPERAGE WATTAGE
120 13.0 1550
240 6.5 1550
4