THE INFORMATION IN THIS MANUAL IS CRUCIAL AND MUST BE RETAINED FOR
FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
DANGER
WARNING
CAUTION
NOTICE
POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH.
POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH OR SERIOUS INJURY.
POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY.
Helpful operation and installation instructions and tips are
present.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY
OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.
MOVING PARTS HAZARD. FOLLOW LOCKOUT PROCEDURES BEFORE
REMOVING AIR DUCT OR EVAPORATOR FAN GUARDS
ELECTRICAL HAZARD BEHIND UPPER FRONT TRIM. FOLLOW LOCKOUT
PROCEDURES BEFORE SERVICING.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
NOTICE
NOTICE
NOTICE
CAUTION
NOTICE
WARNING
CAUTION
The Retard mode will operate without using the timer if continuous
retarding is desired.
Service on this or any other LANG equipment must be performed by
qualified personnel only. Consult your authorized service agency
directory or call the factory at 1-800-224-LANG (5264), or
WWW.LANGWORLD.COM for the service agency nearest you
A qualified & licensed refrigeration mechanic must perform connection,
evaluation & charging of refrigeration lines. The condenser unit, if
supplied, is recharged, but additional refrigerant may be required.
THE ADHESIVE WILL NOT RELEASE FOR A SECOND TRY.
For units needing more than one piece of trim to span one side, join the
two pieces by overlapping with the ceiling trim cap.
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE MOUNTED ON
FLOORS OF NON-COMBUSTIBLE CONSTRUCTION WITH NONCOMBUSTIBLE FLOORING AND SURFACE FINISH AND WITH NO
COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE THEREOF, OR ON
NON-COMBUSTIBLE SLABS OR ARCHES HAVING NO COMBUSTIBLE
MATERIAL AGAINST THE UNDERSIDE THEREOF. SUCH CONSTRUCTION
SHALL IN ALL CASES EXTEND NOT LESS THAN 12 INCHES BEYOND THE
EQUIPMENT ON ALL SIDES.
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE,
ANSI/NFPA 70-1996.
CAUTION
WARNING
FOR INSTALLATION IN CANADA THE INSTALLATION MUST BE IN
ACCORDANCE WITH CAN/CGA-B149.1&2 OF THE INSTALLATION CODE,
AND LOCAL CODES WHERE APPLICABLE. ALL ELECTRIC WIRING MUST
BE IN ACCORDANCE WITH THE CURRENT CANADIAN ELECTRICAL
CODE, C22.1 PART 1. GROUNDING THIS APPLIANCE MUST CONFORM
TO CANADIAN ELECTRICAL CODE, CSA C22.2.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY AND PLUMBING IMPROPER
INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND /OR DAMAGE
TO EQUIMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICAL CODES
ETL File E8138 Rev. A 2001
4
SAFETY PROCEEDURES
WARNING
WARNING
MOVING PARTS HAZARD. FOLLOW LOCKOUT PROCEDURES BEFORE
REMOVING AIR DUCT OR EVAPORATOR FAN GUARDS
ELECTRICAL HAZARD BEHIND UPPER FRONT TRIM. FOLLOW LOCKOUT
PROCEDURES BEFORE SERVICING.
Lockout Procedure
1. Announce lockout to other personnel.
2. Turn both heat and control power off at main panel.
3. Clear unit of all personnel.
4. Test lockout by turning power switch on and observing if control panel displays or fan(s) come on.
Check heater circuit with voltmeter.
5. Perform necessary repairs or tests.
6. Clear unit of personnel before restarting.
7. Turn power on at main panel.
8. Announce unit is “on” to other personnel.
Safety Precautions
The Manufacturer, Lang Manufacturing, hereby disclaims any and all responsibility for injury, damage,
loss or other claim that may occur to person or property from improper alteration, modification, addition,
operation, maintenance or service, whether it be mechanical, electrical, fuel, operator motor or otherwise,
which may occur from such improper alteration, modification, addition, operation, maintenance or service
to this piece of equipment.
Safety Considerations
Your Lang LRR Retarder is manufactured to rigid standards. This equipment is E.T.L. listed and meets
safety and sanitation standards.
The presence of safety equipment control and interlocks on an appliance and attendant components of
installation cannot in and of themselves, assure absolute safety of operation. Diligent, capable, well
trained operators and maintenance personnel, as well as proper programs of operation and maintenance,
are essential to the safe and reliable operation of this appliance.
A. The responsibility of the manufacturer
recommendations for the operation and maintenance of the appliance.
B. Trained qualified and factory-authorized personnel must perform all operation, maintenance and
repair of these appliances. It is the responsibility of the owner / operator
happens.
C. A regular periodic program of cleaning, inspection and maintenance must be established and
comprehensive maintenance records maintained. It is the sole responsibility of the user
schedule and enforce the frequency and scope of these programs in keeping with recommended
practice and with due consideration given to actual operating conditions.
D. The appliance must be operated within the limits, which will not exceed the working limits of
any component within the appliance as a whole.
is to supply suitable, comprehensive instructions and
to ensure that this
to establish,
ETL File E8138 Rev. A 2001
5
EQUIPMENT DESCRIPTION
Exterior
LRR2
• The Retarder exterior dimensions are 78.8” (200 cm) wide x 91.5” (232.5 cm) high x depth is dependent
upon model number [39.3”(100 cm) to 129.3” (328.5cm)]. The Top, Front, Back, and Sides are
constructed of stainless steel.
All Units
• Modular design allows for a wide variety of sizes.
• The retarder door is constructed of stainless steel and comes with both single and double doors.
Interior
LRR2
• The Retarder interior dimensions are 68.1” (173 cm) wide x 74.1” (188.25 cm) high x depth is dependent
upon model number [27.1”(68.8 cm) to 117.1” (297.4 cm)]. The Top, Front, Back, and Sides are
constructed of stainless steel.
All Units
• Floor level loading.
Cabinet
Rigid, formed stainless steel panels filled with polyurethane foam insulation re-joined with camlocks and
sealed with gaskets to form a strong, energy efficient, tight and sanitary enclosure.
Doors
The welded stainless steel doors are polyurethane foam-filled. Door bumpers on the inside protect the
finish.
Controls
• The microprocessor based digital controls are mounted for ease in the right-hand door. Power and light
switches are located above the left hand door.
• Digital read-out with solid-state temperature sensing and controls.
Evaporator(s)
Each Retarder retarder comes with one or two evaporators. These evaporators perform the task of cooling
the interior of the unit, while maintaining a relatively high level of humidity. The evaporators,
manufactured by Russell, consist of refrigeration coils, a thermal expansion valve, and a fan.
Condensing Unit
The condensing unit may or may not be provided with the system. Customers may choose to run off of a
remote refrigeration system. If used, the condensing unit consists of a compressor, a fan, a receiver, a line
drier and a solenoid valve. If the condensing unit is not used, the solenoid valve will still be provided to
control unit cooling.
ETL File E8138 Rev. A 2001
6
GENERAL DESCRIPTION
Theory of Operation
The Lang Retarder is a controlled atmosphere chamber. Temperature can be set independently to meet
your retarding needs. Air is circulated continuously to provide positive movement from bottom to top,
creating a uniform distribution cool air.
Retarder Theory
ETL File E8138 Rev. A 2001
7
GENERAL OPERATION
DANGER
Controls
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
RETARDER OPERATION
1. Turn Retarder on.
2. Press “Temp.” button.
3. Set temperature to desired temperature (34°F-45°F) using the “Up” or “Down” buttons.
4. Press the “Timer” button.
5. Set time to desired time using the “Up” or “Down” buttons.
6. Place product in the Retarder.
7. Press “Start / Stop” button and timer will begin counting down.
8. When buzzer sounds, press stop button and remove product from Retarder.
9. To check actual temperature press “Temp.” button twice. Flashing display will indicate actual temp.
NOTICE
ETL File E8138 Rev. A 2001
The Retard mode will operate without using the timer if continuous
retarding is desired.
8
GENERAL MAINTENANCE
NOTICE
Every Day
Clean interior and exterior of retarder.
Every Six Months
Have factory authorized service personnel check Retarder for proper temperature readings, and evaporator drain.
As Needed
Clean interior and exterior walls and replace light bulb or any other components as needed.
Specifications
Temperature, humidity, and timer setting ranges:
Retard:
Service on this or any other LANG equipment must be performed by
qualified personnel only. Consult your authorized service agency directory
or call the factory at 1-800-224-LANG (5264), or WWW.LANGWORLD.COM
for the service agency nearest you
34°-45°F (1°-8°C)
Timers:
Power:
0-99 Hours and 0-59 Minutes
Varies depending on model and size (See data plate located on the underside of the valence
for the specific ratings or contact the factory for the information needed if the data plate is
not legible).
Pre-Installation
Check the area where the Retarder is to be installed for the following:
No electrical junction boxes will be under the floor of the Retarder
Ceiling height above the Retarder should be sufficient to allow for installation. The minimum height
needed for installation is 95 inches.
Access is needed for an air-gap drain in any of the four corners.
Adequate space is needed in front of the Retarder to load and unload racks.
Local and national codes will require an electrical shut-off within a reasonable distance to the Retarder.
ASSEMBLY