Lang Manufacturing LRPR1 User Manual

LANG MANUFACTURING COMPANY • 6500 Merrill Creek Parkway, Everett, WA 98203
TOLL FREE: 800.882.6368 • FAX: 425.349.2733 • www.langworld.com
Item No.
Project
Quantity
BakerSeries
®
Roll-In Rack, Single Door Proofer-Retarder Model: LRPR1-Series
• Heavy duty stainless steel exterior with 300 Series stainless steel interior and aluminized steel top
•Walls, ceiling and door are foam insulated
• Modular wall and ceiling panels, designed for cam-lock on-site assembly
• Gasket seals provided at all seams and panel joints
• Quick response air-wash humidity/heat system with epoxy coated coils
• High capacity refrigeration system
• Designed for dual voltage 208 or 240-Volt, single or three phase power input
• Heavy duty door with removable magnetic door seal and mechanical closure system
PERFORMANCE FEATURES
Dual purpose unit provides both dough proofing and retarding
capabilities
70-120˚F proofing temperature range
34 - 45˚F retarding temperature range
Very accurate relative humidity control, with 50-95% operating
range
Same heating elements generate both heat and humidity. [No
submerged elements]
Large evaporator sized for high humidity levels, to prevent drying
High capacity refrigeration system for fast temperature pull-down
All power supply components mounted above door, with unit front
access
Interior bumpers protect proofer walls from rack damage
Full width grab bar handle protects door from rack dents
CONTROL PACKAGE
All controls located within the door, at eye level
Digital set TEMPERATURE, set HUMIDITY & TIME remaining
displays
Real time-of-day and automatic proof-start-time setting
Set temperature touch pads [1˚F increments]
Set relative humidity touch pads [1% increments]
SHORT/BID SPECIFICATION
Proofer/Retarder shall be a LANG Manufacturing Model LRPR1- ___ [Insert: 40, 50, 60, 70, 80, 90, 100, 110 or 120 depth] 5 to
6.6-kW electric heated, single door roll-in rack unit, with: quick response air-wash humidity/heat system; high-capacity refrigeration system; modular panel construction with cam-lock assembly; all 300 Series stainless steel interior, with protective cart bumpers; heavy duty door with magnetic seal/mechanical closure system and full width protective bar handle; simple computerized controls, door mounted at eye level, with accurate digital humidity, time and temperature readouts; plus all the features listed and options checked:
STANDARD PRODUCT WARRANTY
One year, parts & labor
Model LRPR1-40 shown
(Rack not included)
Sheet No. LSP-RR8 (rev. 10/03)
Model/ Side-Load End-Load Double Side Load Depth 28.4”W x 18”D 26”W x 20.4”D 36”W x 28.3”D
LRPR1-40 1 Rack 1 Rack None LRPR1-50 2 Racks 2 Racks 1 Racks LRPR1-60 2 Racks 2 Racks 1 Racks LRPR1-70 3 Racks 3 Racks 1 Racks LRPR1-80 4 Racks 3 Racks 2 Racks LRPR1-90 4 Racks 4 Racks 2 Racks LRPR1-100 5 Racks 4 Racks 2 Racks LRPR1-110 5 Racks 5 Racks 2 Racks LRPR1-120 6 Racks 5 Racks 3 Racks
MODEL/RACK CAPACITY GUIDE
®
USC
LANG MANUFACTURING COMPANY • 6500 Merrill Creek Parkway, Everett, WA 98203
TOLL FREE: 800.882.6368 • FAX: 425.349.2733 • www.langworld.com
© 2003 Lang Manufacturing Company Printed in U.S.A. 10/03-M-12266
Due to continuous improvements, specifications subject to change without notice.
OPTIONS & ACCESSORIES
Pass-through model [Consult Factory]Remote refrigeration condenser unit [Consult Factory]
Stainless steel floor
INSTALLATION REQUIREMENTS
• Proofer/Retarder shipped as modular panels for on-site assembly
•E Either 208V or 240V, 1 or 3-phase connection
• Condenser Unit requires dedicated circuit
•W 1/2” NPT cold water connection
•D 1/2” PVC vented drain connection [Connections from rear and top. See below]
Sheet No. LSP-RR8 (rev. 10/03)
[Front View/Elevation] [Right Side View] [Top View/Plan]
BakerSeries
®
Roll-In Rack, Single Door Proofer-Retarder Model: LRPR1-Series
CAD SYMBOLS & PRICING
Model
E Electrical Requirements Clearance from combustible W Water D Drain
Voltage Total kW 1 Phase 3 Phase
(inches from side, back)* Requirements Requirements
LRPR1 (40 - 120)
208VAC/60Hz 5.0 24.0A 13.8A
0
1/2” NPT 1/2” PVC
240VAC/60Hz 6.6 27.5A 15.8A
(1.5GPM @ 40PSI) (210˚F, 1GPM max.)
* Noncombustible floor only.
Retarder
Height Width Depth Weight
Freight
Model
BTU Rate @ 34˚F
Internal External Internal External Internal External Overall Actual Shipping
“A” “B” “C”
Class
LRPR1-40 1229
32.3” 41.1” 49.4” 950 lbs. 1100 lbs.
820mm 1044mm 1255mm 432 kg 500 kg
LRPR1-50
1696
42.4” 51.1” 59.4” 1100 lbs. 1250 lbs.
1077mm 1298mm 1509mm 500 kg 568 kg
LRPR1-60
1850
52.4” 61.1” 69.4” 1225 lbs. 1375 lbs.
1331mm 1552mm 1763mm 557 kg 625 kg
LRPR1-70
2308
64.4” 71.2” 79.5” 1375 lbs. 1525 lbs.
74.1” 91.4” 33.0” 38.7” 1636mm 1808mm 2019mm 625 kg 693 kg 70
LRPR1-80
2763
1882mm 2324mm 838mm 983mm
72.4” 81.2” 89.5” 1500 lbs. 1650 lbs.
1839mm 2062mm 2273mm 682 kg 750 kg
LRPR1-90
2907
82.5” 91.2” 99.5” 1625 lbs. 1775 lbs.
2096mm 2316mm 2527mm 739 kg 807 kg
LRPR1-100
3357
92.5” 101.2” 109.5” 1800 lbs. 1950 lbs.
2350mm 2570mm 2781mm 818 kg 886 kg
LRPR1-110
3497
102.5” 111.3” 119.6” 1925 lbs. 2075 lbs.
2604mm 2827mm 3038mm 875 kg 943 kg
LRPR1-120
3948
112.5” 121.3” 129.6” 2050 lbs. 2200 lbs.
2858mm 3081mm 3292mm 982 kg 1000 kg
38.7"/983mm
74.1"
1882mm
ENTRANCE
HEIGHT
91.4"
2324mm
14.8"/376mm W WATER
CONNECTION
9.1"/231mm
E ELECTRICAL
CONNECTION
(C)
2.9"/74mm
E & W
When Ordering With Ceiling
Mounted Condensing Unit,
Add 11.8"(300mm)
11.8"/300mm
87.3"
2217mm
3.7"/94mm
D DRAIN CONNECTION
(Alternate location)
13.1"/333mm
29.1"/739mm
E ELECTRICAL
CONNECTION
13.3"/338mm W WATER
CONNECTION
16.2"
441mm
28.9"
734mm
3.7"/94mm
D DRAIN CONNECTION
(Alternate location)
When Ordering With Ceiling
Mounted Condensing Unit.
Mounting Location
And Orientation Will Vary.
29.6"
752mm
33.0"/838mm
ENTRANCE WIDTH
(A)
(B)
4.0"/101mm
D DRAIN CONNECTION
Loading...