TIMER ELECTRIC 1-HR 24V SERVICE KIT
Instructions for Service Kit Q9-30800-05-1
Star Manufacturing International 10 Sunnen Drive St. Louis, MO 63143 P/N: 2M-W748 Phone: 1-800-807-9054, Fax 314-781-2714 Rev. - March 2007
Page 2
Table Of Contents
CHAPTER PAGE
TABLE OF CONTENTS.............................................................................. 2
KIT PARTS LIST......................................................................................... 3
TIMER WIRING DETAIL............................................................................. 4
MODEL ECCO INSTALL DETAILS............................................................ 5
MODEL EH INSTALL DETAILS ................................................................. 6
MODEL GCCO INSTALL DETAILS ........................................................... 7
Rev. A 2005
2
Page 3
Kit Parts List
Q9-30800-05-1
TIMER ELECTRIC 1-HR 24V SERVICE KIT
OTY DESCRIPTION PART NO.
1 TIMER ELECTRIC 1-HOUR 24VAC Q9-30800-05-11 1 ECCO RETRO TIMER BRACKET Q9-50309-080 1 EH RETRO TIMER BRACKET Q9-50309-081 1 GCCO RETRO TIMER BRACKET Q9-50309-082 2 SCRW ST PLT 8-32 X .5 PHD 2C-20102-04 3 SPACER SUPPORT 1/2LG NYLON 2K-70801-07
Rev. A 2005
3
Page 4
Timer Wiring Detail
BLACK / WHITE WIRE TO BUZZER BOARD (FROM WIRE HARNESS)
JUMPER
9Q-30800-05-11
YELLOW / WHITE WIRE, TO TERM STRIP (FROM WIRE HARNESS)
BLACK WIRE, WIRE NUT TO GROUND
Rev. A 2005
4
Page 5
ECCO Install Details
ECCO ACCU PLUS
1. REMOVE OLD TIMER.
2. ATTACH SUPPLIED 70801-07 SPACERS TO 50309-080 BRACKET AS SHOWN.
3. REMOVE CIRCUIT BOARD, LEAVING EXISTING 70801-07 SPACERS ATTACHED TO UNIT.
4. ATTACH CIRCUIT BOARD TO BRACKET­SPACERS AS SHOWN.
5. INSTALL NEW 30800-05-11 TIMER.
6. ATTACH BRACKET AND BOARD TO ORIGINAL SPACERS IN UNIT.
ECCO ACCU TEMP
1. REMOVE OLD TIMER.
2. INSTALL NEW 30800-05-11 TIMER.
MODEL: ECCO ACCU PLUS (SHOWN)
MODEL: ECCO ACCU TEMP (NOT SHOWN) SEE INSTALL NOTES
KIT INSTALLATION COMPLETE
MODEL: ECCO ACCU PLUS (SHOWN)
MODEL: ECCO ACCU TEMP (NOT SHOWN) SEE ABOVE INSTALL NOTES
Rev. A 2005
5
Page 6
Install Details
MODEL: EH ACCU PLUS
1. REMOVE OLD TIMER.
2. ATTACH SUPPLIED 70801-07 SPACERS TO 50309-081 BRACKET AS SHOWN.
3. REMOVE CIRCUIT BOARD AND ORIGINAL SPACERS (DISCARD ORIGINAL SPACERS).
4. ATTACH CIRCUIT BOARD TO BRACKET­SPACERS AS SHOWN.
5. REMOVE CONTACTOR FROM UNIT AND ATTACH TO BRACKET AS SHOWN.
6. INSTALL NEW 30800-05-11 TIMER.
7. ATTACH BRACKET ASSY TO UNIT WITH 20102-04, USING THE ORIGINAL CONTACTOR MOUNTING LOCATION.
KIT INSTALLATION COMPLETE
MODEL: EH ACCU PLUS
Rev. A 2005
6
Page 7
MODEL: GCCO ACCU PLUS (SHOWN)
MODEL: GCCO ACCU TEMP (NOT SHOWN) SEE INSTALL NOTES
GCCO Install Details
GCCO ACCU PLUS
1 REMOVE OLD TIMER. 2 ATTACH SUPPLIED 70801-07 SPACERS TO
50309-082 BRACKET AS SHOWN.
3 REMOVE CIRCUIT BOARD AND ORIGINAL
SPACERS (DISCARD ORIGINAL SPACERS).
4 ATTACH CIRCUIT BOARD TO BRACKET-
SPACERS AS SHOWN.
5 REMOVE CONTACTOR FROM UNIT AND
ATTACH TO BRACKET AS SHOWN.
6 REMOVE BUZZER BOARD & BUZZER
BOARD BRACKET FROM UNIT AND ATTACH
TO BRACKET AS SHOWN. 7 INSTALL NEW 30800-05-11 TIMER. 8 ATTACH BRACKET ASSY TO UNIT WITH
20102-04, USING THE ORIGINAL
CONTACTOR MOUNTING LOCATION.
GCCO ACCU TEMP
1. FOLLOW STEPS 1, 5, 6, 7, 8.
KIT INSTALLATION COMPLETE
MODEL: GCCO ACCU PLUS (SHOWN)
MODEL: GCCO ACCU TEMP (NOT SHOWN) SEE INSTALL NOTES
Rev. A 2005
7