11. PARTS LIST.........................................................................................25
PAGE
1
IMPORTANT READ FIRST IMPORTANT
CAUTION:EACH UNIT IS EXTREMLY HEAVY. FOR SAFE
HANDLING, INSTALLER SHOULD OBTAIN HELP AS
NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT,
DOLLY, OR PALLET JACK) TO REMOVE THE UNIT
FROM THE SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
CAUTION:ANY STAND, COUNTER OR OTHER DEVICE ON
WHICH GIDDLE WILL BE LOCATED MUST BE
DESIGNED TO SUPPORT THE WEIGHT OF THE
GRIDDLE.
CAUTION:SHIPPING STRAPS ARE UNDER TENSION AND CAN
SNAP BACK WHEN CUT.
DANGER:THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION
AND DEATH.
WARNING:INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY AND PLUMBING. IMPROPER
INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
UNIT MUST BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE CODES.
WARNING:BEFORE LIGHTING, USE A SOAP AND WATER
SOUTION TO TEST ALL JOINTS FOR GAS LEAKS.
WARNING:DURING INITIAL USE, OR AFTER SERVICE, IF PILOT
DOES NOT IGNITE ON FIRST TRY THE MAIN GAS
VALVE MUST BE TURNED OFF FOR AT LEAST FIVE
MINUTES.
NOTICE: The data plate is located left end of griddle behind
control door. The griddle voltage, gas specs, serial
number, pipe size, and clearance specifications are
on the data plate. This information should be
carefully read and understood before proceeding
with the installation.
NOTICE:The installation of any components such as a vent
hood, grease extractors, fire extinguisher systems,
must conform to their applicable National, State and
locally recognized installation standards.
NOTICE:During the first few hours of operation you may
notice a small amount of smoke coming off the
griddle plate, and a faint odor from the smoke. This
is normal for a new griddle and will disappear after
the first few hours of use.
2
IMPORTANT READ FIRST IMPORTANT
WARNING:KEEP WATER AND SOLUTIONS OUT OF CONTROLS.
NEVER SPRAY OR HOSE CONTROL CONSOLE,
ELECTRICAL CONNECTIONS, ETC.
CAUTION:ALWAYS KEEP THE AREA NEAR THE APPLIANCE
FREE FROM COMBUSTIBLE MATERIALS.
CAUTION:KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND
DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO
AVOID THE DANGER OF SLIPS OR FALLS.
CAUTION:MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES,
MUCOUS MEMBRANES AND CLOTHING.
PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER
GLOVES, GOGGLES OR FACE SHIELD AND
PROTECTIVE CLOTHING. CAREFULLY READ THE
WARNING AND FOLLOW THE DIRECTIONS ON THE
LABEL OF THE CLEANER TO BE USED.
NOTICE:Service on this, or any other, LANG appliance must be
performed by qualified personnel only. Consult your
authorized service station directory or call the factory at
1-800-224-LANG (5264), or WWW.LANGWORLD.COM for
the service station nearest you.
WARNING:BOTH HIGH AND LOW VOLTAGES ARE PRESENT
INSIDE THIS APPLIANCE WHEN THE UNIT IS
PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE
REPLACING ANY PARTS, DISCONNECT THE UNIT
FROM THE ELECTRIC POWER SUPPLY.
CAUTION:USE OF ANY REPLACEMENT PARTS OTHER THAN
THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED
DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE
OPERATOR AND DAMAGE TO THE EQUIPMENT AND
WILL VOID ALL WARRANTIES.
3
EQUIPMENT DESCRIPTION
GAS GRIDDLE
EXTERIOR
♦ Griddle
¾ The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on
the actual model number.
¾ The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows
closer installation to combustible surfaces.
¾ The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
♦AGC Hood
¾ The Hood dimension (not including griddle) are 19 1/2” (49.5cm) High with hood down, 38 3/8”
(97.5cm) High with hood up, 36 7/8” (93.5cm) Deep, and 23 7/8” (58.6cm) Wide.
¾ The Hood wrap is constructed of stainless steel and uses infrared heat to broil the product.
CONTROLS
The Gas Griddle is available either with the Lang Accu-Temp controls (G-2TI, G-3TI, G-4TI, G-5TI, G6TI), the Lang Accu-Temp Direct Spark controls (G-2TDSI, G-3TDSI, G-4TDSI, G-5TDSI, G-6TDSI), the
Lang Selectronic controls (G-2EI, G-3EI, G-4EI, G-5EI, G-6EI,), and the Lang Selectronic Direct Spark
controls (G-2EDSI, G-3EDSI, G-4EDSI, G-5EDSI, G-6EDSI):
♦ G-TI (Thermostatic ignition)
¾ Each twelve-inch section has its own easy to use manual thermostat with a temperature range from
175°F to 450°F in 50° increments.
¾ Each twelve-inch section has it’s own individual burner for high efficiency, quick recovery and
outstanding performance.
♦ G-TDSI (Direct Spark, Thermostatic ignition)
¾ Same dependable control features as the G-TI with the convenience of the direct spark ignition
system.
♦ G-EI (Electronic ignition)
¾ Each twelve-inch section has its own temperature selector switch that snaps into place to lock in
any temperature from 175°F to 450°F in 25° increments.
¾ Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can
sense and react to a temperature change of +/- 4°F.
¾ Each twelve-inch section has it’s own individual burner for high efficiency, quick recovery and
outstanding performance.
♦ G-EDSI (Direct Spark, Electronic ignition)
¾ Same great control features as the G-EI with the convenience of the direct spark ignition system.
4
INSTALLATION
RECEIVING THE GRIDDLE
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight
bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage, which
does not become apparent until the merchandise has been unpacked.
If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's
agent within 15 days of delivery. All packing material should be kept for inspection.
Do not return damaged merchandise to Lang Manufacturing Company. File your claim with the carrier.
Prior to un-crating, move the griddle as near its intended location as practical. The crating will help protect the unit
from the physical damage normally associated with moving it through hallways and doorways.
ELECTRICAL CONNECTION
The griddle is supplied with a cord and plug. The receptacle is not provided with the griddle.
Follow the receptacle manufacturer’s instructions when connecting the receptacle to the power supply.
GAS CONNECTION
This griddle is manufactured for use with the type of gas indicted on the nameplate. Contact the factory if your type
of gas does not match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal Gas Codes
ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a 3/4 inch or larger
gas supply line.
Remove the 5/16 inch nuts securing the rear of burners. These nuts are for securing the main burners during
transportation only. The rear burner shield must be removed to gain access to the nuts.
A pressure regulator for the type of gas specified is supplied with each appliance.
This regulator must be installed in the gas supply line. (Note the direction of the gas flow arrow.) The pressure in
the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with
the appliance operating at full fire. A 1/8 inch NPT tap is provided in the manifold for connecting a manometer.
Correct manifold pressures are:
5 inches water column for natural gas
10 inches water column for propane
When replacing the plug in the manifold, a pipe joint compound or sealant should be used that is resistant to the
action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Lang Manufacturing Company.
After the griddle is in its final position, adjust the legs to create 1/4 inch slant from back to front. This will allow the
grease to run into the grease gutter and provide the proper combustion air for the burners.
5
GAS GRIDDLE
1) Verify connections at plug and terminal block
2) Incoming Volt - Single Phase L1______
3) Gas pressure is set for 4.5” WC (Natural Gas), 9” WC (Propane).
Ensure that the regulator is installed in the correct direction.
4) Ensure Griddle body is tilted 1/8” lower in front. Confirm there is
4” clearance below Griddle.
5) Ensure that burner flame is stable and not lifting off of burner.
Flame should light around the “U” of each burner with no hesitation.
Height of flame should be 1 1/4” to 1 1/2” from burner surface.
Flames must not lift off of burner ports.
START-UPS
6) Ensure that spark electrode does not continue to spark after ignition.
The tip of the spark electrode and sensor electrodes must have flame
on them and glowing red.
7) Verify actual temperature at 350 °F ________ °F.
Note: Install thermocouple wire in center of 12” section for that
control area. Let griddle cycle off and on 3 times before recording
temperature.
Model #_______ Date_______ Serial #________
Store #___________ Tech Name___________________
Contact_______________ Company _________________________
Store Phone #___________ Service Company Phone #______________
ACV = Automatic Cut-off Valve
A = 1” Pipe
B = Reduction to ¾” Pipe
C = Reduction to ½” Pipe
D = Increase to ¾” Pipe
O = Optional Second AGC Parts
7
GENERAL
GENERAL
The suggested time and temperature chart (below) is provided as a guide for the products
listed only.
CAUTION:ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE
FROM COMBUSTIBLE MATERIALS.
CAUTION:KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND
DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO
AVOID THE DANGER OF SLIPS OR FALLS.
SUGGESTED TIMES AND TEMPERATURES WITHOUT AGC
HOOD
PRODUCTS
HAMBURGER
2 patties per LB 350 6 to 8
4 patties per LB 350 4 to 6
6 patties per LB 350 3 to 4
STEAKS
1/2 to 3/4 inch thick, cooked medium 375 5 to 7
3/4 to 1 inch thick, cooked medium 375 8 to 10
Lamb Chops 350 6 to 8
Pork Chops 350 6 to 8
Salmon 350 6 to 8
Halibut 325 6 to 8
Snapper 325 6 to 8
Hashbrown Potatoes 375 3 to 4
Bacon 350 3 to 4
Sausage Links or Patties 350 3 to 4
Ham (Pre-cooked) 375 2
Eggs 275 2 to 4
Note: The times and temperatures in this chart are intended as a general guide and starting point. Your
actual times and temperatures may vary from this chart.
If different temperature settings are to be used, select one side of the griddle and
operate at the lowest temperature. Adjoining sections should be set at
progressively higher temperatures. Do not try to operate the end sections hot and
the center sections cool.
TEMPERATURE
(F)
350
TIME (MIN)
8
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.