Lang 224ZS, 236ZS, 260ZS, 272ZS, 224ZSD Installation And Operation Instructions Manual

...
Page 1
ENVIROZONE SELECTRONIC
GAS GRIDDLE
Commercial
224ZS, 236ZS, 248ZS, 260ZS, 272ZS
224ZSD, 236ZSD, 248ZSD, 260ZSD, 272ZSD
Installation and
Operation
2M-W2014 Rev. A 5/20/14
IL2810
236ZS
Page 2
SAFETY SYMBOL
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE
APPLICABLE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION
SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN
OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION
& MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change speci cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Lang Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the speci cations. By using the information provided, the user assumes all risks in con- nection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial number, voltage and purchase & Installation Information in the area below and have it ready when you call to ensure a faster service.
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
Page 3
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at (314) 678-6315
TABLE OF CONTENTS
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 3
Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . 4
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation
Ventilation & Clearence . . . . . . . . . . . . . . . . . . . . . . 5
Leg Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical & Gas Connection. . . . . . . . . . . . . . . . . . . . 6
Initial Start-Up
Initial Lighting Procedure . . . . . . . . . . . . . . . . . . . . . 8
Seasoning Cooking Surface . . . . . . . . . . . . . . . . . . . . 8
Operation
Setting the Griddle Temperature . . . . . . . . . . . . . . . . . 9
Suggested Times and Temperatures . . . . . . . . . . . . . . . 9
Loading the Griddle . . . . . . . . . . . . . . . . . . . . . . . . 10
Sequence of Operation
Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance
Griddle Care (Chrome Surfaces) . . . . . . . . . . . . . . . . .11
Daily Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Weekly Cleaning . . . . . . . . . . . . . . . . . . . . . . . . .12
Burner Air Shutter Adjustment . . . . . . . . . . . . . . . . . . . 12
Troubleshooting
Symptoms / Possible Causes . . . . . . . . . . . . . . . . . . . 13
Possible Causes / Test . . . . . . . . . . . . . . . . . . . . . .14
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . 16-27
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
NOTICE ServiceonthisoranyotherLangappliancemustbeperformedbyqualied
personnel only. Consult your Lang Authorized Service Agent Directory. You can call our tech service number (314) 678-6315 or visit our website WWW.LANGWORLD.COM for the service agent nearest you.
1
Page 4
16.5”
20.5”
31.4”
TOP
FRONT SIDE
W
4”
IL2811
EQUIPMENT SPECIFICATIONS
Model
224ZS
236ZS
248ZS
260ZS
272ZS
Height x Width x Depth*
(Not including legs)
Clearance from
combustible surface
16.4” x 24.1” x 30.4”
418mm x 613mm x 773mm 110 kg 127 kg
16.4” x 36.1” x 30.4” 368 lbs. 420 lbs.
418mm x 917mm x 773mm 167 kg 191 kg
16.4” x 48.1” x 30.4” 448 lbs. 520 lbs.
418mm x 1222mm x 773mm 204 kg 236 kg
Sides: 5”, Back: 5”
16.4” x 60.1” x 30.4” 556 lbs. 635 lbs.
418mm x 1527mm x 773mm 253 kg 289 kg
16.4” x 72.1” x 30.4” 689 lbs. 800 lbs.
418mm x 1832mm x 773mm 313 kg 364 kg
Weight
Actual Shipping
243 lbs. 280 lbs.
*= For units with a 30” Deep Griddle surface, add 7” to the overall depth of the unit.
Freight
Class
65
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
2
Page 5
EQUIPMENT SPECIFICATIONS continued
SPECIFICATIONS
Model
224ZS-NAT X
224ZS-LP X 10 WC
236ZS-NAT X 5 WC
236ZS-LP X 10 WC
248ZS-NAT X 5 WC
248ZS-LP X 10 WC
260ZS-NAT X 5 WC
260ZS-LP X 10 WC
272ZS-NAT X 5 WC
272ZS-LP X 10 WC
NAT.
Gas
LP
Gas
Burner
Input
27000
BTU/hr
Manifold Gas Connection (3/4” NPT)
5 WC
1
54,000 BTU/hr
81,000 BTU/hr
108,000 BTU/hr
135,000 BTU/hr
162,000 BTU/hr
Electrical Requirments
Voltage
115V/60Hz 0.5 1 2.0
Total
kW
Phase
Amps /
Line
Model
224ZSD-NAT X
224ZSD-LP X 10 WC
236ZSD-NAT X 5 WC
236ZSD-LP X 10 WC
248ZSD-NAT X 5 WC
248ZSD-LP X 10 WC
260ZSD-NAT X 5 WC
260ZSD-LP X 10 WC
272ZSD-NAT X 5 WC
272ZSD-LP X 10 WC
NAT.
Gas
LP
Gas
Burner
Input
35000
BTU/hr
Manifold Gas Connection (3/4” NPT)
5 WC
70.000 BTU/hr
105,000 BTU/hr
140,000 BTU/hr
1
175,000 BTU/hr
210,000 BTU/hr
Electrical Requirments
Voltage
115V/60Hz 0.5 1 2.0
Total
kW
Phase
Amps /
Line
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
3
Page 6
EQUIPMENT DESCRIPTION
Main Power Switch
Grease Drawer
Legs
Gutter
Section
Temp. Dial
Section
Power Switch
1” Griddle Surface
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer installation to combustible surfaces.
The stainless steel drop-down door keeps the controls cool and control area clean.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery problems, warping, and ensure even heat to the edges of the griddle.
Controls
The Selectronic Griddle comes with the solid state controls which include:
• A Main Power Switch & Power Indicator for the entire unit.
• Each twelve-inch section has its own temperature selector switch that snaps into place to lock in any temperature from 175°F to 450°F (79°C to 232°C) in 25° increments.
• Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense and react to a temperature change of +/- 4°F.
Technical
• Griddle operates on either Natural gas or Propane. This must be specied when ordering. It is shipped with a Power Cord and Plug attached.
• Floor space required is 30” (76.20cm) Deep, and width is 2 ft, 3ft, 4ft, 5ft, or 6ft depending on actual model number.
• The griddle weighs 260, 390, 520, 650, 780 lbs. depending on actual model number.
GriddleGasandVoltageSpecications
The Lang Model can be connected to any 120 Volt source. The gas and electrical specications are listed in the table on the previous page.
NOTICE The data plate is on the right side of the griddle. The oven voltage,
wattage,serialnumber,wiresize,andclearancespecicationsare
on the data plate. This information should be carefully read and understood before proceeding with the installation.
4
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 7
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier’s agent. Concealed loss or damage means it does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier’s agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged
merchandise to Star Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the straps and remove the wood frame.
The oven can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
VENTILATION & CLEARENCE
CLEARANCE
For use on non-combustible countertops only. Combustible and non-combustible material must be at least 48” (120cm) from the top of the appliance and 5” (150mm) from the sides and back. Adequate clearance should also be provided for proper operation and servicing.
AIR SUPPLY
Make certain not to obstruct the  ow of combustion and ventilation air. Provisions for adequate air supply must be furnished. The legs supplied with the unit must be installed. Make certain that air intake openings in the bottom of the appliance are not obstructed. They are essential for proper combustion and operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided over the griddle to carry off fumes and gases. However, the unit should not be directly connected to a  ue or stack.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
5
Page 8
INSTALLATION
Leg Installation
There are four, adjustable legs provided for Enviro-Zone griddles.
The legs are shipped in the grease drawer(s) of the griddle. Install them into the threaded holes on the underside of the griddle body.
Leveling adjustment may be done by screwing the bottom portion of the leg in and out.
Electrical Connection
The griddle is supplied with a cord and plug. The receptacle is not provided with the griddle.
Follow the receptacle manufacturer’s instructions when connecting the receptacle to the power supply.
Gas Connection
This griddle is manufactured for use with the type of gas indicted on the nameplate. Contact the factory if your type of gas does not match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal Gas Codes ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a 3/4 inch or larger gas supply line.
Remove the 5/16 inch nuts securing the rear of burners. These nuts are for securing the main burners during transportation only. The rear burner shield must be removed to gain access to the nuts.
A pressure regulator for the type of gas specied is supplied with each appliance.
This regulator must be installed in the gas supply line. (Note the direction of the gas ow arrow.) The pressure in the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with the appliance operating at full re. A 1/8 inch NPT tap is provided in the manifold for connecting a manometer.
Correct manifold pressures are: 5 inches water column for natural gas 10 inches water column for propane
When replacing the plug in the manifold, a pipe joint compound or sealant should be used that is resistant to the action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Lang Manufacturing.
After the griddle is in its nal position, adjust the legs to create 1/8 inch slant from back to front. This will allow the grease to run into the grease gutter and provide the proper combustion air for the burners.
Above: typical leg installation
IL2804
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
6
Page 9
INSTALLATION continued
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN
WARNING
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located inside the control compartment of each griddle.
Thegriddlevoltage,serialnumber,gasspecications,andclearance specicationsareonthedataplate.Thisinformationshouldbecarefullyread
and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood, grease extractors,
reextinguishersystems,mustconformtotheirapplicableNational,Stateand
locally recognized installation standards.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
7
Page 10
INITIAL START UP
Initial Lighting Procedure
Clean the preservative coating from the griddle plate and splash guard. Add a mild detergent to hot water and wash the griddle plate and splash guard. Rinse with a damp sponge and dry with a clean rag.
WARNING: BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO
TEST ALL JOINTS FOR GAS LEAKS.
• Plug the unit into a 115-volt power supply.
• Turn the ON-STANDBY toggle switch to ON.
• Set the temperature dials to the desired temperature.
• Turn the toggle switch to each section to ON.
• To turn the griddle off, simply turn the main toggle switch to STANDBY.
Seasoning the Griddle Plate (non chrome only)
• Set the temperature dials to 300°F (148°C).
• Observe the burners through the opening at the top of the control panel.
• When the burners go OFF, apply a thin coat of high-grade, non-salted vegetable oil to the griddle surface.
• Rub the oil into the griddle surface with the at side of a spatula or a towel.
• Recoat any dry spots that appear then wait two minutes and wipe off any excess oil.
• Repeat the seasoning process at 350°F (176°C) and at 400°F (204°C).
NOTICE: Duringtherstfewhoursofoperationyoumaynoticeasmall
amount of smoke coming off the griddle, and a faint odor from the smoke. This is normal for a new griddle and will disappear
aftertherstfewhoursofuse.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
8
Page 11
OPERATION
Setting the Griddle Temperature
The suggested time and temperature chart (below) is provided as a guide for the products listed only.
If different temperature settings are to be used, select one side of the griddle and operate at the lowest temperature. Adjoining sections should be set at progressively higher temperatures. Do not try to operate the end sections hot and the center sections cool.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF
CAUTION
SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
SUGGESTED TIMES AND TEMPERATURES
TEMPERATURE
PRODUCTS
HAMBURGER
2 patties per LB 6 to 8
4 patties per LB 4 to 6
6 patties per LB 3 to 4
(F / C) TIME (MIN)
350°F (176°C)
STEAKS
1/2 to 3/4 inch thick, cooked
medium
3/4 to 1 inch thick, cooked
medium 8 to 10
Lamb Chops
Pork Chops 6 to 8
Salmon 6 to 8
Halibut
Snapper 6 to 8
Hashbrown Potatoes 375°F (190°C) 3 to 4
Bacon
Sausage Links or Patties 3 to 4
Ham (Pre-cooked) 375°F (190°C) 2
Eggs 275°F (135°C) 2 to 4
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Note: The times and temperatures in this chart are intended as a general
guide and starting point. Your actual times and temperatures may vary from
this chart.
375°F (190°C)
350°F (176°C)
325°F (162°C)
350°F (176°C)
5 to 7
6 to 8
6 to 8
3 to 4
9
Page 12
OPERATION
Loading the Griddle
An understanding of how the griddle sections are controlled will be a valuable aid in loading your griddle.
Each 12 inch section of your griddle is independently controlled. The temperature control sensor is mounted under the griddle plate in the center of each cooking section.
If the product is loaded directly over the temperature sensor, that section will turn on and the burner will heat the entire cooking section. If the product is loaded to the side, front or back of the temperature sensor, the thermostat will react to the temperature change much slowly.
During slow periods with minimal loads, do not load directly over the thermostat sensors as this will unnecessarily turn the burners on and overheat the remainder of the section not being utilized.
Turn the product and continue cooking until it has reached its desired degree of doneness.
Remove the product from the griddle.
When reloading the griddle, rst use the griddle surface on which a previous load was not placed. This will insure you the proper griddle temperature.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 13
SEQUENCE OF OPERATION
Power On
When the griddle is connected to 115 Volt power, the spark module for each section starts sparking. While they are sparking the solenoid valve for the pilot burners are energized.
When the individual pilot burners ignite, and the pilot ame is veried, the spark module will stop sparking. Note: The pilot burners will remain lit until the griddle is removed from power or the gas is shut off.
When the main switch is turned on, 24 Volts is applied to the temperature control circuit.
When one of the individual section’s switch is turned on, it provides power to the circuit board for that section.
The operator can now set the temperature of that section by selecting it on the temperature dial.
When the temperature on the dial is set higher than the temperature of the griddle section the circuit board will generate a “Heat call”. This call (24 VAC Signal) goes to the solenoid valve opening the valve. The pilot burner ignites the main burner.
As the griddle section temperature increases the temperature sense probe resistance increases.
When the griddle section reaches the temperature set on the selector switch, the circuit board which monitors the probe resistance will turn off the heat call and there by close the gas valve.
When the griddle temperature drops below the set temperature the circuit board generates a new heat call and the sequence repeats.
MAINTENANCE & CLEANING
Griddle Care (Chromium Surfaces)
It takes very little time and effort to keep this Industrial Chromium griddle surface sparkling clean and performing at top efciency. DO NOT allow grease to accumulate as it will carbonize and become difcult to remove. To prevent this condition the following cleaning suggestions should be followed:
1. Remove excess grease and food regularly with a 4” (100mm) wide Razor Sharp type scraper and wipe surface with a damp cloth if desired.
2. Following the scraping, for end of the day cleaning, a damp cloth and a non-silicated, nonabrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with a clean wet cloth.
3. Follow steps 2 and 3 from Griddle Care (Non-Chromium Surfaces) above.
CAUTION
1. Never use pumice, griddle stones, or abrasives on a chromium surface.
2. Never strike a chromium griddle surface with a sharp instrument or spatula edge.
3. Never use steel wool.
4. Never use commercial liquid grill cleaner on the griddle surface.
5. Abusing surface voids the warranty.
CHROME GRIDDLE SURFACE LIMITED WARRANTY EXCLUSIONS
Your Chrome griddle has been designed to give you many years of cooking reliability and requires minimum maintenance to keep the chrome surface in its original condition. All Chrome griddle surfaces are warranted for a period of 5 years against manufacturing defects to the original owner from the date of installation. This limited warranty is void if it is determined by Lang Manufacturing or one of its authorized representatives that the chrome surface has been misused or abused or
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
subjected to the following situations:
1. Improperly installed.
2. Incorrect voltage applied to Chrome units allowing the surface to overheat and discolor.
3. The misuse of any instrument or tool which scratches or makes indentations in the surface which could cause the surface to peel, ake, or chip off.
4. The use of any chemical or abrasive cleaning solution, griddle brick, stone, screen or other cleaning products which could damage and affect the performance of the chrome surface.
5. The neglect of daily routine maintenance to the chromium surface.
Page 14
MAINTENANCE & CLEANING continued
Daily Cleaning (Non chrome only)
Empty the grease drawer daily or whenever it is 3/4 full. It is easily removed for washing.
Keep the griddle surface clean. After each cooking load, scrape the griddle surface to remove any carbonized grease.
Once a day or when necessary the non chrome griddle surface should be thoroughly cleaned and seasoned again. Use a griddle stone, griddle pad, or liquid cleaner. Rub with the grain of the metal, being careful not to scrape the splash guard.
Chrome griddle surfaces can be scraped with a 4” wide Razor Sharp scrapper and wipe surface with a damp cloth.
Following the scraping, a damp cloth and non-silicated, non-abrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with a clean wet cloth.
Weekly Cleaning (Non chrome only)
A mild detergent with water or one of the many commercial cleaners may be used.
Be sure to rinse thoroughly and coat the griddle with a thin lm of oil to prevent rusting, non-chrome surfaces only.
Clean the exterior of the appliance with hot water and a mild detergent to maintain a gleaming appearance.
Re-season the griddle plate after each cleaning, non-chrome surfaces only.
Burner Air Shutter Adjustment
The air shutters are pre-set at the factory. However, minor adjustments may be required in the eld to accommodate differences in gas and elevation.
To adjust the air shutters, loosen the set screw holding the air damper to the burner near the gas inlet.
Adjust the air mixture until the burner ame just ickers on the burner. “Lift-off” or yellow ame indicates improper shutter adjustment.
Periodically inspect and clean the air shutters to insure complete combustion.
Air Shutter
Set Screw
Burner
IL2813
WARNING: KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY
WARNING
OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
CAUTION: MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS
MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND
CAUTION
PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED.
NOTICE: Never leave a chlorine sanitizer in contact with stainless steel
surfaces longer than 10 minutes. Longer contact can cause corrosion.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
12
Page 15
TROUBLESHOOTING
Symptoms
The chart below is to assist in the troubleshooting of the griddle.
Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the items to be checked.
To test for a possible cause, refer to the TEST section (on the following page) and locate the Possible Cause then refer to test to identify test procedures.
SYMPTON POSSIBLE CAUSE
Entire griddle not lighting
Power indicator is not lit
Section will not heat
Product burning
Product under done
Doesn’t ignite
• Failed regulator or plugged regulator vent
• Failed transformer
• No power to cord outlet
• Griddle unplugged from outlet
• Failed power cord or plug
• Failed power switch
• Failed pilot light
• Failed gas valve
• Failed spark module
• Failed circuit board
• Failed temperature sensor
• Plugged pilot orice
• Product is cooked too long
• Failed temperature sensor
• Failed circuit board
• Failed temperature selector
• Open wire between selector and circuit board
• Failed temperature sensor
• Failed circuit board
• Failed temperature selector
• Incorrect Gas pressure
• Failed igniter
• Improper gas pressure
• No power
• Failed spark module
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
13
Page 16
TROUBLESSHOOTING CONT.
TESTS
POSSIBLE CAUSE TEST
Failed Regulator • Replace regulator
Failed transformer • Check transformer for correct voltage, replace as necessary
Failed power cord or plug • Check cord and plug for proper voltage
Failed power switch • Check switch for continuity across poles
Failed pilot light • Check for continuity across pilot light leads
Failed gas valve
Failed igniter • Replace as necessary
Failed spark module • Check for correct incoming voltage at module
Failed circuit board • Check for proper voltage and operation
Failed temperature sensor • Ohm sensor for correct resistance
Failed temperature selector • Remove the wires and check the resistance on all settings
Open wire between selector and circuit board
Incorrect gas pressure • Adjust to correct pressure
Plugged regulator vent, or orice • Clean as necessary
• Remove the wires from the valve terminals and check for continuity across the coil
• Replace as necessary
NOTICE: Service on this, or any other, LANG appliance must be performed by
qualiedpersonnelonly.ConsultyourLANGauthorizedserviceagent
directory or call the factory at (314) 678-6315, or WWW.LANGWORLD.COM For the service agent nearest you.
BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS
APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE
WARNING
UNIT FROM THE ELECTRIC POWER SUPPLY.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED
BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND
CAUTION
WILL VOID ALL WARRANTIES.
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
14
Page 17
DR
PART NO.
2M-61122-W64
W/D - 236ZS GRIDDLE (NO TIMERS)
MODEL NO.
MATERIAL
REV. DATE/ECO DESCRIPTION OF CHANGE
TITLE
REVISIONS
3/25/14 :
DATE
CK.
ADAMS :
DR
TOLERANCE: UNLESS NOTED: .xxx ± .015
FINISH
# 10 SUNNEN DRIVE
LANG MANUFACTURING
ST. LOUIS, MO. 63143, USA
ANGLES ± 1 °
1
GRN
120V
BLK
BLK
WHT
GRN
WHT
WHT
8
2
BLK
WHT
BLK
8
9
BLK
WHT
14
24V
BLU
YEL
RED
BLK
1
2
RED
BLK
5
6
7
8
10
9
YEL
RED
BLK
WHT
BLK
WHT
6
4
1
2
5
3
YEL
RED
6
ORG
YEL
7
BRN
13
12
YEL
5
ORG
BLU
NO
COM
BRN
WHT
GRN
33
1 2 3 4
11
5
4
RED
13
RED
1
2
YEL
ORG
BLU
NO
RED
1
BLK
5
6
7
8
9
2 3 4
11
5
10
GRN
WHT
YEL
RED
12
BLK
BRN
5
YEL
COM
BRN
4
RED
GRN
THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL TO STAR MFG. INT'L
INC. NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED
7
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
PILOT IGNITOR
PILOT IGNITION MODULE
BURNER SOLENOID
PILOT SOLENOID
POWER CORD
1
KEY:
ON/OFF SWITCH
2
RELAY
4
3
5
6
7
TEMP CONTROL BOARD
WIRE NUT
INDICATOR LAMP
8
9
10
12 POSITION SWITCH
CONTROL SWITCH
RTD
11
13
12
BLK
WHT
6
4
1
2
5
3
6
ORG
CAP UNUSED
CONNECTORS
TRANSFORMER
14
13
RED
BLU
ORG
1
2
RED
1
BLK
5
6
7
8
9
2 3 4
11
5
10
GRN
RED
12
YEL
BRN
5
NO
YEL
COM
BRN
YEL
4
15
Page 18
1
2
3
4
5
6
7
8
9
25
24
23
22
26
27
28
20
29
19
18
10
SEE DETAIL A
30
21
20
19
18
17
16
12
11
13
14
15
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Model: EnviroZone Gas Selectronic Griddle
SK2771, Rev. - 4/14/14
Page 19
32
42
43
44
41
31
35
37
36
40
39
38
33
33
34
45
46
47
Model: 236ZS EnviroZone Selectronic Gas
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
44
48
42
44
DETAIL A
49
50
51
52
54
53
44
SK2771, Rev. - 4/01/14
Page 20
PARTS LIST May 20, 2014, Rev. A
Model: 224ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
K9-141-201-123
1
K9-141-201-723 GRIDDLE PLATE ASSY 2’ ZSD 224ZSD
2 2E-41100-42 2 SENSOR EZONE SELECTRONIC
K9-141-486
3
K9-141-486-3 PROBE GUARD, ZSD SELECT 224ZSD 4 2C-20202-08 8 WSHR PLT 5/16 LOCK SPLIT 5 2C-20301-06 10 NUT HEX 5/16-18 PLTD
K9-141-171-3W2 6
K9-141-171-W2 GRIDDLE BURNER ASSY 224ZS
K9-141-161-3W1 7
K9-141-161-W1 224ZS 8 K9-141-182 0 BAFFLE BETWEEN BURNERS
K9-141-181 9
K9-141-186 BAFFLE UNDER BURNER-30”D 224ZSD
10
11 2A-72500-20 4 LEG 10.25 WITH ADJ HEX 12 2A-72901-34 AR LEG STD 2 OD X 24.625 13 2C-20301-40 8 NUT HEX ACORN LOCK 3/8-16S/S 14 2C-20105-20 8 SCREW SET 3/8-16X1/2 CUP POINT 15 72901-27 4 CASTER 5 ADJ 16 2E-Z12020 1 SWITCH-TOGGLE 2P ST 17 K9-141-232-2-W2 1 FRONT PNL WELD, RIGHT ZS 18 Z1-70-07-0343 3 SWITCH GUARD 19 2M-12-07-0038 3 LABEL ON & OFF 20 2I-05-07-0013 3 BOOT SWITCH 21 Y9-31601-09-1 1 PILOT LT 120V W/TIN CLIP 22 2R-70701-28 2 KNB BLK 1/4BUSH2SETSCW@90 23 2M-60301-29 1 PNLLBL SELCT SWTDIAL 450o 24 2M-60301-43 1 DIE CAST PLT LANG SATIN 25 K9-141-241-W9 1 FRONT PANEL-LEFT END 2FT 26 2E-30600-W14 2 RELAY 277VAC SPST 30A 27 2K-70801-07 6 SPACER SUPPORT 1/2LG 28 2E-30304-22 2 SWTCB175-450oFW/41100-13 29 2E-40101-W19 2 CIRBD SI TEMP CONTROL 30 2E-30303-18 2 SWTTOGON-OFFSPST1/4HP125V 31 2K-80100-20 1 MANIFLD FR 141 GRIDDLE 2’ 32 2K-70101-03 1 BRASTBEELBOW 1/4NPT-3/8CC 33 2K-70101-06 1 BRASTEE BRNCH 1/4NPTM-3/8
34
35 2J-80302-W1 1 IGNITOR ELECTRODE 36 2C-Z5883 10 10-24 X 1/2 FZA SCREW 37 K9-141-146 2 PROBE GUARD SUPPORT 38 2K-70101-51 1 BRASTBE ELBOW 1/4CCX1/4CC 39 M9-144-186 1 BRACKET-IGNITOR TUBE-CB 40 2F-80002-W19 1 TUBE - LIGHTER .25 DIA
K9-141-252-W1 K9-142-251 GREASE DRAWER-WELD ASSY 224ZSD
2V-80501-04 2V-80501-05 GAS REG 3/4X3/4 CLS II LP
1
2
2
1 GREASE DRAWER SLIDE WELD
2
1
1
GRIDDLE PLATE ASSY, 2’ ZS 224ZS
PROBE GUARD, ZS SELECT 224ZS
GRIDDLE BURNER ASSY-30”D 224ZSD
224ZSD
BAFFLE UNDER BURNER 224ZS
GREASE DRAWER-EZONE GRID 224ZS
GAS REG 3/4X3/4 CLS I NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 21
Model: 224ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
2A-45408 2A-80400-12 ORIFICE HOOD .0595 #53 224ZS-LP
41
42 2C-20102-08 12 SCRW PHD ST 8-32X.375 43 K9-141-156-W5 1 VALVE BRACKET LEFT 44 2C-20102-12 24 SCRW PHD ST 10-32X3/8 45 2K-45300 5 FITTING 3/8CC X 1/8NPT 46 2V-80502-W07 3 VALVE SOLENOID-1/8 NPT 47 2V-70402-06 1 VALVE PILOT 1/8NPTX1/4CC 49 2J-80300-W20 1 PILOT IGNITION CONTROL 50 2C-20102-04 2 SCRW PHD ST 8-32X.5 PLTD 51 K9-141-151-W1 1 PILOT IGN CNTL MOUNT ASSY 52 2E-31400-07 1 XFORMR120-208-240/24V40VA 53 K9-141-152-W2 1 24V XFMR BRACKET ASSY 54 2C-20301-11 2 NUT HEX 8-32 PLTD NI 2C-20602-04 2 TINNERMAN SPD NUT 1/8 DIA NI 2E-31107-02-W2 1 CORDSET 14/3 15A 120V 10’ NI 2K-Z4921 4 BURNER TUBE FLEX 3/8 OD NI 2K-Z6943 1 GAS LINE 1/4”D x 8”L NI 2M-61122-W64 AR WIRE DIAGRAM - 236ZS
2A-80404-29 ORIFICE - #51 BLACK 224ZSD-LP Y9-80400-18 ORIFICE HOOD .1065 #36 224ZSD-NAT 2A-W1185 ORIFICE FITTING - 90 DEG
2
ORIFICE-HOOD #42 GRID NAT 224ZS-NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 22
PARTS LIST May 20, 2014, Rev. A
Model: 236ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
K9-141-201-133
1
K9-141-201-733 GRIDDLE PLATE ASSY, 3’ ZSD 236ZSD
2 2E-41100-42 3 SENSOR EZONE SELECTRONIC
K9-141-486
3
K9-141-486-3 PROBE GUARD ZSD SELECT 236ZSD 4 2C-20202-08 12 WSHR PLT 5/16 LOCK SPLIT 5 2C-20301-06 14 NUT HEX 5/16-18 PLTD
K9-141-171-3W2 6
K9-141-171-W2 GRIDDLE BURNER ASSY 236ZS
K9-141-161-3W1 7
K9-141-161-W1 236ZS
K9-141-182 8
K9-141-187 236ZSD
K9-141-181 9
K9-141-186 BAFFLE UNDER BURNER-30”D 236ZSD
10
11 2A-72500-20 4 LEG 10.25 WITH ADJ HEX 12 2A-72901-34 AR LEG STD 2 OD X 24.625 13 2C-20301-40 8 NUT HEX ACORN LOCK 3/8-16S/S 14 2C-20105-20 8 SCREW SET 3/8-16X1/2 CUP POINT 15 72901-27 4 CASTER 5 ADJ 16 2E-Z12020 1 SWITCH-TOGGLE 2P ST 17 K9-141-246-W8 1 FRONT PNL WELD, RIGHT ZS 18 Z1-70-07-0343 4 SWITCH GUARD 19 2M-12-07-0038 4 LABEL ON & OFF 20 2I-05-07-0013 4 BOOT SWITCH 21 Y9-31601-09-1 1 PILOT LT 120V W/TIN CLIP 22 2R-70701-28 3 KNB BLK 1/4BUSH2SETSCW@90 23 2M-60301-29 3 PNLLBL SELCT SWTDIAL 450o 24 2M-60301-43 1 DIE CAST PLT LANG SATIN 25 K9-141-241-W9 1 FRONT PANEL-LEFT END 2FT 26 2E-30600-W14 3 RELAY 277VAC SPST 30A 27 2K-70801-07 9 SPACER SUPPORT 1/2LG 28 2E-30304-22 3 SWTCB175-450oFW/41100-13 29 2E-40101-W19 3 CIRBD SI TEMP CONTROL 30 2E-30303-18 3 SWTTOGON-OFFSPST1/4HP125V 31 2K-80100-21 1 MANIFLD FR 141 GRIDDLE 3’ 32 2K-70101-03 1 BRASTBEELBOW 1/4NPT-3/8CC 33 2K-70101-06 2 BRASTEE BRNCH 1/4NPTM-3/8
34
35 2J-80302-W1 2 IGNITOR ELECTRODE 36 2C-Z5883 18 10-24 X 1/2 FZA SCREW 37 K9-141-146 3 PROBE GUARD SUPPORT 38 2K-70101-51 2 BRASTBE ELBOW 1/4CCX1/4CC 39 M9-144-186 2 BRACKET-IGNITOR TUBE-CB 40 2F-80002-W19 2 TUBE - LIGHTER .25 DIA
K9-141-252-W1
K9-142-251 GREASE DRAWER -WELD ASSY 236ZSD
2V-80501-04
2V-80501-05 GAS REG 3/4X3/4 CLS II LP
1
3
3
1 GREASE DRAWER SLIDE WELD
1 BAFFLE BETWEEN BURNERS
3
1
1
GRIDDLE PLATE ASSY, 3’ ZS 236ZS
PROBE GUARD, ZS SELECT 236ZS
GRIDDLE BURNER ASSY-30”D 236ZSD
236ZSD
236ZS
BAFFLE UNDER BURNER 236ZS
GREASE DRAWER-EZONE GRID 236ZS
GAS REG 3/4X3/4 CLS I NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 23
Model: 236ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
2A-45408 2A-80400-12 ORIFICE HOOD .0595 #53 236ZS-LP
41
42 2C-20102-08 20 SCRW PHD ST 8-32X.375 43 K9-141-156-W5 2 VALVE BRACKET LEFT 44 2C-20102-12 31 SCRW PHD ST 10-32X3/8 45 2K-45300 8 FITTING 3/8CC X 1/8NPT 46 2V-80502-W07 5 VALVE SOLENOID-1/8 NPT 47 2V-70402-06 2 VALVE PILOT 1/8NPTX1/4CC
48
49 2J-80300-W20 2 PILOT IGNITION CONTROL 50 2C-20102-04 4 SCRW PHD ST 8-32X.5 PLTD 51 K9-141-151-W1 2 PILOT IGN CNTL MOUNT ASSY 52 2E-31400-07 1 XFORMR120-208-240/24V40VA 53 K9-141-152-W2 1 24V XFMR BRACKET ASSY 54 2C-20301-11 2 NUT HEX 8-32 PLTD
NI 2C-20602-04 2 TINNERMAN SPD NUT 1/8 DIA NI 2E-31107-02-W2 1 CORDSET 14/3 15A 120V 10’ NI 2K-Z4921 5 BURNER TUBE FLEX 3/8 OD NI 2K-Z6943 2 GAS LINE 1/4”D x 8”L NI 2M-61122-W64 AR WIRE DIAGRAM - 236ZS
2A-80404-29 ORIFICE - #51 BLACK 236ZSD-LP Y9-80400-18 ORIFICE HOOD .1065 #36 236ZSD-NAT 2A-W1185 ORIFICE FITTING - 90 DEG
K9-141-156-W4 K9-141-156-W6 VALVE BRACKET-SHORT RIGHT
3
2
ORIFICE-HOOD #42 GRID NAT 236ZS-NAT
VALVE BRACKET RIGHT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 24
PARTS LIST May 20, 2014, Rev. A
Model: 248ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
1
2 2E-41100-42 4 SENSOR EZONE SELECTRONIC
3
4 2C-20202-08 16 WSHR PLT 5/16 LOCK SPLIT 5 2C-20301-06 18 NUT HEX 5/16-18 PLTD
6
7
8
9
10
11 2A-72500-20 4 LEG 10.25 WITH ADJ HEX 12 2A-72901-34 AR LEG STD 2 OD X 24.625 13 2C-20301-40 8 NUT HEX ACORN LOCK 3/8-16S/S 14 2C-20105-20 8 SCREW SET 3/8-16X1/2 CUP POINT 15 2P-72901-33 4 CASTER 5 ADJ 16 2E-Z12020 1 SWITCH-TOGGLE 2P ST
17
18 Z1-70-07-0343 5 SWITCH GUARD 19 2M-12-07-0038 5 LABEL ON & OFF 20 2I-05-07-0013 5 BOOT SWITCH 21 Y9-31601-09-1 1 PILOT LT 120V W/TIN CLIP 22 2R-70701-28 4 KNB BLK 1/4BUSH2SETSCW@90 23 2M-60301-29 3 PNLLBL SELCT SWTDIAL 450o 24 2M-60301-43 1 DIE CAST PLT LANG SATIN 25 K9-141-241-W9 1 FRONT PANEL-LEFT END 2FT 26 2E-30600-W14 4 RELAY 277VAC SPST 30A 27 2K-70801-07 12 SPACER SUPPORT 1/2LG 28 2E-30304-22 4 SWTCB175-450oFW/41100-13 29 2E-40101-W19 4 CIRBD SI TEMP CONTROL 30 2E-30303-18 4 SWTTOGON-OFFSPST1/4HP125V 31 2K-80100-22 1 MANIFLD FR 141 GRIDDLE 4’ 32 2K-70101-03 2 BRASTBEELBOW 1/4NPT-3/8CC 33 2K-70101-06 2 BRASTEE BRNCH 1/4NPTM-3/8
34
35 2J-80302-W1 2 IGNITOR ELECTRODE 36 2C-Z5883 20 10-24 X 1/2 FZA SCREW 37 K9-141-146 4 PROBE GUARD SUPPORT 38 2K-70101-51 2 BRASTBE ELBOW 1/4CCX1/4CC 39 M9-144-186 2 BRACKET-IGNITOR TUBE-CB 40 2F-80002-W19 2 TUBE - LIGHTER .25 DIA
K9-141-201-143 K9-141-201-743 GRIDDLE PLATE ASSY, 4’ ZSD 248ZSD
K9-141-486 K9-141-486-3 PROBE GUARD, ZSD SELECT 248ZSD
K9-141-171-3W2 K9-141-171-W2 GRIDDLE BURNER ASSY 248ZS K9-141-161-3W1 K9-141-161-W1 248ZS K9-141-182 K9-141-187 BAFFLE BETWEEN BURNERS 30”D 248ZSD K9-141-181 K9-141-186 BAFFLE UNDER BURNER-30”D 248ZSD K9-141-252-W1 K9-142-251 GREASE DRAWER WELD ASSY 248ZSD
K9-141-232-2-W2 K9-141-232-6-W3 FRONT PNL WELD, CENTER ZS
2V-80501-04 2V-80501-05 GAS REG 3/4X3/4 CLS II LP
1
4
4
2 GREASE DRAWER SLIDE WELD
1
4
2
1
1
GRIDDLE PLATE ASSY, 4’ ZS 248ZS
PROBE GUARD, ZS SELECT 248ZS
GRIDDLE BURNER ASSY-30”D 248ZSD
248ZSD
BAFFLE BETWEEN BURNERS 248ZS
BAFFLE UNDER BURNER 248ZS
GREASE DRAWER-EZONE GRID 248ZS
FRONT PNL WELD, RIGHT ZS
GAS REG 3/4X3/4 CLS I NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 25
Model: 248ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
2A-45408 2A-80400-12 ORIFICE-HOOD .0595 #53 248ZS-LP
41
42 2C-20102-08 24 SCRW PHD ST 8-32X.375 43 K9-141-156-W5 2 VALVE BRACKET LEFT 44 2C-20102-12 40 SCRW PHD ST 10-32X3/8 45 2K-45300 10 FITTING 3/8CC X 1/8NPT 46 2V-80502-W07 6 VALVE SOLENOID-1/8 NPT 47 2V-70402-06 2 VALVE PILOT 1/8NPTX1/4CC
48
49 2J-80300-W20 2 PILOT IGNITION CONTROL 50 2C-20102-04 4 SCRW PHD ST 8-32X.5 PLTD 51 K9-141-151-W1 2 PILOT IGN CNTL MOUNT ASSY 52 2E-31400-07 1 XFORMR120-208-240/24V40VA 53 K9-141-152-W2 1 24V XFMR BRACKET ASSY 54 2C-20301-11 2 NUT HEX 8-32 PLTD NI 2C-20602-04 2 TINNERMAN SPD NUT 1/8 DIA NI 2E-31107-02-W2 1 CORDSET 14/3 15A 120V 10’ NI 2K-Z4921 6 BURNER TUBE FLEX 3/8 OD NI 2K-Z6943 GAS LINE 1/4”D x 8”L NI 2M-61122-W64 AR WIRE DIAGRAM - 236ZS
2A-80404-29 ORIFICE - #51 BLACK 248ZSD-LP Y9-80400-18 ORIFICE HOOD .1065 #36 248ZSD-NAT 2A-W1185 ORIFICE FITTING - 90 DEG
K9-141-156-W4 3 VALVE BRACKET RIGHT K9-141-156-W6 1 VALVE BRACKET-SHORT RIGHT
4
ORIFICE-HOOD #42 GRID NAT 248ZS-NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 26
PARTS LIST May 20, 2014, Rev. A
Model: 260ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
K9-141-201-153
1
K9-141-201-753 GRIDDLE PLATE ASSY, 5’ ZSD 260ZSD
2 2E-41100-42 5 SENSOR EZONE SELECTRONIC
K9-141-486
3
K9-141-486-3 PROBE GUARD, ZSD SELECT 260ZSD 4 2C-20202-08 20 WSHR PLT 5/16 LOCK SPLIT 5 2C-20301-06 22 NUT HEX 5/16-18 PLTD
K9-141-171-3W2 6
K9-141-171-W2 GRIDDLE BURNER ASSY 260ZS
K9-141-161-3W1 7
K9-141-161-W1 260ZS
K9-141-182 8
K9-141-187 BAFFLE-BETWEEN BURNERS 30”D 260ZSD
K9-141-181 9
K9-141-186 BAFFLE UNDER BURNER-30”D 260ZSD
10
11 2A-72500-20 4 LEG 10.25 WITH ADJ HEX 12 2A-72901-34 AR LEG STD 2 OD X 24.625 13 2C-20301-40 8 NUT HEX ACORN LOCK 3/8-16S/S 14 2C-20105-20 8 SCREW SET 3/8-16X1/2 CUP POINT 15 2P-72901-33 4 CASTER 5 ADJ 16 2E-Z12020 1 SWITCH-TOGGLE 2P ST
17
18 Z1-70-07-0343 6 SWITCH GUARD 19 2M-12-07-0038 6 LABEL ON & OFF 20 2I-05-07-0013 6 BOOT SWITCH 21 Y9-31601-09-1 1 PILOT LT 120V W/TIN CLIP 22 2R-70701-28 5 KNB BLK 1/4BUSH2SETSCW@90 23 2M-60301-29 4 PNLLBL SELCT SWTDIAL 450o 24 2M-60301-43 1 DIE CAST PLT LANG SATIN 25 K9-141-241-W9 1 FRONT PANEL-LEFT END 2FT 26 2E-30600-W14 5 RELAY 277VAC SPST 30A 27 2K-70801-07 15 SPACER SUPPORT 1/2LG 28 2E-30304-22 5 SWTCB175-450oFW/41100-13 29 2E-40101-W19 5 CIRBD SI TEMP CONTROL 30 2E-30303-18 5 SWTTOGON-OFFSPST1/4HP125V 31 2K-80100-23 1 MANIFLD FR 141 GRIDDLE 5’ 32 2K-70101-03 2 BRASTBEELBOW 1/4NPT-3/8CC 33 2K-70101-06 3 BRASTEE BRNCH 1/4NPTM-3/8
34
35 2J-80302-W1 3 IGNITOR ELECTRODE 36 2C-Z5883 28 10-24 X 1/2 FZA SCREW 37 K9-141-146 5 PROBE GUARD SUPPORT 38 2K-70101-51 3 BRASTBE ELBOW 1/4CCX1/4CC 39 M9-144-186 3 BRACKET-IGNITOR TUBE-CB 40 2F-80002-W19 3 TUBE - LIGHTER .25 DIA
K9-141-252-W1
K9-142-251 GREASE DRAWER-WELD ASSY 260ZSD
K9-141-232-2-W2
K9-141-232-5-W2 FRONT PNL WELD, CENTER ZS
2V-80501-04
2V-80501-05 GAS REG 3/4X3/4 CLS II LP
1
5
5
2 GREASE DRAWER SLIDE WELD
2
5
2
1
1
GRIDDLE PLATE ASSY, 5’ ZS 260ZS
PROBE GUARD, ZS SELECT 260ZS
GRIDDLE BURNER ASSY-30”D 260ZSD
260ZSD
BAFFLE BETWEEN BURNERS 260ZS
BAFFLE UNDER BURNER 260ZS
GREASE DRAWER-EZONE GRID 260ZS
FRONT PNL WELD, RIGHT ZS
GAS REG 3/4X3/4 CLS I NAT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 27
Model: 260ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
2A-45408 2A-80400-12 ORIFICE HOOD .0595 #53 260ZS-LP
41
42 2C-20102-08 32 SCRW PHD ST 8-32X.375 43 K9-141-156-W5 2 VALVE BRACKET LEFT 44 2C-20102-12 46 SCRW PHD ST 10-32X3/8 45 2K-45300 13 FITTING 3/8CC X 1/8NPT 46 2V-80502-W07 8 VALVE SOLENOID-1/8 NPT 47 2V-70402-06 3 VALVE PILOT 1/8NPTX1/4CC
48
49 2J-80300-W20 3 PILOT IGNITION CONTROL 50 2C-20102-04 6 SCRW PHD ST 8-32X.5 PLTD 51 K9-141-151-W1 3 PILOT IGN CNTL MOUNT ASSY 52 2E-31400-07 1 XFORMR120-208-240/24V40VA 53 K9-141-152-W2 1 24V XFMR BRACKET ASSY 54 2C-20301-11 2 NUT HEX 8-32 PLTD NI 2C-20602-04 2 TINNERMAN SPD NUT 1/8 DIA NI 2E-31107-02-W2 1 CORDSET 14/3 15A 120V 10’ NI 2K-Z4921 8 BURNER TUBE FLEX 3/8 OD NI 2K-Z6943 3 GAS LINE 1/4”D x 8”L NI 2M-61122-W64 AR WIRE DIAGRAM - 236ZS
2A-80404-29 ORIFICE - #51 BLACK 260ZSD-LP Y9-80400-18 ORIFICE HOOD .1065 #36 260ZSD-NAT 2A-W1185 ORIFICE FITTING - 90 DEG
K9-141-156-W4 K9-141-156-W6 VALVE BRACKET-SHORT RIGHT
5
3
ORIFICE-HOOD #42 GRID NAT 260ZS-NAT
VALVE BRACKET RIGHT
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 28
PARTS LIST May 20, 2014, Rev. A
Model: 272ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
K9-141-201-163
1
K9-141-201-763 GRIDDLE PLATE ASSY, 6’ ZSD 272ZSD
2 2E-41100-42 6 SENSOR EZONE SELECTRONIC
K9-141-486
3
K9-141-486-3 PROBE GUARD, ZSD SELECT 272ZSD 4 2C-20202-08 24 WSHR PLT 5/16 LOCK SPLIT 5 2C-20301-06 26 NUT HEX 5/16-18 PLTD
K9-141-171-3W2 6
K9-141-171-W2 GRIDDLE BURNER ASSY 272ZS
K9-141-161-3W1 7
K9-141-161-W1 242ZS
K9-141-182 8
K9-141-187 BAFFLE-BETWEEN BURNERS 30”D 272ZSD
K9-141-181 9
K9-141-186 BAFFLE UNDER BURNER-30”D 272ZSD
10
11 2A-72500-20 4 LEG 10.25 WITH ADJ HEX 12 2A-72901-34 AR LEG STD 2 OD X 24.625 13 2C-20301-40 8 NUT HEX ACORN LOCK 3/8-16S/S 14 2C-20105-20 8 SCREW SET 3/8-16X1/2 CUP POINT 15 2P-72901-33 4 CASTER 5 ADJ 16 2E-Z12020 1 SWITCH-TOGGLE 2P ST
17
18 Z1-70-07-0343 7 SWITCH GUARD 19 2M-12-07-0038 7 LABEL ON & OFF 20 2I-05-07-0013 7 BOOT SWITCH 21 Y9-31601-09-1 1 PILOT LT 120V W/TIN CLIP 22 2R-70701-28 6 KNB BLK 1/4BUSH2SETSCW@90 23 2M-60301-29 6 PNLLBL SELCT SWTDIAL 450o 24 2M-60301-43 1 DIE CAST PLT LANG SATIN 25 K9-141-242-W8 1 FRONT PANEL WELD, LEFT ZS 26 2E-30600-W14 6 RELAY 277VAC SPST 30A 27 2K-70801-07 9 SPACER SUPPORT 1/2LG 28 2E-30304-22 6 SWTCB175-450oFW/41100-13 29 2E-40101-W19 6 CIRBD SI TEMP CONTROL 30 2E-30303-18 6 SWTTOGON-OFFSPST1/4HP125V 31 2K-80100-24 1 MANIFLD FR 141 GRIDDLE 6’ 32 2K-70101-03 3 BRASTBEELBOW 1/4NPT-3/8CC 33 2K-70101-06 2 BRASTEE BRNCH 1/4NPTM-3/8
34
35 2J-80302-W1 2 IGNITOR ELECTRODE 36 2C-Z5883 18 10-24 X 1/2 FZA SCREW 37 K9-141-146 6 PROBE GUARD SUPPORT 38 2K-70101-51 2 BRASTBE ELBOW 1/4CCX1/4CC 39 M9-144-186 2 BRACKET-IGNITOR TUBE-CB 40 2F-80002-W19 2 TUBE - LIGHTER .25 DIA
K9-141-252-W1
K9-142-251 GREASE DRAWER-WELD ASSY 272ZSD
K9-141-237-W13
K9-141-246-W8 FRONT PANEL WELD, RIGHT ZS
2V-80501-04
2V-80501-05 GAS REG 3/4X3/4 CLS II LP
GRIDDLE PLATE ASSY, 6’ ZS 272ZS
1
PROBE GUARD, ZS SELECT 272ZS
6
GRIDDLE BURNER ASSY-30”D 272ZSD
6
1 GREASE DRAWER SLIDE WELD
BAFFLE BETWEEN BURNERS 272ZS
3
BAFFLE UNDER BURNER 272ZS
6
GREASE DRAWER-EZONE GRID 272ZS
2
FRONT PANEL, CENTER ZS
1
GAS REG 3/4X3/4 CLS I NAT
1
272ZSD
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 29
Model: 272ZS-NAT & LP EnviroZone Selectronic Gas Griddle
Fig No. Part No Qty Description Application
2A-45408 2A-80400-12 ORIFICE HOOD .0595 #53 272ZS-LP
41
42 2C-20102-08 36 SCRW PHD ST 8-32X.375 43 K9-141-156-W5 0 VALVE BRACKET LEFT 44 2C-20102-12 50 SCRW PHD ST 10-32X3/8 45 2K-45300 8 FITTING 3/8CC X 1/8NPT 46 2V-80502-W07 9 VALVE SOLENOID-1/8 NPT 47 2V-70402-06 2 VALVE PILOT 1/8NPTX1/4CC
48
49 2J-80300-W20 2 PILOT IGNITION CONTROL 50 2C-20102-04 4 SCRW PHD ST 8-32X.5 PLTD 51 K9-141-151-W1 2 PILOT IGN CNTL MOUNT ASSY 52 2E-31400-07 1 XFORMR120-208-240/24V40VA 53 K9-141-152-W2 1 24V XFMR BRACKET ASSY 54 2C-20301-11 2 NUT HEX 8-32 PLTD NI 2C-20602-04 2 TINNERMAN SPD NUT 1/8 DIA NI 2E-31107-02-W2 1 CORDSET 14/3 15A 120V 10’ NI 2K-Z4921 9 BURNER TUBE FLEX 3/8 OD NI 2K-Z6943 2 GAS LINE 1/4”D x 8”L NI 2M-61122-W64 AR WIRE DIAGRAM - 236ZS
2A-80404-29 ORIFICE - #51 BLACK 272ZSD-LP Y9-80400-18 ORIFICE HOOD .1065 #36 272ZSD-NAT 2A-W1185 ORIFICE FITTING - 90 DEG
K9-141-156-W4 4 VALVE BRACKET RIGHT K9-141-156-W6 5 VALVE BRACKET-SHORT RIGHT
ORIFICE-HOOD #42 GRID NAT 272ZS-NAT
6
2M-W2014: GAS ENVIROZONE SELECTRONIC GRIDDLE
Page 30
Page 31
Page 32
STAR INTERNATIONAL HOLDINGS INC. COMPANY
Star - Holman - Lang - Wells - Bloomeld - Toastmaster
10 Sunnen Drive, St. Louis, MO 63143 U.S.A.
(314) 678-6303
www.star-mfg.com