Lang 224THG, 224SHG, 224THE, 236T, 236THE Operation Manual

...
Installation,
Maintenance Instructions
Gas Griddle, Spark Ignition, “ACCU-TEMP”
Model:
224T 224TH 224THG 224SHG 224THE 236T 236THE 236THG 248T 248TC 248TCHE 248THE 248THG 260T 260TC 260TCHG 260THE 260THG 272T 272THG 272TNTS
Star Manufacturing International 10 Sunnen Drive St. Louis, MO 63143 Part Number: 2M-W358 Phone: 800-438-5264 Fax: 314-781-2714 Rev. F WWW.STAR-MFG.COM
October 14, 2010
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
POST IN A PROMINENT LOCATION
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IMPORTANT
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1/NFPA 54 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
Model #: Purchased From: Serial #: Location: Date Purchased: Date Installed: Purchase Order #: For Service, Call:
2
TABLE OF CONTENTS
CHAPTER PAGE
1. TABLE OF CONTENTS ...............................................................................3
2. READ FIRST .................................................................................................4
3. EQUIPMENT DESCRIPTION ...................................................................... 6
4. UNPACKING................................................................................................. 8
5. INSTALLATION ........................................................................................... 10
6. GRIDDLE SURFACE CARE ........................................................................ 11
7. CHROME WARRANTY ............................................................................... 12
8. INITIAL START-UP......................................................................................13
9. OPERATION...........................................................................................14 - 15
10. MAINTENANCE & CLEANING PROCEDURES...................................... 16
11. TROUBLESHOOTING ................................................................................. 18
12. PARTS LIST ........................................................................................... 19 - 24
13. WIRING DIAGRAMS............................................................................25 - 26
3
IMPORTANT READ FIRST IMPORTANT
CAUTION: THE GRIDDLE EXTREMELY HEAVY. FOR SAFE
HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION: ANY STAND, COUNTER OR OTHER DEVICE ON
WHICH THE GRIDDLE WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN
SNAP BACK WHEN CUT.
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING: INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located inside the control
compartment of each griddle. The griddle voltage, serial number, gas specifications, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent
hood, grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards.
WARNING: BEFORE LIGHTING, USE A SOAP AND WATER
SOLUTION TO TEST ALL JOINTS FOR GAS LEAKS.
NOTICE: During the first few hours of operation you may
notice a small amount of smoke coming off the griddle, and a faint odor from the smoke. This is normal for a new griddle and will disappear after the first few hours of use.
CAUTION: ALWAYS KEEP THE AREA NEAR THE APPLIANCE
FREE FROM COMBUSTIBLE MATERIALS.
4
IMPORTANT READ FIRST IMPORTANT
CAUTION: KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND
DRY. IF SPILLS OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
WARNING: KEEP WATER AND SOLUTIONS OUT OF CONTROLS.
NEVER SPRAY OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
CAUTION: MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES,
MUCOUS MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED.
NOTICE: Never leave a chlorine sanitizer in contact with stainless
steel surfaces longer than 10 minutes. Longer contact can cause corrosion.
CAUTION: GRILL CALIBRATION REQUIRES DISASSEMBLY OF
THE THERMOSTAT AND SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY. IT IS GENERALLY MORE COST EFFECTIVE TO REPLACE A THERMOSTAT THAT IS OUT OF CALIBRATION.
NOTICE: Service on this, or any other, LANG appliance must be
performed by qualified personnel only. Consult your LANG Authorized Service Agent Directory or call the factory at 1-800-807-9054, or WWW.STAR-MFG.COM For the service agent near you.
WARNING: BOTH HIGH AND LOW VOLTAGES ARE PRESENT
INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED/WIRED INTO A LIVE RECEPTACLE. BEFORE REPLACING ANY PARTS, DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY.
CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN
THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.
5
EQUIPMENT DESCRIPTION
Lang Model: 200 Series “AccuTemp” Griddles
3.1 Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and
width is dependent on the actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless
steel, which allows closer installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot
and cold spots, recovery problems, warping, and ensure even heat to the edges of the griddle.
3.2 Operation
Each twelve-inch section has its own snap-action thermostat and gas valves
that are fully on or fully off.
3.3 Controls
The ACCU-TEMP Griddle comes with thermostat controls.
3.4 Technical
Griddle operates on either Natural gas or Propane. This must be specified
when ordering. It is shipped with a Power Cord and Plug attached.
Floor space required is 30” (76.20cm) Deep, and width is 2 ft, 3ft, 4ft, 5ft, or
6ft depending on actual model number.
The griddle weighs 260, 390, 520, 650, 780 lbs. depending on actual model
number.
3.5 Griddle Gas and Voltage Specifications
AccuTemp Griddles can be connected to any 120 Volt source.
The gas and electrical specifications are listed in the table below
6
WEIGHT
SHIPPING
PRESSURE
REGULATOR
CORD/PLUG &
CLEARANCE FROM
COMBUSTIBLE SURFACES
SIDES BACK BOTTOM
EQUIPMENT DESCRIPTION CONT’D
ELECTRICAL CONNECTION
GAS AND ELECTRICAL INPUT REQUIREMENTS
TOTAL BTU INPUT
VOLTAGE AMPS
GAS CONNECTION
10” WC
PROPANE
5” WC
NATURAL
OF
GREASE
NUMBER
NUMBER
NUMBER OF
CONTROLS
OF
DRAWERS
7
BURNERS
SPECIFICATIONS AND INFORMATION
OF GRIDDLE
SQUARE INCHES
OVERALL
DESCRIPTION
224T 24 INCHES 54,000 54,000 ONE 3/4” NPT 115 VOLT 2 SUPPLIED
236T 36 INCHES 81,000 81,000 ONE 3/4” NPT 115 VOLT 2 SUPPLIED
248T 48 INCHES 108,000 108,000 ONE 3/4” NPT 115 VOLT 2 SUPPLIED
260T 60 INCHES 135,000 135,000 ONE 3/4” NPT 115 VOLT 2 SUPPLIED
MODEL
NUMBER
272T 72 INCHES 162,000 162,000 TWO 3/4” NPT 115 VOLT 2 SUPPLIED
GRILL SURFACE
WIDTH DEPTH
MODEL
NUMBER
224T 24 INCHES 23 INCHES 552 2 2 1 5 INCHES 5 INCHES 4 INCH LEG 260
236T 36 INCHES 23 INCHES 828 3 3 1 5 INCHES 5 INCHES 4 INCH LEG 390
248T 48 INCHES 23 INCHES 1104 4 4 1 5 INCHES 5 INCHES 4 INCH LEG 520
260T 60 INCHES 23 INCHES 1380 5 5 2 5 INCHES 5 INCHES 4 INCH LEG 650
272T 72 INCHES 23 INCHES 1656 6 6 2 5 INCHES 5 INCHES 4 INCH LEG 780
UNPACKING
4.1 Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage which does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing International. File your claim with the carrier.
4.2 Location
Prior to un-crating, move the griddle as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
4.3 Un-crating
The griddle will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid. Remove the cardboard cover, cut the
straps and remove the wood frame.
CAUTION: THE GRIDDLE EXTREMELY HEAVY. FOR SAFE
HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION: ANY STAND, COUNTER OR OTHER DEVICE ON WHICH
THE GRIDDLE WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN
SNAP BACK WHEN CUT.
Remove griddle from skid and place in intended location.
8
INSTALLATION
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH.
WARNING: INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located inside the control compartment of
each griddle. The griddle voltage, serial number, gas specifications, and clearance specifications are on the data plate. This information should be carefully read and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must conform to their applicable National, State and locally recognized installation standards.
5.1 Electrical Connection
The griddle is supplied with a cord and plug. The receptacle is not provided with the griddle.
All electrical receptacles must be wired by a licensed electrician and in accordance with local codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CSA STD. C221)
5.2 Gas Connection
This griddle is manufactured for use with the type of gas indicted on the nameplate. Contact the factory if your type of gas does not match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal Gas Codes ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a 3/4 inch or larger gas supply line.
Remove the 5/16 inch nuts securing the rear of burners. These nuts are for securing the main burners during transportation only. The rear burner shield must be removed to gain access to the nuts.
A pressure regulator for the type of gas specified is supplied with each appliance.
This regulator must be installed in the gas supply line. (Note the direction of the gas flow arrow.) The pressure in the manifold of the appliance should be tested with a manometer and the regulator adjusted for proper pressure with the appliance operating at full fire. A 1/8 inch NPT tap is provided in the manifold for connecting a manometer.
9
Loading...
+ 19 hidden pages