DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST
EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL
GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE
APPLICABLE.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION
SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN
OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION
& MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
These symbols are intended to alert the user to the presence of important operating
and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change speci cations and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the
specifications contained in this sheet are subject to change without notice. While Lang
Manufacturing exercises good faith efforts to provide information that is accurate, we are
not responsible for errors or omissions in information provided or conclusions reached as a
result of using the speci cations. By using the information provided, the user assumes all risks in con-
nection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at (314) 678-6315
personnel only. Consult your Lang Authorized Service Agent Directory.
You can call our tech service number (314) 678-6315 or visit our website
WWW.LANGWORLD.COM for the service agent nearest you.
3
16.4”
4.0”
20.4”
30.4”
W”
Top
FrontSide
IL1577
EQUIPMENT SPECIFICATIONS
Model
224S
236S
248S
260S
272S
Height x Width x DepthClearance from Weight
16.4” x 24.1” x 30.4”243 lbs.280 lbs.
418mm x 613mm x 773mm110 kg127 kg
16.4” x 36.1” x 30.4”368 lbs.420 lbs.
418mm x 917mm x 773mm167 kg191 kg
16.4” x 48.1” x 30.4”Sides: 5”448 lbs.520 lbs.
418mm x 1222mm x 773mmBack: 5”204 kg236 kg
16.4” x 60.1” x 30.4”556 lbs.635 lbs.
418mm x 1527mm x 773mm253 kg289 kg
16.4” x 72.1” x 30.4”689 lbs.800 lbs.
418mm x 1832mm x 773mm313 kg364 kg
Freight
Class(Not including legs)combustible surfaceActualShipping
NAT.Gas LP. Gas Burner InputManifold Press. Gas Connection (3/4” NPT)VoltageTotal kW Phase Amps /Line
Gas RequirementsElectrical Requirments
5 WC
115V/60Hz0.5
50,000 BTU/hr
81,000 BTU/hr
115V/60Hz0.52.0
1
27,000
108,000 BTU/hr
135,000 BTU/hr
115V/60Hz0.52.0
2162,000 BTU/hr
2.0224SC-NATX5 WC
1
5
EQUIPMENT DESCRIPTION
1” Griddle Surface
Panel Cover Removed for Clarity
Gutter
Legs
Section
Temp. Dial
Section
Power Switch
Grease
Pan
Power
Indicator
Main
Power
Switch
IL1575
Gas
Regulator
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the
actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer
installation to combustible surfaces.
The stainless steel drop-down door keeps the controls cool and control area clean.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
Controls
The Selectronic Griddle comes with the solid state controls which include:
• A Main Power Switch & Power Indicator for the entire unit.
• Each twelve-inch section has its own temperature selector switch that snaps into place to lock in
• Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can
Technical
• Griddle operates on either Natural gas or Propane. This must be specied when ordering. It is
• Floor space required is 30” (76.20cm) Deep, and width is 2 ft, 3ft, 4ft, 5ft, or 6ft depending on actual
• The griddle weighs 260, 390, 520, 650, 780 lbs. depending on actual model number.
GriddleGasandVoltageSpecications
The Lang Model can be connected to any 120 Volt source. The gas and electrical specications are
listed in the table on the previous page.
NOTICE The data plate is on the right side of the griddle. The oven voltage,
any temperature from 175°F to 450°F (79°C to 232°C) in 25° increments.
sense and react to a temperature change of +/- 4°F.
on the data plate. This information should be carefully read and
understood before proceeding with the installation.
6
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery and
signed by the carrier’s agent. Concealed loss or damage means it does not
become apparent until the merchandise has been unpacked. If concealed
loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier’s agent within 15 days of delivery. All packing
material should be kept for inspection. Do not return damaged
merchandise to Star Manufacturing Company. File your claim with the
carrier.
Location
Prior to un-crating, move the oven as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid.
Cut the straps and remove the wood frame.
The oven can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK)
TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH OVEN WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
VENTILATION & CLEARENCE
CLEARANCE
For use on non-combustible countertops only.
Combustible and non-combustible material must be at least 48” (120cm) from the top of the
appliance and 5” (150mm) from the sides and back. Adequate clearance should also be provided
for proper operation and servicing.
AIR SUPPLY
Make certain not to obstruct the ow of combustion and ventilation air. Provisions for adequate air
supply must be furnished. The legs supplied with the unit must be installed. Make certain that air
intake openings in the bottom of the appliance are not obstructed. They are essential for proper
combustion and operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided over the griddle to carry off fumes and gases. However,
the unit should not be directly connected to a ue or stack.
7
INSTALLATION
Electrical Connection
The 120V griddles are supplied with a cord and plug, 240V units are not. The 120V receptacle is not
provided with the griddle.
Follow the receptacle manufacturer’s instructions when connecting the receptacle to the power supply.
Gas Connection
This griddle is manufactured for use with the type of gas indicted on the nameplate.
Contact the factory if your type of gas does not match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal
Gas Codes ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a
3/4 inch or larger gas supply line.
Remove the 5/16 inch nuts securing the rear of burners. These nuts are for securing the main burners
during transportation only. The rear burner shield must be removed to gain access to the nuts.
A pressure regulator for the type of gas specied is supplied with each appliance.
This regulator must be installed in the gas supply line. (Note the direction of the gas ow arrow.)
The pressure in the manifold of the appliance should be tested with a manometer and the regulator
adjusted for proper pressure with the appliance operating at full re. A 1/8 inch NPT tap is provided in
the manifold for connecting a manometer.
Correct manifold pressures are:
5 inches water column for natural gas
10 inches water column for propane
When replacing the plug in the manifold, a pipe joint compound or sealant should be used that is
resistant to the action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Star Manufacturing
International.
After the griddle is in its nal position, adjust the legs to create 1/8 inch slant from back to front.
This will allow the grease to run into the grease gutter and provide the proper combustion air for the
burners.
DANGER: THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL
PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD
RESULT IN ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING.
WARNING
IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL
AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located inside the control compartment of each
applicable National, State and locally recognized installation
standards.
8
INITIAL START UP
Initial Lighting Procedure
Clean the preservative coating from the griddle plate and splash guard. Add a mild detergent to hot
water and wash the griddle plate and splash guard. Rinse with a damp sponge and dry with a clean
rag.
WARNING: BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO
TEST ALL JOINTS FOR GAS LEAKS.
• Plug the unit into a power supply that matches what is listed on the nameplate.
• Turn the ON-STANDBY toggle switch to ON.
• Set the temperature dials to the desired temperature.
• Turn the toggle switch to each section to ON.
• To turn the griddle off, simply turn the main toggle switch to STANDBY.
Seasoning the Griddle Plate (non chrome only)
• Set the temperature dials to 300°F (148°C).
• Observe the burners through the opening at the top of the control panel.
• When the burners go OFF, apply a thin coat of high-grade, non-salted vegetable oil to the
griddle surface.
• Rub the oil into the griddle surface with the at side of a spatula or a towel.
• Recoat any dry spots that appear then wait two minutes and wipe off any excess oil.
• Repeat the seasoning process at 350°F (176°C) and at 400°F (204°C).