alteration, service or maintenance can cause
property damage, injury or death. Read
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY: Do not store or use
gasoline or other ammable vapors or liquids
in the vicinity of this or any other appliance.
Retain This Manual for Future Reference.
WARNING: This appliance shall be installed
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local
gas supplier.
1
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase or 3 Phase:
Purchased From:
Location:
Purchase Date:
Installed Date:
These symbols are intended to alert the user to the presence of important operating
and maintenance instructions in the manual accompanying the appliance.
FOR YOUR SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST
EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL
GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE
APPLICABLE.
POST IN PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS INFORMATION
SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER. AS A MINIMUM, TURN
OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT.
EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATION
& MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change speci cations and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the
specifications contained in this sheet are subject to change without notice. While Lang
Manufacturing exercises good faith efforts to provide information that is accurate, we are
not responsible for errors or omissions in information provided or conclusions reached as a
result of using the speci cations. By using the information provided, the user assumes all risks in con-
nection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 314-678-6315.
NOTICE Service on this or any other Lang appliance must be performed by
qualied personnel only.
Consult your Lang Authorized Service Agent Directory.
You can call our toll free number 314-678-6315 or
visit our website www.langworld.com for the service agent nearest you.
3
SPECIFICATIONS
36"
(913)
4"
(102)
16.5/8"
(422)
3"
(77)
3.3/16"
(81)
23"
(584)
4"
(102)
ELECTRICAL
CONNECTION
5.1/2.FT.CORD
Front View/ElevationTop View/Plan
IL1826a
Model
2124ZRCB
2136ZRCB
2148ZRCB
2160ZRCB
2172ZRCB
* Noncombustible oor only
Model
2124ZRCB
2136ZRCB
2148ZRCB
2160ZRCB
2172ZRCB
Height x Width x DepthClearance fromWeight
(Not Including legs)combustible surface*ActualShipping
10-58” X 24” X 28-5/8”
422mm x 610mm x 727mm75 kg91 kg
10-5/8” x 36” x 28-5/8”225 lbs.265 lbs.
422mm x 914mm x 727mm102 kg120 kg
10-5/8” x 48” x 28-5/8”300 lbs285 lbs
422mm x 1219mm x 727mm136 kg130 kg
10-5/8” x 60” x 28-5/8”385 lbs.430 lbs.
422mm x 1524mm x 727mm175 kg195 kg
10-5/8” x 72” x 28-5/8”470 lbs520 lbs
422mm x 1829mm x 727mm214 kg236 kg
Gas Requirement (3/4” NPT)
EQUIPMENT SPECIFICATIONS
GAS CHEFSERIES CHARBROILER
64,000 BTU/hr
96,000 BTU/hr
128,000 BTU/hr
160,000 BTU/hr
192,000 BTU/hr
Sides & Back: 4”
165 lbs.200 lbs.
Fright Class
65
65
65
65
65
4
EQUIPMENT DESCRIPTION
Hinged
Front.Panel
Grease.Pan
Nameplate
12”.Section.Knob
Lighting
Instructions
On/Off.Switch
4”.Adj .Legs.Standard
(Legs.&.Casters.Optional)
Gas.Inlet
Wall.
Mounting
Power.Cord
Grease.Trough
Grates
Front
IL1884
5
CAUTION
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor
for use directly by the general public in food service locations.
The Lang series gas charbroiler is equipped for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped from the factory for use with natural gas.
The unit can easily be converted for use with propane gas: see propane gas.
-IMPORTANTBe sure to remove all paper protection and packing material from unit prior to
lighting.
INSTALL IN NON-COMBUSTIBLE LOCATIONS ONLY! Clearance from noncombustible construction must be 4" minimum from back and sides. For servicing,
6" is recommended from back of unit.
The installation of the Appliance must conform to the NATIONAL FUEL GAS
CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY
RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE
CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR
CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES
WHERE APPLICABLE.
NOTICE
When this appliance is installed with casters, it must be installed with the casters supplied, a
connector complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device
complying with either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining
means to guard against transmission of strain to the connector, as specied in the appliance
manufacturer's instructions.
For your protection, we recommend a qualied installing agency install this appliance.
They should be familiar with gas installations and your local gas requirements. In any
case, your gas company should be called to approve the nal installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated
from the gas supply piping system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2
PSIG.
EXHAUST CANOPY
Open hearth broilers inherently create a good deal of heat and smoke and should be
installed under an efcient exhaust hood with ame proof lters. A vertical distance of not
less than 48" shall be provided between the top of the appliance and lters or any other
combustible material. Exhaust installation must conform to local codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
CAUTION
Air for combustion enters from the bottom of the unit.
Do not obstruct this area.