These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
FOR YOU R SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROM INENT LOCATI ON
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARN IN G
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all
liability.
Lang reserves the right to change specications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations,
the specications contained in this sheet are subject to change without notice. While
Lang exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions reached as a
result of using the specications. By using the information provided, the user assumes all risks
in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase
or 3 Phase:
Purchased From:
Location:
Purchase
Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 314-678-6315
NOTICE Service on this or any other Lang appliance must be performed by
qualied personnel only. Consult your Lang Authorized Service Agent Directory.
You can call our toll free number 314-678-6315 or visit our website
WWW.LANGWORLD.COM for the service agent nearest you.
3
W
D
H
4” (101.6mm)
2.5”
Elec. Connect.
6.8”
Elec. Connect.
36”
Elec. Connect.
(160 & 172 only)
IL1547
EQUIPMENT SPECIFICATIONS
Model
124
136
148
160
172
Height x Width x DepthClearance from Weight
15.0" x 24.0" x 28.2"243 lbs.280 lbs.
381mm x 610mm x 717mm110 kg127 kg
15.0" x 36.0" x 28.2"368 lbs.410 lbs.
381mm x 914mm x 717mm167 kg186 kg
15.0" x 48.0" x 28.2"
381mm x 1219mm x 717mm
Sides: 2"
Back: 2"
483 lbs.515 lbs.
220 kg234 kg
15.0" x 60.0" x 28.2"621 lbs.665 lbs.
381mm x 1524mm x 717mm282 kg302 kg
15.0" x 72.0" x 28.2"724 lbs.800 lbs.
381mm x 1830mm x 717mm329 kg364 kg
Freight
Class(Not including legs)combustible surfaceActualShipping
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the
actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer
installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
Controls
Each twelve-inch section has its own temperature dial that snaps into place to lock in any temperature
from 175°F to 450°F (79°C to 232°C) in 25° increments.
Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense
and react to a temperature change of +/- 4°F.
Each twelve-inch section has a set of 6 K.W. elements for high efciency, quick recovery and outstanding
performance
Technical
The 100 series thermostat griddle operates on either 208, 220, 240, 380, 440 or 480V, are shipped three
phase, (unless in specic specications). 208, 220, 240V can be eld converted to single phase.
Minimum clearances: 2” from side and back
NOTICE The data plate is on the right side of the griddle. The griddle voltage,
wattage, serial number, wire size, and clearance specications are on
the data plate. This information should be carefully read and understood
before proceeding with the installation.
6
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery
and signed by the carrier’s agent. Concealed loss or damage means it
does not become apparent until the merchandise has been unpacked. If
concealed loss or damage is discovered upon unpacking, make a written
request for inspection by the carrier’s agent within 15 days of delivery. All
packing
material should be kept for inspection. Do not return damaged merchan-
dise to Star Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the griddle as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the
straps and remove the wood frame.
The griddle can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN
HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT
(SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE
SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
CAUTION
WARNING
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH GRIDDLE WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
7
INSTALLATION
IL1554
Std Leg
Marine Bolt Down Leg
2.5”
IL1550
Above: typical leg installation.
Leg Installation
There are four, 4” legs provided for 2, 3 and
4 foot griddles.
There are eight 4” legs provided for 5 and 6
foot griddles.
The legs are shipped in the grease drawers
of the griddle. Install them into the threaded
holes on the underside of the griddle body.
Leveling adjustment may be done by
screwing the bottom portion of the leg in and out.
For bolt down legs see above illustration for dimensions.
:THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL
PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
WARNING
ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION
CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
WARNING
UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE
CODES.
NOTICE: The data plate is located on the right side of the griddle. The grill voltage,
wattage, serial number, wire size, and clearance specications are on
the data plate. This information should be carefully read and understood
before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood, grease extractors,
re extinguisher systems, must conform to their applicable National, State
and locally recognized installation standards.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
CAUTION
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR
FALLS.
WARNING
8