Lang 124T, 124TR, 124THE, 124TSS, 136T Operation Manual

...
IL1552
THERMOSTATIC
ELECTRIC GRIDDLE
Commercial & Marine
124T, 124TR, 124TC, 124THE, 124TSS
136T, 136TC, 136TNTS, 136THE
160T, 160TC, 160THE, 160TSS
172T, 172TC, 172TSS
Installation and
Operation
Instructions
2M-W352 Rev. G 1/25/2012
136T
1
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
FOR YOU R SAFTEY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROM INENT LOCATI ON
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT.
WARN IN G
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE. REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability.
Lang reserves the right to change specications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations,
the specications contained in this sheet are subject to change without notice. While Lang exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions reached as a
result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
SAFETY SYMBOL
Model No.:
Serial No.:
Voltage:
1-Phase
or 3 Phase:
Purchased From:
Location:
Purchase
Date:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 314-678-6315
TABLE OF CONTENTS
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5
Equipment Description
Unpacking
Installation
Leg Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ventilation & Clearence . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . 9
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Initial Start-Up
Pre-Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Seasoning Cooking Surface . . . . . . . . . . . . . . . . . . . . 10
Operation
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Loading the Griddle . . . . . . . . . . . . . . . . . . . . . . . . 11
Suggested Times and Temperatures . . . . . . . . . . . . . . . 11
Maintenance
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Crome Surface Griddle Care . . . . . . . . . . . . . . . . . . . 13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting
Symptoms / Possible Causes . . . . . . . . . . . . . . . . . . . 14
Possible Causes / Test . . . . . . . . . . . . . . . . . . . . . . 14
Wiring Diagram
208/240VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
480VAC 3 PHASE . . . . . . . . . . . . . . . . . . . . . . . . . 16
2’ Accu-Temp Electric Grid w/CSE12 Hoods . . . . . . . . . . . 17
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . 18-23
NOTICE Service on this or any other Lang appliance must be performed by qualied personnel only. Consult your Lang Authorized Service Agent Directory. You can call our toll free number 314-678-6315 or visit our website WWW.LANGWORLD.COM for the service agent nearest you.
3
W
D
H
4” (101.6mm)
2.5” Elec. Connect.
6.8”
Elec. Connect.
36”
Elec. Connect.
(160 & 172 only)
IL1547
EQUIPMENT SPECIFICATIONS
Model
124
136
148
160
172
Height x Width x Depth Clearance from Weight
15.0" x 24.0" x 28.2" 243 lbs. 280 lbs.
381mm x 610mm x 717mm 110 kg 127 kg
15.0" x 36.0" x 28.2" 368 lbs. 410 lbs.
381mm x 914mm x 717mm 167 kg 186 kg
15.0" x 48.0" x 28.2"
381mm x 1219mm x 717mm
Sides: 2"
Back: 2"
483 lbs. 515 lbs.
220 kg 234 kg
15.0" x 60.0" x 28.2" 621 lbs. 665 lbs.
381mm x 1524mm x 717mm 282 kg 302 kg
15.0" x 72.0" x 28.2" 724 lbs. 800 lbs.
381mm x 1830mm x 717mm 329 kg 364 kg
Freight
Class(Not including legs) combustible surface Actual Shipping
85
ELECTRICAL SPECIFICATIONS - MARINE
Amp 3 Ph
Supply Wire 3
PHL1 L2 L3 L1 L2 L3
Current Model Volts AC Hz. Ph.
Kw
TOT.
Amp 1PH.
Supply
Wire 1 PH
Amp 3 Ph
Supply
Wire 3 PH
Kw
TOT.
Amp 1PH.
Supply
Wire 1 PH
124T-440VM 440V 50/60 3 12 23.6 13.6 13.6 10
124T-480VM 480V 60 3 12 22 13 13 12
124T-M 208/240V 60 1/3 12 58 4 50 29 29 6
136T-440VM 440V 60 3 18 23.6 23.6 23.6 12
136T-480VM 480V 60 3 18 22 22 22 12
136THE-480VM 480V 50/60 3 18 21.7 21.7 21.7 10
124T-380VM 380V 50/60 3 12 27.3 15.7 15.7 10
136T-M 208/240V 60 1/3 18 87 2 50 50 50 6
148T-440VM 440V 60 3 24 35.4 35.4 21.7 8
148T-480VM 480V 60 3 24 33 33 22 8
148T-M 208/240V 60 1/3
24 116 1 75 75 50 3
160T-M 208/240V 60 1/3 12 58 2 50 29 29 6 18 87 2 50 50 50 6
160T-440VM 440V 60 3 12 23.6 13.6 13.6 10 18 23.6 23.6 23.6 10
172T-440VM 440V 60 3 18 23.6 23.6 23.6 12 18 23.6 23.6 23.6 12
172T-480VM 480V 60 3 18 22 22 22 12 18 22 22 22 12
172T-M 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6
4
EQUIPMENT SPECIFICATIONS
Current Model Volts AC Hz. PH
Kw
TOT.
Amp
1PH.
Supply
Wire
1 PH
Amp 3 Ph
L1 L2 L3 L1 L2 L3
Supply Wire 3
PH
Kw
TOT.
Amp 1PH.
Supply
Wire 1 PH
Amp 3 Ph
Supply
Wire 3 PH
124T 208/240V 60 1/3 12 58 4 50 29 29 6 124T-220V 220V 50/60 1/3 10 45.5 6 39.4 22.7 22.7 8 124T-220VCW 220V 50/60 1/3 10 45.5 6 39.4 22.7 22.7 8 124T-380V 380V 60 3 12 27.3 15.7 15.7 10 124T-480V 480V 60 3 12 22 13 13 12 124T-480VSJ 480V 60 3 12 22 13 13 12 124T-BK 208/240V 60 1/3 12 58 4 50 29 29 6 124TC 208/240V 60 1/3 12 58 4 50 29 29 6 124TCHE 208/240 60 1/3 12 58 4 50 29 29 6 124TC-TE 208/240V 60 1/3 12 58
4 50 29 29 6 124THE 208/240V 60 1/3 12 58 4 50 29 29 6 124THE2L 208/240V 60 1/3 12 58 4 50 29 29 6 124T-PE 208/240V 60 1/3 12 58 4 50 29 29 6 124T-PE-480V 480V 60 3 12 22 13 13 12 124TR 208/240 60 1/3 12 58 4 50 29 29 6 124TSS 208/240V 60 1/3 12 58 4 50 29 29 6 124TSS-480V 480V 60 3 12 22 13 13 12 136T 208/240V 60 1/3 18 87 2 50 50 50 6 136T-380V 380V 60 3 18 27.3 27.3 27.3 10 136T-480V 480V 60 3 18 22 22 22 12 136TC 208/240 60 3 18 87 2 50 50 50 6 136TC-TE 208/240 60 1/3 18 87 2 50 50 50 6 136TC-TE-380 380V 50 3 18
27 27 27 10 136THE-240V 208/240V 60 1/3 18 87/75 2 50/43 50/43 50/43 6 136TNTS 208/240V 60 1/3 18 87 2 50 50 50 6 136T-PE 208/240 60 1/3 18 87 2 50 50 50 6 148T 208/240V 60 1/3 24 116 1 75 75 50 3 148T-PE-480V 480V 60 3 24 33 33 22 8
148T-480V 480V 60 3 24 33 33 22 8 148TC 208/240V 60 1/3 24 116 1 75 75 50 3
148TC-TE 208/240V 60 1/3 24 116 1 75 75 50 3 148TC-TE-380 380V 50 3 24 41 41 27 6 148TC-TE-480 480V 60 3 24 31 33 22 8 148THE-208V 208/240 60 1/3 24 116 1 75 75 50 3 148T-PE 208/240V 60 1/3 24 116 1 75 75 50 3 148T-SJ 208/240V 60 1/3 24 116
1 75 75 50 3 148TSS 208/240V 60 1/3 24 116 1 75 75 50 3 148TSS-480V 480V 60 3 24 33 33 22 8 160T 208/240V 60 1/3 12 58 2 50 29 29 6 18 87 2 50 50 50 6 160T-480V 480V 60 3 12 22 13 13 12 18 22 22 22 12 160T-480VCP 480V 60 3 12 22 13 13 12 18 22 22 22 12 160TC-TE 208/240V 60 1/3 12 58 4 50 29 29 6 18 87 2 50 50 50 6 160TC-TE-480 480V 60 3 24 33 33 22 8 160THE 208/240 60 1/3 12 58 4 50 29 29 6 18 87 2 50 50 50 6 160TSS 208/240V 60 1/3 12 58 2 50 29 29 6 18 87 6 50 50 50 6 160TSS-480V 480V 60 3 12 22 13 13 12 22 22 22 12 172T 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6 172T-480V 480V 60 3 18 22 22 22 12 18 22 22 22 12 172T-480V-CP 480V 60 3 18 22 22 22 12 18 22 22 22 12 172T-480VSJ 480V 60 3 18 22 22 22 12 18 22 22 22 12
172TC 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6
172TC-480V 480V 60 3 18 22 22 22 12 18 22 22 22 12
172TC-TE 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6 172T-PE 208/240V 60 1/3 18 87 2 50 50 50 6
18 87 2 50 50 50 6 172T-PE-480V 480V 60 3 18 22 22 22 12 18 22 22 22 12 172T-SJ 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6
172TSS 208/240V 60 1/3 18 87 2 50 50 50 6 18 87 2 50 50 50 6
5
EQUIPMENT DESCRIPTION
Griddle Surface
Gutter
Grease Pan
Feet
Section
Temp. Dial
Section
Pilot Light
IL1553
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery problems, warping, and ensure even heat to the edges of the griddle.
Controls
Each twelve-inch section has its own temperature dial that snaps into place to lock in any temperature from 175°F to 450°F (79°C to 232°C) in 25° increments.
Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense and react to a temperature change of +/- 4°F.
Each twelve-inch section has a set of 6 K.W. elements for high efciency, quick recovery and outstanding
performance
Technical
The 100 series thermostat griddle operates on either 208, 220, 240, 380, 440 or 480V, are shipped three
phase, (unless in specic specications). 208, 220, 240V can be eld converted to single phase.
Minimum clearances: 2” from side and back
NOTICE The data plate is on the right side of the griddle. The griddle voltage,
wattage, serial number, wire size, and clearance specications are on
the data plate. This information should be carefully read and understood before proceeding with the installation.
6
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier’s agent. Concealed loss or damage means it does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered upon unpacking, make a written request for inspection by the carrier’s agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchan-
dise to Star Manufacturing Company. File your claim with the carrier.
Location
Prior to un-crating, move the griddle as near to its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the straps and remove the wood frame.
The griddle can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
CAUTION
WARNING
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH GRIDDLE WILL BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
7
INSTALLATION
IL1554
Std Leg
Marine Bolt Down Leg
2.5”
IL1550
Above: typical leg installation.
Leg Installation
There are four, 4” legs provided for 2, 3 and 4 foot griddles.
There are eight 4” legs provided for 5 and 6 foot griddles.
The legs are shipped in the grease drawers of the griddle. Install them into the threaded holes on the underside of the griddle body.
Leveling adjustment may be done by screwing the bottom portion of the leg in and out.
For bolt down legs see above illustration for dimensions.
: THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL
PROVIDED. FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
WARNING
ELECTROCUTION AND DEATH.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
WARNING
UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE: The data plate is located on the right side of the griddle. The grill voltage,
wattage, serial number, wire size, and clearance specications are on
the data plate. This information should be carefully read and understood before proceeding with the installation.
NOTICE: The installation of any components such as a vent hood, grease extractors,
re extinguisher systems, must conform to their applicable National, State and locally recognized installation standards.
ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.
CAUTION
KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY. IF SPILLS
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR FALLS.
WARNING
8
Loading...
+ 16 hidden pages