LANCOM WLC-30
4
Quick Reference Guide
TP Ethernet interface (Uplink)
a
Connect the Uplink interface to a LAN switch or a WAN modem with a suitable cable.
TP Ethernet interfaces
b
Use one of the enclosed cables with the kiwi-colored connectors to connect the interface ETH 1 to ETH 4 to your PC or a LAN switch.
Serial configuration interface
c
For configuration, connect the device and a PC with a configuration cable (cable sold separately).
USB interface
d
You can use the USB interface to connect a USB printer or a USB flash drive for device configuration
Uplink
a
b c d
Reset button
e
Pressed up to 5 seconds: device restart
Pressed until first flashing up of all LEDs: configuration reset and device restart
Power
f
After connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place. Use only the supplied power adapter.
Reset
e
f
AP Status
Uplink
a db fec
a Power
Off Device switched off
Green, permanently* Device operational,
Green/orange, blinking Configuration password not set. Without a
Red, blinking Charge or time limit reached
1x green inverse blinking*
2x green inverse blinking*
3x green inverse blinking*
b AP Status
Green, permanently At least one active access point is con-
Green/orange, blinking At least one new access point.
Red, permanently The LANCOM Wi-Fi controller is not yet
Red, blinking At least one of the expected access points
resp. device paired / claimed and LANCOM Management Cloud (LMC) accessible
configuration password, the configuration data in the device is unprotected.
Connection to the LMC active, pairing OK, device not claimed
Pairing error, resp. LMC activation code not available
LMC not accessible, resp. communication error
nected and authenticated; no new and no missing access point.
operational; one of the following elements is missing:
a Root certificate a Device certificate a Current time a Random number for the DTLS encryption
is missing.
LANCOM WLC-30
ETH 1
ETH 2
ETH 3
ETH 4
Online
VPN
c Uplink
Off No networking device attached
Green, permanently Connection to network device operational,
Green, flickering Data transmission
no data traffic
d ETH
Off No networking device attached
Green, permanently Connection to network device operational,
Green, flickering Data transmission
no data traffic
e Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
f VPN
Off No VPN connection active
Green, permanently VPN connection active
Green, blinking Establishing VPN connections
Hardware
Power supply 12 V DC, external power adapter (110 or 230 V) with bayonet connector to secure against
disconnection
Power consumption Max. 8.5 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; mea-
sures 210 x 45 x 140 mm (W x H x D)
Interfaces
Uplink 10 / 100 / 1000 Mbps Gigabit Ethernet
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet.
Each Ethernet port can be freely configured (LAN, WAN, monitor port, off). LAN ports operate in switch mode or isolated. Additionally, external DSL modems or termination routers can be operated at the Uplink port together with policy-based routing.
USB USB 2.0 Hi-Speed host port for connecting USB printers (USB print server) or USB data media
(FAT file system)
Config (Com) Serial configuration interface / COM port (8-pin Mini-DIN): 9,600 - 115,000 baud, suitable for
optional connection of analog / GPRS modems. Supports the internal COM-port server.
WAN protocols
Ethernet PPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP),
RIP-1, RIP-2, VLAN, IP, GRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and IPv4/IPv6 Dual Stack Session), IP(v6)oE (autoconfiguration, DHCPv6 or static)
Declaration of conformity
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN) Cable Ethernet cable, 3m (kiwi-colored connectors) WLC Public Spot Function included in firmware Power adapter External power adapter, 12 V / 2 A DC, barrel connector 2.1 / 5.5 mm bayonet,
LANCOM item no. 111303 (not for WW devices)
LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This docu-
ment contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions. 111974/0421
Cloud-ready
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible. A For devices to be operated on the desktop, please attach the adhesive rubber
footpads.
Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide! Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.
A Do not rest any objects on top of the device and do not stack multiple devices. A Keep the ventilation slots on the side of the device clear of obstruction.
*) The additional power LED statuses are displayed in 5-seconds
MOUNTING AND CONNECTING THE DEVICE
rotation if the device is configured to be managed by the LANCOM Management Cloud.
TECHNICAL DATA
Loading...