Subject: CEV/CED Agitator Motor Assembly Kit
Kit Contents
Part Number Description Quantity
5012492 * 115V Motor Assembly 1
5012704 * 208/230V 60Hz Motor Assembly 1
5012789 * 220/240V 50Hz Motor Assembly 1
5008844 1/4” Female Spade Connector 2
5028314 Instructions 1
* Kit will contain one of the listed motor assemblies
CEV INSTALLATION
CED INSTALLATION
Instructions
5028314
10/09
1. Turn of f the power to the CEV and unplug the unit
from its power source.
2. Unplug the defective agitator motor from the co ntro l
box.
3. Remove the defective agitator motor from the
refrigeration deck.
4. Install the new agitator motor on the refrigeration
deck.
5. Plug the new agitator motor into the control box.
6. Plug the unit back into the power source and turn on
the power switch.
Manitowoc Foodservice Group, 2110 S. 26th St., P.O. Box 1720, Manitowoc, WI 54221-1720, Tel: 920-682-0161, www.manitowocfsg.co m
1. Disconnect the power cord from the side of the
control box.
2. Remove the front cover of the control box.
3. Disconnect the defective agitator motor power supply
from the terminal board and the agitator switch.
4. Remove the defective agitator motor from the
refrigeration deck.
5. Cut the Lumberg plug off the end of the new agitator
motor.
6. Install the new motor on the refrigeration de ck and route
the wires into the control box.
7. Crimp the two 1/4” female spade fittings into each wire
on the new motor.
8. Plug one wire onto the agitator switch and the other to
the neutral side of the terminal board.
9. Connect the power cord to the plug on the side of the
control box.