Lambda LOT-W-5152-A, LOT-X-5152-A Service Manual

INSTRUCTION MANUAL
REGULATED POWER SUPPLIES
LOT—W-5152-A, LOT—X-5152-A
SPECIFICATIONS AND FEATURES
DC OUTPUT — Voltage regulated for line and load. For voltage and current ratings see table I below.
TABLE I
MAXIMUM CURRENT (AMPS)
LOT-W-5152-A
LOT-X-5152-A
Current range must be chosen to suit the appropriate maximum ambient temperature. Current ratings apply for entire voltage range. REGULATED VOLTAGE OUTPUT (each output)
Regulation (line) 0.15% for input variations from 105-125, 125-105, 210-250, or Regulation (load) 0.15% for load variations from no load to full load or full load to no Ripple and Noise 1.5mV rms, 5mV peak to peak.
Temperature Coefficient 0.03%/°C Remote Programming (5V output only)
Extemal Resistor Nominal 200 ohms/volt output. Use a low temperature coefficient Programming Voltage One-to-one voltage change. The programming supply must have a
Remote Sensing Provision is made for remote sensing to minimize the effect of
VOLTAGE
RANGE
5±5%
±12 to±15
5 ±5%
±12 to ±15
AT AMBIENT TEMPERATURE
40° C
6.0
1.0
3.0
0.500
250-210 volts AC.
load.
resistor to assure most stable operation. reverse current capability of 6 ma. min. power output lead resistance on DC regulation. Sensing leads
should be a twisted pair to minimize AC pickup. A 2.5 mf, elect., capacitor may be required between output terminals and sense terminals to reduce noise pickup.
50°C
4.5
0.750
2.2
0.375
60° C
3.0
0.400
1.4
0.200
1
OVERSHOOT — No overshoot under conditions of power tum-on, AC INPUT —105-125 or 210-250 volts AC at 47-440 Hz. Standard LOT-W and LOT-X power supplies are factory wired for 105-125
volt input, but are available factory wired for 210-250 volt input. See Figure 1 and schematic diagram for rewiring of AC input. Input power*: 175 Watts (LOT-W) 90 watts (LOT-X). Power factor*: 0.8. Ratings apply for 57-63 Hz input. For 47-53 Hz input derate current 10% for each ambient temperature given in table I. For 63-440 Hz input consult factory.
•With output loaded to full current rating and input voltage 125 volts AC, 60 Hz.
TRACKING (±12 to ±15V output only) — Absolute difference between negative and positive outputs within 2%; 0.2% change for all
conditions of line, load, and temperature.
OVERLOAD PROTECTION — Automatic electronic current limiting circuit, limits output current to a safe value, protecting load and
power supply when overloads and direct shorts occur.
INPUT AND OUTPUT CONNECTIONS - See outline drawing for location.
AC input Terminals on transformer Ground Terminal on transformer DC output Turret terminal on printed circuit board Sensing Turret terminal on printed circuit board Overvoltage Protector Quick disconnect terminal on printed circuit board with mating con-
OPERATING AMBIENT TEMPERATURE RANGE AND DUTY CYCLE
corresponding load current ratings for all modes of operation. STORAGE TEMPERATURE - -20°C to +85°C DC OUTPUT CONTROL — Screwdriver voltage adjust controls permit adjustment of DC output voltages. One control simultane-
ously adjusts the dual (±12 to ±15V) outputs. A separate control is provided for the single, 5V output. See outline drawing
for location of controls. GUARANTEE — 60 day guarantee from date of shipment PHYSICAL DATA
Size LOT-W: 9" x 4-7/8" x 2-3/4"; LOT-X: 7" x 4-7/8" x 2-3/4"
Weight LOT-W: 7-3/4 lbs. net, 8-1/4 lbs. shipping; LOT-X: 5-1/2 lbs. net,
Finish Gray, FED. STD. 596 No. 26081
turn-off,
nector attached.
. . materials and labor.
6 lbs. shipping.
or power failure.
Continuous duty from 0°C to +60 C ambient with
MOUNTING — Three surfaces, each with clearance mounting holes, can be utilized for mounting this unit. Air circulation is
required when unit is mounted in confined areas. Refer to Outline Drawing for mounting details.
"J"
OPTION - Standard LOT-W and LOT-X power supplies can be obtained for 90-110 VAC, 47-440 Hz input. For 47-53 Hz
input derate current 10% for each ambient temperature given in table I. For 63-440 Hz input consult factory.
ACCESSORIES
Overvoltage protector L-12-0V series Overvoltage Protectors are available.
ACI D AC2
LkUMJ
BLK WHT
1 1
j|tAC
INPUT CONNECTION SHOWN IS FOR I0S-I25VAC FOR 2IO-250V INPUT, DISCONNECT BLK a WHT TRANFORMER LEADS FROM TERMS ACI B AC2 ANO RECONNECT BOTH LEADS TO TERM 0
AC INPUT
±
o
Figure 1. AC Input Connection.
OPTIONAL
OVERVOLTAGE
PROTECTOR
-OV +0V
-V COM -fV
HVs/v-*-vv\ni
LOA 0(8)
(A) LOCAL SENSING CONFIGURATION. (B) REMOTE SENSINS
OPTIONAL
OVERVOLTAGE
PROTECTOR
-OV -wv
-S -V +7 -fS
•WV/* LOAD
* LOAD(S) CAN BE CONNECTED IN ANY LOAO(S)
W » A 2.SMF,ELECT.,CAP. MAY BE REQUIRED.
INPUT
Figure 2. AC Input Connection, "J" Option.
OPTIONAL
OVERVOLTAGE
PROTECTOR
-OV +0V
-V COM -fV
OPTIONAL
OVERVOLTAGE
PROTECTOR
^
-OV +0V
-S -V *v +s
99
W
««
W
««
LOAD
Figure 3. DC Output Connection.
-S -V tV •$
-S -V W +8
^9?
PROG VTCE.
200/\/
VOLT
•wv*
LOAD
PROO.
VTOE.
200 A /VOLT
"Vwii
LOAD[
i
Tit-
t.SMF
toov
(A) LOCAL SENSING (B) REMOTE SENSING
» A 2.SMF, ELECT.,CAP. MAY
BE
REQUIRED.
Figure 4. Programmed Voltage, With External Resistor (5V Output Only).
Z.SMF
200V