laguna Powerjet 250, Powerjet 500, Powerjet 1000, Powerjet 1500 Installation And Maintenance Manual

Installation and Maintenance Guide
READ THOROUGHLY BEFORE ATTEMPTING INSTALLATION AND KEEP FOR FUTURE REFERENCE
Einbau- und Wartungsanleitung
SORGFÄLTIG VOR BEGINN DER INSTALLATION DURCHLESEN UND FÜR SPÄTERE VERWENDUNG AUFBEWAHREN
À LIRE SIOGNEUSEMENT AVANT D’ENTENPRENDRE L’INSTALLATION DE L’APPAREIL. CONSERVER CETTE NOTICE POUR RÉFÉRENCES ULTÉRIEURES
Guida all’ installazione e Manutenzione
LEGGERE ATTENTAMENTE E CONSERVARE QUESTE ISTRUZIONI PER OGNI FUTURO RIFERIMENTO
Instalación y Guía de Mantenimiento
LEER ESTE FOLLETO MINUCIOSAMENTE ANTES DE INTENTAR LA INSTALACIÓN Y GUARDAR ESTAS INSTRUCCIONES PARA REFERENCIAS EN UN FUTURO
250 500 1000 1500
Examples of different installations Bespiele für verscheidene Anlagen Exemples d’installations Ejemplo de direntes instalaciones Esempi di diverse installazioni
Laguna Powerflo Underwater Filter
Laguna Powerflo Unterwasser-Filter
Filtre Submersible Laguna Powerflo
Filtro Sumergible Laguna Powerflo
Filtro Interno Laguna Powerflo
FOUNTAIN AND ORNAMENT (500, 1000, & 1500)
SPRINGBRUNNEN UND ORNAMENT (NUR 500, 1000 UND 1500)
FONTAINE ET ORNEMENT (500, 1000 ET 1500 SEULEMENT)
FUENTE Y ADORNOS (500, 1000 Y 1500 SOLAMENTE)
DECORAZIONE PER FONTANA (SOLO POWERJET 500, 1000 E 1500)
FOUNTAIN AND WATERFALL (500, 1000, & 1500)
SPRINGBRUNNEN UND WASSERFALL (NUR 500, 1000 UND 1500)
FONTAINE ET CASCADE (500, 1000 ET 1500 SEULEMENT)
FUENTE Y CASCADAS (500, 1000 Y 1500 SOLAMENTE)
FONTANA E CASCADA (SOLO POWERJET 500, 1000 E 1500)
ORNAMENT
(ALL MODELS)
SPRINGBRUNNEN UND
ORNAMENT
(ALLE MODELLE)
ORNEMENT
(TOUS LES MODÉLES)
ADORNOS
(TODOS LOS MODELOS)
DECORAZIONE
(TUTTI I MODELLI)
FOUNTAIN ONLY
(ALL MODELS)
NUR SPRINGBRUNNEN
(ALLE MODELLE)
FONTAINE SEULEMENT
(TOUS LES MODÉLES)
FUENTE
(TODOS LOS MODELOS)
FONTANA
(TUTTI I MODELLI)
PART NUMBERS / TEIL-NUMMER / NUMÉRO DES PIÉCES / NÚMERO DE PIEZAS / CONDICI RICAMBI
250 500 1000 1500
1 PT710 PT712 PT714 PT715 2 PT756 PT758 PT759 PT759 3 PT450 PT452 PT454 PT455 4 PT732 PT734 PT736 PT737 5 PT470 PT472 PT474 PT474 6 PT744 PT746 PT748 PT748 7 PT724 PT726 PT728 PT728 8 PT600 PT605 PT605 PT605 9 PT610 PT610 PT615 PT615 10 PT660 PT660 PT662 PT662 11 PT650 PT650 PT652 PT652 12 PT603 PT603 PT603
250 500 1000 1500
1
8
3
4
5
9
11
10
7
2
6
1
12
To remove Ceramic Shaft unit, use provided tool.
Zum Entfernen der Keramikachsen-Einheit beigef gtes Werkzeug benutzen.
Pour enlever le bloc de l arbre de c ramique, utiliser l outil fourni.
Para desmontar el conjunto de v stago de cer mica, colocar un peque o destornillador de cabeza plana debajo de uno de los rebor­des amarillos, y levantarlo suavemente.
Usare l apposito attrezzo per rimuovere l al­bero ceramico.
WARNING: SAFETY & ELECTRICAL CONNECTIONS
IMPORTANT SAFEGUARDS
1.
DANGER
- To avoid possible electric shock, special care should be taken since water is employed in the use of pond equipment. To guard against injury, basic safety precautions should be observed.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
on the use and maintenance of this appliance. Disregarding this advice may result in damage to the pump or personal injury.
2. For each of the following situations, do not attempt repairs yourself; return the pump to an authorised service facility for service or discard the pump.
A. If the pump falls in the water DON’T reach for it! Unplug it from the
electrical supply BEFORE retreiving it. Carefully examine the integrity of the pump; if the motor body is cracked or damaged, DISCARD. If electrical components in the pump get wet unplug it immediately.
B. Do not operate any pump which malfunctions, has a damaged cord or
plug, or if it has been dropped or damaged in any way. The power cord of this pump cannot be replaced; if the cord is damaged discard the pump. Never cut the cord.
C. If the appliance shows any sign of current leakage or if RCD (GFCI -
Ground Fault Current Interruptor) switches off, disconnect the power supply cord from mains and remove pump from water.
3. Children must be closely supervised at all times near water.
4.
IMPORTANT
: Always disconnect the pump when not in use, before adding or removing parts and before cleaning. Never yank the cord and never lift the pump by the cable.
5. To avoid injury, do not touch moving parts or hot parts.
6. Do not use the pump for any other purpose than that which is intended
(ie. do not use in swimming pools, bathrooms, etc.). The use of attachments not recommended or sold by the manufacturer may cause unsafe conditions.
* Do not use this pump in swimming pools or other situations where people
are immersed.
* This pump is suitable for use in water temperatures up to 35
°
C (95
°F)
.
* Do not use this pump with inflammable or drinkable liquids.
7. Do not install or store this pump where it will be exposed to the weather, freezing conditions or when there is the possibility of below zero temperatures. Remove and store the pump in a sheltered place. Shelter pump also from direct sunlight. The materials have high stability to sunlight but direct rays may over heat the motor and speed up insulator ageing.
8.
WARNING
- Risk of electric shock! This pump is supplied with a ground­ing conductor an groundig-type attachment plug. To reduce risk of elecrtic shock, be certain that is connected only to a properly grounded, grounding type receptacle. Do not remove cord and strain relief. Do not connect conduit to the pump. To reduce risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimensions (for U.S.A. only). Check the installation and earth connections before switching on the pump.
9. It is best not to use extension cords. If an extension cord is required, ensure connection is water tight and dust proof. The cord must have three leads (Live - Neutral - Earth). Carefully check that the leads are properly connected. If in doubt consult a qualified electrician.
10. Do not allow pump to run dry. Pump must be immersed in water completely.
11. IMPORTANT: Supply through a Residual Current Device (RCD or GFCI­Ground Fault Current Interrupter) with rated residual operating current not exceeding 30mA.
12. Read and observe all the important notices in this leaflet.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Only the faithful observation of these installation, electrical and maintenance guidelines will ensure the safe and efficient use of this pump.
PUMP INSTALLATION INSTRUCTIONS
WARNING: Always unplug or disconnect all applicances in the pond from the electricity supply before putting your hands in the water whilst the equipment is being installed, repaired, maintained or handled.
The pump should be placed on a flat level surface. The pump foot can be removed and secured to a fixed base, a brick for example would provide a firm platform and may help to elevate the pump from the pond bottom. To prevent constant clogging of the pump strainer, install the pump on a elevat­ed surface so that the pump intake is clear of the pond bottom.
Important:
Always use the largest bore hose possible.
Avoid sharp bends in the hose, gentle curves are preferred.
MAINTENANCE
FOUNTAIN JETS
Remove jet head from Riser Pipe. 2-Step, 3-Step and Waterbell Jets can be dis­assembled. Rinse parts in clean water and reassemble.
PUMP STRAINER
This is not a Pond Filter. The purpose of the foam strainer is to prevent debris
from entering the impeller and will restrict pump output if clogged by pond waste and debris. To clean the strainer, simply remove the strainer housing and rinse out strainer in clean water.
If the strainer supplied with the pump is not adequate for your requirements a Laguna Powerflo Underwater filter (PT500 or PT505) should be fitted (does not apply to model 250).
Adding the Powerflo filter is simply achieved by connecting the 1
1
/4” Fast Coupling (supplied) to the pump inlet. Powerflo filters are supplied with a Universal Fast Coupling. Connect the two couplings with a length of flexible hose using the largest size hose possible.
IMPELLER
WARNING: These motor units incorporate a ceramic impeller shaft. This shaft will give reliable, long life. However this shaft is brittle. Please take extreme care when cleaning. Replacement shafts are available.
To clean the impeller and impeller housing:
1. Remove strainer housing and strainer.
2. Remove impeller cover by releasing the four screws with a crossheaded
screwdriver.
3. Remove impeller.
4. Clean all components in clean water. DO NOT USE DETERGENTS OR OTHER
CHEMICAL CLEANERS.
5. Reassemble impeller assembly and replace strainer assembly.
PUMP CARE
To avoid shortening the life of your Powerjet Pond Pump, please follow this
procedure. Maintenance is simple to carry out and essential.
Once a week - Remove and clean strainer (depending on pool conditions). Once a month - Remove and clean impeller assembly checking for build up of
limescale which can seriously affect the pump performance. Impeller well should also be checked.
To keep your Powerjet pond pump in good working order always replace any worn parts.
If you experience any difficulty, contact your local supplier or Customer Services: See back cover.
IMPORTANT
Never operate pump without strainer assembly in place. If strainer supplied is not suitable for your use, purchase Laguna Powerflo Underwater Filter (PT500 or PT505). See page 1
TROUBLE SHOOTING
LOW FLOW FROM PUMP
Check strainer is clean. Check hose for blockages.
POOR FOUNTAIN DISPLAY
Clean fountain jet.
NO FLOW FROM PUMP
Check power supply is on. Check fuse (UK market only) and wiring. Disconnect the pump, remove impeller assembly and clean, and then reconnect the pump.
2
POWERJET PUMP
250 500 1000 1500
Voltage (V) 120 230-240 120 230-240 120 230-240 120 230-240
Frequency (Hz) 60 50 60 50 60 50 60 50
Wattage (W) 6.5 3.5 11 12 19 21 32 32
Maximum depth (m) 2 2 2 2
Max flow rate (LPH/GPH) 350/92 808/214 830/219 1450/384 2220/586
Max head (cm/ft) 80/2.6 130/4.26 170/5.58 168/5.51 177/5.8 173/5.8
Degree of protection IPX8 IPX8 IPX8 IPX8
ADDITIONAL INSTRUCTIONS FOR PUMPS WITHOUT PLUG ONLY
This product is designed to be permanently wired to the mains supply in a dry weatherproof enclosure through a double pole switched fused spur which complies to BS3676, fitted with a 3 Amp fuse. The installation must conform to the regulations of the Local Electricity Authority which could include the use of plastic or metal conduit to protect the cable. A 30 mA Residual Current Device ‘RCD’ must be fitted to the mains sup­ply.
WARNING - THIS APPLIANCE MUST BE EARTHED. IMPORTANT
- The wires in this mains lead are coloured in accordance
with the following code:
BROWN - LIVE BLUE - NEUTRAL GREEN/YELLOW - EARTH
The Brown lead should be connected to the Live
terminal, which may be
marked with an ‘L’ or coloured brown or red. The Blue lead should be connected to the Neutral terminal, which may
be marked with an ‘N’ or coloured blue or black. The Green/Yellow lead should be connected to the Earth terminal, which
may be marked with an ‘E’ or coloured green or yellow.
WARRANTY
The Powerjet Pond Pumps are guaranteed against defects in material or
workmanship for a period of 3 years from date of purchase, under normal usage.
Powerjet Pond Pumps will be repaired or replaced at manufacturer’s discretion, free
of charge. This warranty does not apply to any Powerjet Pond Pump which has
been subjected to misuse, negligence, tampering or accidental damage to impeller
or impeller shaft. No liability is assumed with respect to loss or damage to livestock
or personal property irrespective of the cause thereof. This warranty does not affect
your statutory rights. Failure caused by misuse is not covered by this warranty.