Labnet 35, 35D Operating Instructions Manual

Operating Instructions
Labnet
Benchtop Rocker
Model 35/35D
T able of Contents
Introduction 1
Warranty 2
Specifications 3
Operation 4
Adjusting Platform Tilt 4
Safety Precautions 5
Care and Maintenance 6
Where to Call 6
Copyright January 2000, Labnet International Inc. All rights reserved. Reproduction without prior written permission is prohibited. Information contained herein subject to change without notice.
Introduction
The Model 35/35D Benchtop Rocker is intended for general purpose applications requiring constant rocking. The rocker can be used in environments from 4º to 65ºC. This allows f or cold room use as well as incubated applications.
The rocking platform is covered with a nonslip rubber mat to provide stability. Plates , dishes and other sample containers ma y be placed on its surface. The degree of tilt the platf orm achiev es while rocking can be adjusted to ±20º. The number of tilts per minute can be varied from 4 to 160 as required to suit particular applications. A two hour timer with hold position controls operation.
The Model 35/35D Benchtop Rocker is constructed of heavy gauge steel. This provides the rocker with a stable base for vibration free operation. The maximum load the roc king platform can carry is 4.6kg.
The Model 35/35D Benchtop Rocker is available with either a single or double platform. In the double platform version, the second plat­form attaches to the first platform by means of metal rods. The clear­ance between the two platforms is 82mm.
Read this instruction manual thoroughly before attempting to operate the Model 35/35D Benchtop Rocker . All persons operating this piece of equipment should review the Safety Precautions section of this manual.
1
Warranty
Labnet International guarantees that the Model 35/35D Benchtop Rocker you have received meets its published specification. The Model 35/35D Benchtop Rocker is guaranteed to be free of defects in materials and workmanship for a period of one year from the date of purchase. This guarantee is valid only if the unit has been used in accordance with the instructions in this manual and for its intended purpose. Labnet International shall not be responsible for consequen­tial damages or damages resulting from the abuse or misuse of this equipment. Labnet International’s liability shall be limited to the repair or replacement of the unit or refund of the purchase price, at Labnet International’s discretion.
In the event that service is required, Labnet International’s Service Department must first be contacted to receive a return authorization number.
Labnet International reserves the right to alter the specification of the Model 35/35D Benchtop Rocker without notice. This allows the in­corporation of improvements as they are developed.
Please fill in the following information. This information will be re­quired in the event that service becomes necessary .
Serial Number _________________________________ Date of Purchase _______________________________
2
Specifications
Shaking speed 4 to 160 tilts per minute Timer 1 minute to 2 hours or “hold” Operating Environment 4º to 65ºC Platform Dimensions 360 x 280mm Rocking Motion Adjustable, ±20º tilt Maximum Load 4.6kg Clearance between platforms 82mm (Double platform unit only) V oltage Requirements 120V/60Hz
Power/Current 60W/0.5amps
Unpacking and Installation
Upon receipt of the Model 35/35D Benchtop Rocker, examine the exterior carton for damages. In the event of shipping damage, a claim must be filed with the transportation carrier within 10 days.
Carefully unpack the unit and check for completeness. Included in the carton should be the following:
Rocker with platform(s) Securing hardware for second platform (35D only) Instruction Manual Warranty Card
If any of these items are missing, contact Labnet International’s Cus­tomer Service Department immediately .
Save the original packaging until the unit has been shown to be oper­ating properly .
Verify that the unit is rated for the proper voltage by checking the panel on the back. Check that the proper power cord has been re­ceived. The serial number is also found on the back panel. Make note of the serial number in the space provided in the W arr anty sec­tion of this manual.
The Model 35/35D Benchtop Rocker should be located on a level, stable surface near a grounded electrical outlet. Allow sufficient clear­ance on all sides of the unit, at least 3 inches, for proper ventilation. Ensure that the platform will not touch other objects while in opera­tion.
If the unit is supplied with an optional upper platform, it should be
3
installed at this time. Remove the hardware from the bottom threads of the platform standoffs. Note the order of the hardware on the threads. Place one large flat washer over each of the four holes on the bottom platform. Insert the threads of each of the four standoffs through the holes in the platform and the washers. Replace all hard­ware in the order in which it was removed. Do not overtighten the wingnuts.
Plug the power cord into a grounded wall soc ket. The Model 35/ 35D Benchtop Rocker is now ready for use.
Operating the Model 35/35D Benchtop Rocker
The Model 35/35D Rocker may be operated in either timed or con­tinuous mode.
To operate in timed mode, turn the speed dial to the desired setting. T urn the timer knob clockwise to the desired time. Time can be set in 1 minute increments between 1 and 120 minutes. Turning the timer activates operation of the rocker. Operation will continue until time has expired or the timer is turned back (counterclockwise) to the zero position.
T o operate in continuous mode, turn speed dial to the desired setting. Turn the timer knob left (counterclockwise) to the hold position. This will begin operation of the rocker. Operation will continue until the timer knob is turned back (clockwise) to toe zero position.
Note: The timer ma y be stiff and offer some resistance when turned. This is normal.
Operation of the rocker may also be stopped at any time by turning the speed dial to the zero position. When the speed dial is turned to the zero position, the timer will continue to count down.
Note: To avoid splashing of samples, the rocker should be started with the speed dial at the lowest position and gradually turned up to the desired speed.
Adjusting Platform Tilt
The tilt of the platform can be adjusted to ±20º. The tilt is factory preset at ±10º. Instructions for adjusting the tilt are as follows.
1. Unplug the unit from the wall outlet.
4
2. Locate the access panel on the back of the unit and remove the 2 screws holding the panel in place.
3. Position a 7/16 inch wrench or adjustable wrench on the nut holding the bottom connecting rod to the disk. Use the wrench to turn the disk until the locking hole in the motor shaft collar is aligned with the access hole on the rear panel. The locking hole is located 180º from the collar’s set scre w .
4. Insert the locking rod through the access hole and into the locking hole of the motor shaft collar. This will prevent the disk from turning while loosening or tightening the nut holding the bottom connecting rod in place.
5. Loosen the 7/16 inch nut just enough to allow movement of the nut and connecting rod in the slot. Move the nut outward from the center of the disk to increase tilt action. Move the nut inward toward the center of the disk to decrease tilt action.
6. When correct action is obtained, retighten the nut.
7. Remove the locking rod.
8. Replace access cover
Safety Precautions
The following precautions should be taken when operating or work­ing near the Model 35/35D Benchtop Rocker:
Never operate the rocker without a platform securely attached.
Always wear shatterproof eye protection. Always make certain that the platform and any hardware are
secure before operating the shak er. Load the rocker symmetrically. Unbalanced loads should
be avoided. Solvents and flammables should not be used on or near the
shaker . Service and repair must only be performed by qualified
professionals. Hazardous samples should be shaken only in appropriate
containment vessels.
5
Care and Maintenance
After each use, the Model 35/35D Benchtop Rocker should be wiped down with a soft, damp cloth. Do not immerse the rocker in water or pour liquids over the unit as electrical shock may occur.
The rod bearing should be lubricated every 3 to 6 months with a few drops of oil (Three-in-One, Handy Oil or similar). The motor and plat­form bearings are permanently lubricated and need no maintenance. If the rocker us used at temperatures above 37ºC, the rod ends must be oiled every month to maintain proper operating condition. Never use the Model 35/35D Benchtop Rocker in environments above 65ºC
Where to Call
If you have a question about the Model 35/35D Benchtop Rocker,
contact Labnet International’s Customer Service Department at 732 417-0700, Monday through F riday, 8:30am to 5:30pm, EST .
For service inquiries, contact Labnet International’s Service Depart­ment at 732 417-0700, Monday through Friday, 9:00am to 5:00pm, EST . Bef ore returning a unit for service, a Return Authorization (RA) number must first be obtained from the service department. Equip­ment sent in without prior authorization will be returned at the customer’s expense.
If the unit must be returned to Labnet International for servicing, it should be sent in the original packaging. If this is not possible, be sure that the unit is sufficiently packed. An y damage resulting from improper packaging is the responsibility of the customer . A written explanation should accompany the unit along with the return autho­rization number.
6
Notes
Loading...