LAB.GRUPPEN C 5:4X Technical data

C 5:4X
Technical Data
C Series: Dedicated Installation Amplifiers
▸ High channel density reduces space requirements and installa-
tion time
High continuous output power of 125 W per channel
at 70 V, 4 ohms, 8 ohms, and 16 ohms*
All channels individually selectable for lo-Z or hi-Z
Loudspeakers (2 ohm – 16 ohm) and distributed systems can be connected to the same unit
Bridged operation – Channel pairs bridgeable for increased
output or for driving 100 V systems
Patented output stage based on Class D topology
High efficiency for lower thermal stress
An Installation Amplifier without Compromise
Lab.gruppen amplifiers have earned an enviable worldwide reputa­tion for sonic excellence and rock-solid durability in touring sound ap­plications. These same qualities are now available for a broad range of installed sound applications in the C 5:4X amplifier. By offering an unmatched combination of channel density, operating efficiency and configuration flexibility, the C 5:4X presents convincing performance and cost-saving advantages. Applications include primary systems for theme parks, shopping malls, airports, hotels and restaurants as well as auxiliary systems for performance venues, houses of worship and numerous other installed sound applications.
To achieve higher channel density without compromising per­formance, Lab.gruppen engineers developed a new output stage design. Based on a patented Class D circuit topology, these output stages produce sustained high power levels with very low distortion while maintaining efficiency levels of near 90%. A new universal switching power supply employs Power Factor Correction (PFC) to stabilize current draw, and it accepts any mains voltage from 65 – 265 V (+/- 10%) @ 50 Hz or 60 Hz through the appropriate IEC cord.
The C 5:4X includes include unique features which enable each unit – or even each channel – to be configured for a specific application or load condition. Input gain is selectable in two -channel groups, and a 35 Hz high pass filter may be inserted. All channels are bridgeable in pairs, and Lab.gruppen’s exclusive Voltage Peak Limiter (VPL) fea­ture allows each channel to be individually optimized for the reactive characteristics of the connected load.
General Purpose Input/Output (GPIO) – Compatible with
third-party control systems
NomadLink
Universal Power Factor Corrected PSU with IEC inlet
Efficient cooling – Dual variable speed, intelligent fans and
parallel airflow over output devices provide uniform cooling
Comprehensive circuit protection and fault indication
Phoenix-style input connectors and barrier strip output
connectors
For comprehensive remote monitoring and control, the C 5:4X includes NomadLink network ports for connecting to an optional NLB 60E NomadLink Bridge & Network Controller and an Ethernet­linked PC. With NomadLink, key amplifier parameters are displayed via DeviceControl software, and remote control of channel mute and power on/off is under network control. Alternatively, the GPIO facilities allow access to key amplifier functions via third-party remote control systems.
To ensure a long and trouble-free service life, the C 5:4X incorpo­rates extensive features to safeguard internal circuits and connected loads. Protection and warning circuits prevent damage or service in­terruptions due to excessive current, DC at output, over-temperature, non-musical VHF (very high frequencies), and open load conditions. In addition, soft-start and PSU current limiting protect the mains supply from interruptions due to tripped circuit breakers or blown mains fuses.
®
network ready
Applications
▸ Auditoriums ▸ Performing Arts Centers ▸ Convention Centers ▸ Stadiums and Arenas ▸ Theme Parks ▸ Hotels ▸ Houses of Worship
▸ Restaurants ▸ Clubs ▸ Educational Establishments ▸ Boardrooms ▸ Museums ▸ Offices ▸ Shopping Malls ▸ Transportation Facilities
* Maximum continu ous output power, all chann els
driven, VP L set at 100 V and Gain set at 32 dB
Specifications C 5:4X
General
Number of channels 4 Peak total output all channels driven 500 W Peak outpu t voltage pe r channel 100 V Max. ou tput current p er channe l 5.6 Ar ms
Max. O utput Power
Per ch. (all ch.’s driven) 125 W 125 W 12 5 W 60 W Bridged per ch. 250 W 250 W 125 W n.r.
Perfo rmanc e with Ga in: 32 dB and VPL: 100 V
THD 20 Hz - 20 kHz for 1 W <0.1% THD at 1 kHz and 1 dB below clipping <0.05% Signal To Noise Ratio >112 dBA Channel separation (Crosstalk) at 1 kHz >70 dB Frequency response (1 W into 8 ohms) +0/-3 dB 6.8 Hz - 34 kHz Input impedance 20 kOhm Common Mode Rejection (CMR) >50 dB, 20 Hz to 20 kHz Output impedance @ 100 Hz 48 mOhm
Voltage P eak Limi ter (V PL), max . peak o utput
VPL, selectable per ch. (V) VPL, selectable when bridged ( V) Voltage Peak L imiter mode (per ch.) Hard / Soft
Gain and Level
Amplifier gain selectable (all channels) – rear-panel switches Default gain 32 dB Level adjustm ent (per ch.) Front-panel potentiometer, 21 position detented from -inf to 0 dB, hidden behind security panel/dust filter grille
Connectors and switches
Input connectors (per ch.) 3-pin Phoenix, electronically balanced Output connectors (per ch.) Barrier strip 2-pole screw terminals Output bridge mode A+B, C+D, E+F, G+H, inputs A, C, E, G are signal source High pass filter Fixed at 35 Hz, switchable per channe l NomadLink Intelligent fans (on/off) Yes, depending on presence of output signal Power on/of f and Rem ote enable on/off Individual switches on f ront panel Cooling Two fans, front-to-rear airflow, temperature controlled speed General Purpose Outputs (GPO) Contact Closure types, 2-pole Phoenix General Purpose Inputs (GPI) Contact Closure types, 2-pole Phoenix
Front-panel indicators
Common NomadLink Network; Power Average Limiter (PAL)
®
network On board, 2 x RJ45 connectors, IN and OUT
3)
1) 3)
1)
Per channel
Power
Operating vo ltage, 23 0 V / 115 V nominal Universal p ower supply 65-2 65 V Minimum power-up volt age, 230 V / 115 V 80 V Power Average Limiter (PAL) Power Factor Correction (PFC) Yes Soft sta rt / Inrus h current draw Yes / max. 5 A Mains connector IEC Inlet
Dimensions W: 483 mm (19”), H: 88 mm (2 U), D: 343 mm (13.5”) Weight 8.5 kg (18.75 lbs.) Finish Black painted steel chassis with gray painted steel front
2)
16 ohms
8 ohms 4 ohms 2 ohms
100, 63, 45, 32 V 200, 126, 90, 64 V
29, 32, 35, 38 dB
Signal present / High-impedance; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute
Yes
Approvals CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
Note 1): Automatic -6 dB gain compensation when bridging channels. Ch.’s A+B and/or C+D, E+F, G+H, can be bridged individually. Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to Operation Manual. Note 3): For sine waves, peak voltage output values translate to Vrms with the formula V/1.41 = Vrms. E.g. 100 V peak equals app. 70 V peak. Hence, outputs can be set for high-impedance loads without requiring a transformer. Note 4): Regarding n.r. (not recommended) notes: The amplifier will be fully operational in bridge-mode into 2 ohm and high impedance (Hi-Z) loads, but due to physical constraints in the construction, the max. output power will not be significanty higher than running individual channels and therefore this mode of operation is not recommended.
All specifications are subject to change without notice.
Hi-Z 70 Vrm s/100 V p eak Hi-Z 100 Vr ms/141 V pea k Hi-Z 140 Vrm s/20 0 V peak
125 W n.a. n.a.
4)
n.a. n.a 250 W
2)
; Power on
internationaL contact ▸ in fo@Labgruppe n.com | uS & cana da contact ▸ info@tcg-americaS.com
Lab.gru ppen ab Sweden
www.labgruppen.co m
Item no. TDS-C54X_V8