Voltage Peak Limiter Load vs Power Tables
C Series C 20:8X, C 10:8X, C 10:4X, C 5:4X: Dedicated Installation Amplifiers
C Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear- panel DIP-switch settings allow the output voltage
to be adjusted and consequently the output power available. The following tables provide information, for the listed C Series models, about
resultant output power at typical loads ( single-channel and bridged operation ) with the available VPL settings.
Lab.gruppen ab • Sweden
internationaL contact • info@Labgruppen.com | uS contact • infouS@tceLectronic.com
www.labgruppen.com
V peak Vrms
16 ! 8 ! 4 ! 2 !
Hi Z
100 V 100 71 *250 *250 **250 n.r. 250
63 V 63 45 125 250 **250 n.r. n.a.
45 V 45 32 60 125 250 **125 n.a.
32 V 32 23 30 60 125 **125 n.a.
* = PAL limited to this power when all channels driven
** = Current limited to this power
n.r. = Not recommended
n.a. = Not applicable
VPL Setting V peak Vrms
100 V 200 141 *500 **500 n.r. n.r. 500
63 V 126 90 500 **500 n.r. n.r. 500
45 V 90 64 250 500 **250 n.r. n.a.
32 V 64 45 125 250 **250 n.r. n.a.
* = PAL limited to this power when all channels driven
** = Current limited to this power
n.r. = Not recommended
n.a. = Not applicable
Output power bridged per two channels (W)
Output power per channel (W)
V peak
Vrms
16 ! 8 ! 4 ! 2 !
Hi Z
100 V 100 71 *125 *125 n.r. n.r. 125
63 V 63 45 125 *125 **125 n.r. n.a
45 V 45 32 60 125 **125 **60 n.a
32 V 32 23 30 60 125 **60 n.a
* = PAL limited to this power when all channels driven
** = Current limited to this power
n.r. = Not recommended
n.a.= Not applicable
VPL Setting
V peak
Vrms
16 ! 8 ! 4 ! 2 !
Hi Z
100 V 200 141 *250 **250 n.r. n.r. 250
63 V 126 90 **250 **250 n.r. n.r. 250
45 V 90 64 250 **250 **125 n.r. n.a.
32 V 64 45 125 250 **125 n.r. n.a.
* = PAL limited to this power when all channels driven
** Current limited to this power
n.r. = Not recommended
n.a.= Not applicable
Output power bridged per two channels (W)
Output power per channel (W)