LabGruppen 10000q-fp100f-10, 10000q-fp100f-10-1 Service Bulletin

Document type:
SERVICE BULLETIN
Created:
Page:
Technical Service Bulletin No. 16
Created by: Lab.gruppen AB Service Department Date: 100628 Reference no: Unstable rail voltage, not able to adjust rail voltage.
Affected models
Following models are affected by this technical service bulletin: C:16, C:28, C:48, C:68 & C:88. FP 4000, FP 6000Q, FP 7000, FP 9000, FP 10000Q, FP 13000 & FP 14000.
Affected boards/modules
SP100, SP130 and SP140.
Symptom
Unstable rail voltage, not able to adjust rail voltage. PSU clicking on and off all the time and PAL led lights up.
Solution
1. Check if there is contact between + rail and R32 & R34.
2. Check if there is contact between – rail and R33.
3. If not repair foil pattern and check D23, D24, D25, D26, D27, Q8, Q9 & Q10.
4. Update OVP circuit if needed, regarding to instruction (Only SP100 & SP130).