EMD 700.0
537 725 FC1
Contents
Conditions of guarantee
The conditions of guarantee applicable for this product are subject to those published by the representative in the relevant country. Details regarding same may be obtained from the dealer from whom the appliance was purchased. For claims under guarantee the sales receipt must be produced.
Proper use
The external EMD 700.0 motor may only be used for ventilating kitchens
with a cooker hood authorised by KÜPPERSBUSCH for this purpose. Improper use will result in the warranty becoming invalid and the termi­nation of the manufacturer’s liability.
The EMD 700.0 should only be fitted to a roof. Please pay particular at­tention to the instructions regarding installation and safety and also to any official regulations.
Applicable cooker hoods
The following KÜPPERSBUSCH cooker hoods can be used with the EMD 700.0:
- IKDEM 906.3
- IKDEM 966.1
- KDEM 906.3
- KDEM 966.1
- KDEM 965.1
- EDIP 644.0
- LBEM 835.0 / 635.0
Safety instructions
for connection and usage
KÜPPERSBUSCH appliances are manufactured in accordance with the ap­propriate safety regulations.
Installation, maintenance and repairs should only be carried out by an authorised technician, following the relevant safety regulations. Improper­ly performed work can endanger your safety.
Extraction appliances must not be fitted to smoke or fume chimneys or to shafts, which are used for ventilating rooms with fireplaces. Before ex­tracting fumes into a smoke or fume chimney which is not in use, plea­se obtain approval from your local chimney sweep.
When extracting fumes, it is important to follow any official regulations. The appliance should only be attached to a mains system which uses
the line voltage shown on the identification plate. The appliance should only be operated with an effective all-pole discon-
necting device with a contact gap of at least 3 mm, e. g. a fuse. Once installed, the mains plug must be accessible. Otherwise, the house-
hold fuse must be switched off when it is being cleaned or maintained. Please take note of the safety instructions for the cooker hood combined
with the motor.
for operation with heating appliances de­pendent on internally circulating air.
Affecting gas-, oil- or coal-fired heating appliances, instant water heaters, hot water tanks: When an exhaust air cooker hood is in operation, the air necessary for combustion may be taken from the other heat source and the danger of poisoning and/or explosion may arise.
When the hood and heating appliance are both in use in the same room, safe operation is only achieved as long as a negative pressure of
0.04 mbar is not exceeded. This will prevent back-suction of the heat source gases.
Make sure that sufficient volumes of combustion air may flow back into the room by means of non-airtight openings in windows and doors, venti­lation wall boxes (supplying/extracting air) or other technical devices, e.g. interlock devices. Example: When the window is closed, a switch stops the cooker hood from operating.
When making an assessment, always take into account all forms of ven­tilation in the house. If in doubt consult your local chimney sweep.
Conditions of guarantee. . . . . . . . . . . . . . . . . . . . . . . 7
Proper use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Applicable cooker hoods . . . . . . . . . . . . . . . . . . . . . . 7
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 7
for connection and usage . . . . . . . . . . . . . . . . . . . . 7
for operation with heating appliances dependent on internally circulating air.7
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Your appliance at glance . . . . . . . . . . . . . . . . . . . . . 8
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . 8
Installation preconditions . . . . . . . . . . . . . . . . . . . . 8
Preliminary work . . . . . . . . . . . . . . . . . . . . . . . 9
Attaching the roof penetration duct . . . . . . . . . . . . . . . . 9
Attaching the motor housing . . . . . . . . . . . . . . . . . . 9
Re-fitting the roofing tiles . . . . . . . . . . . . . . . . . . . . 9
Connecting the EMD 700.0 . . . . . . . . . . . . . . . . . . . 9
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Identification plate . . . . . . . . . . . . . . . . . . . . . . . 10
Notes on extraction paths . . . . . . . . . . . . . . . . . . . . 10
EMD 700.0 7