Operating modes
This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.
If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.
Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.
Circulating-air mode:
An activated carbon filter must be fitted
for this operating mode (see Filters and maintenance).
The complete installation set and
replacement filters can be obtained from specialist outlets.
The corresponding accessory numbers can be found at the end of these operating instructions.
The extractor-hood fan extracts the
kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen.
The grease filter absorbs the grease
particles in the kitchen vapours.
The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous substances in the cooking vapours.
Light / fan switches Filter drawer
Description of appliance
Operating instructions:
Operating modes
Exhaust-air mode:
The extractor-hood fan extracts the
kitchen vapours and conveys them through the grease filter into the atmosphere.
The grease filter absorbs the solid
particles in the kitchen vapours.
The kitchen is kept almost free of grease
and odours.
D
If the extractor hood is operated in
exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
ensure that there is an adequate air supply which the heater requires for
combustion. Safe operation is possible provided that the
partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar).
20
Before using for the first time
Important notes:
The Instructions for Use apply to several
versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.
This extractor hood complies with all
relevant safety regulations. Repairs should be carried out by
qualified technicians only.
Improper repairs may put the user at considerable risk.
Do not flambé food directly under the
extractor hood.
Risk of grease filter catching fire due
! to flames.
Restrictions apply to the use of the
extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).
Gas hobs / gas cookers
Always use gas hobs in a proper and
safe manner.
Important:
The flames from the gas hob must always be covered by pots or pans.
The intense heat generated by the gas flames could cause damage to the
!
extractor hood.
Before using your appliance for the first
time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance.
Please retain the operating and
installation instructions for a subsequent owner.
Do not use the appliance if damaged.The appliance is not intended for use
by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.
The appliance may be connected to
the mains by a qualified technician only.
Dispose of packaging materials
properly (see Installation instructions).
Light bulbs must always be fitted when
the extractor hood is in use.
Defective bulbs should be replaced
immediately to prevent the remaining bulbs from overloading.
Never operate the extractor hood
without a grease filter.
Overheated fat or oil can easily catch
fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.
21
Operating the extractor hood
The most effective method of removing
vapours produced during cooking is to:
Switch the ventilator ON
as soon as you begin cooking.
Switch the ventilator OFF
a few minutes after you have finished cooking.
The fans in this appliance can be swit-
ched to the desired setting by hand (manual mode) or can be controlled fully automatically with the automatic function according to your requirements (automatic mode).
Switching on manual mode:
Press the L or + button. The fan starts at Setting
}.
Switching over to automatic mode:
To switch from manual mode to
automatic mode at any time, press the Ü button.
Fan – off – Fan settings – lower –
Fan – on – Fan settings – higher –
Intermittent
ventilation
Light on / off
Display:
Fan settings / Intensive
setting
Saturation –
grease filter
#
Saturation –
activated carbon filter
r ã
Fan on / off
Switching on the fan settings/intensive setting:
1. To increase the fan settings or switch on
the intensive setting ç, press the + button.
The intensive setting operates at
maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to Setting
} after
10 minutes.
2. To switch off the intensive setting
ç or
switch back to fan settings
~ – } – |
and switch off the extractor hood completely, press the
button.
Appliances without automatic mode: Appliances with automatic mode:
(Ultraschall-Sensor)
Fan – off – Fan settings – lower –
Automatic mode / Manual mode
Fan – on – Fan settings – higher –
Intermittent ventilation
Light on / off
Display:
Fan settings / Intensive
setting
Saturation –
grease filter
#
Saturation –
activated carbon filter
r ã
Fan on / off
22
Operating the extractor hood
Switching on automatic mode:
Press the Übutton. The fan runs at least at Setting
|.
Fan settings:
If required, the optimum fan setting is
actuated automatically via a sensor.
The automatic function operates at
Settings
| – ~.
Intensive setting:
1. To switch on the intensive setting
ç
,
press the
+ button.
Automatic mode has been switched
off.
The intensive setting operates at
maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to the optimum fan setting after 10 minutes.
2. To switch off the intensive setting, press the
button.
Automatic mode has been switched
on again.
Switching over to manual mode:
To switch from automatic mode to
manual mode at any time, press the
Ü
button.
Intermittent ventilation
Used for ventilating the kitchen at hourly
intervals at the lowest fan setting, round the clock.
Switching on appliance:
Press the button and insert the filter drawer.
The fan runs for 5 minutes at Setting |,
then switches off for 55 minutes. This process is repeated every hour.
Switching off:
Press the button.