Kyocera 1001 Series, 06 1001 103 Instruction Manual

No.
: 205-03-330
取扱説明書
INSTRUCTION MANUAL
1001
圧着工具 Crimping Tool
06 1001 103
Series
O EDN19089 2019/04/15 H. Yoneno M. Isoe Y. Shimizu
NO EDN/DCN DATE PREPARED by CHECKED by APPROVED by
106-03-003
© 2019 KYOCERA Corporation
C
(mm)]
E
l
(mm)
r
06 1001 103 For 8283-3513 Contacts AWG#22-26
■Part Names
INSTRUCTION MANUAL
HAND CRIMPING TOOL
■Basic specification Part No. 06 1001 103
Weight Approx. 420g
Dimensions 220 (W) x 70 (H) x 25 (D) mm
■Crimping conditions
Please make sure that the tensile strength of a contact crimped by using this tool satisfies the following value.
Crimp height for
Position
A 22
B
■Applicable contact and wires
For special wires, please consult us separately.
Contact
60 8283
3513
XX 808
AWG No. of
applicable wire
24 26 2.0
Strip length 3.0 – 3.8mm
Style No. AWG No.
UL1061
strand
reference (mm)
Core wire
Coated wire
0.69 - 0.74 1.45 - 1.55
0.63 - 0.71 1.35 - 1.50
Wire
ore wire [No. of wires /
dia.
22 7/0.25 Ø 1.26 24 7/0.20 Ø 1.10 26 7/0.16 Ø 0.98
Tensile strength, minimum value (N)
4.0
3.0
xterna diameter of coated wire
<Instructions for use>
- When setting a contact into or removing it from the tool, do not hook the contact on the cable stopper or the anvil. Or the contact could be deformed.
- When binding wires, loosen the wires so that no stress could be applied to the contact directly.
- Set a contact in the right orientation.
- The ratchet is equipped so that the handles would not open until proper pressure is applied.
- In order to release the ratchet as an emergency measure against erroneous crimping, move the ratchet release lever in the direction as shown in the figure below.
Ratchet-release l eve
<Routine check>
1) After use, lubricate the teeth part with machine oil or etc.
2) Make sure that the handles open/close smoothly
without any clinging or biting at the anvil or the ratchet part.
3) If the impressing pressure of the ratchet is decreased during a long-term usage, adjust the ratchet. The ratchet unlock position could be changed by the ratchet adjustment screw and the fixing nut loosened and turned by using a “specialized tool”. After adjusted, be sure to tighten the nut. Before use it in the process, make sure that the crimping operation is performed properly in a trial.
1001 SERIES INSTRUCTION MANUAL No. 205-03-330 106-03-004
© 2019 KYOCERA Corporation
PAGE 4/5