Fuse
AUTO CURRENT
D.C. CURRENT SENSOR
INSTALLATION INSTRUCTIONS
S1
F
12V
IND
GND
Chassis
Ground
Chassis
Ground
The Auto Current F detects current and closes a
switch when the sensed current flows to provide a
remote indication. An electronic flasher interrupts
the indicator output approximately once per second
to provide a flashing indication.
Designed for applications where a remote indicator
must be illuminated when one or more lights or other
loads are energized. By detecting load current any
one , or more than one lamp, or other load will cause
the indicator to light. The indicator circuit contains
a relay which is operated by the sensor and flashing
circuit. Indicator currents as high as 5 amperes may
be driven by the relay.
S2
Indicator
Lamp
MODEL
NUMBER
091-22F-2
091-22F-3
091-22F-5
Compartment
Lights
Loads
Loads
ORDERING INFORMATION
RESIST
OHMS
.01
.01
.02
MIN. OPER.
AMPS
1.0
.25
.25
MAX. OPER.
AMPS
30
30
10
Door
Switch
Door
Switch
RATING 12V
Chassis
Ground
Chassis
Ground
SWITCH
5 AMP
5 AMP
5 AMP
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826