Kramer Electronics WP-306 User Manual

The Kramer WP-306 Wall Plate

Destination England and the rest
Germany)
Congratulations on purchasing your Kramer WP-306 Wall Plate which is ideal for boardrooms and presentation rooms.
The WP-306 is a single-gang wall plate insert.

WP-306 Wall Plate US Version

Figure 1 and Table 1 define the US version of the WP-306 Wall Plate.
EIA /TI A 568B
PIN Wire Color
1 Orange/White
2 Orange
3 Green/White
4 Blue
5 Blue/White
6 Green
7 Brown/White
8 Brown
Pair 1 4 and 5
Pair 2 1 and 2
Pair 3 3 and 6
Pair 4 7 and 8
Figure 2: RJ-45 Pinout (U.S.)

WP-306 Wall Plate EU/UK Versions

Figure 3 and Table 2 define the EU/UK version of the WP-306 Wall Plate.
Figure 1: WP-306 Wall Plate US Version Front and Rear View
# Feature Function
1 ON LED Lights red when receiving power (when no signal is detected); lights
2 HDMI IN Connector Connect to the HDMI digital source
3 IR OUT 3.5mm Mini Connector Connect to a machine via an IR Emitter. Note, that the IR output is
4 RJ-45 Connector Connect to the SV-552 Processor/Controller. Note that the WP-306
5 DC IN Power Connector Connect to the 12V power supply (supplied free)
green when receiving a signal
only compatible with the SV-552
requires B C-DGKat524 or BC-DGKat-623 cable for connection
Wiring the Twisted Pair RJ-45 Connector
The US versions of the wall plates are equipped with RJ-45 terminals. Figure 2 defines the STP pinout using a straight pin to pin cable with RJ-45 connectors. For STP cable, cable shielding must be connected/soldered to the connector shield.
Note: For cabling WP-306 wall plates, use either Kramer BCP-DGKat524 or BCP-DGKat623 STP cables.
Destination Belgium and Germany
of Europe (excluding Belgium and
Rear panel view
Figure 3: WP-306 Wall Plate EU/UK Version Front and Rear Views
Table 2: WP-306 Wall Plate EU/UK Version Front and Rear Features
# Feature Function
1 ON LED Lights red when receiving power (when no signal is
2 HDMI IN Connector Connect to the HDMI digital source
3 IR OUT 3.5mm Mini Connector Connect to a machine via an IR Emitter. Note, that the IR
4 Terminal Block
5 GROUND Connection Ring tongue terminal and grounding screw
6 GND +12V 2-pin Power Terminal Block Connect to the 12V power supply (included)
detected); lights green when receiving a signal
output is only compatible with the SV-552
Connect to SV-552. Note that the WP-306 requires BC-DGKat524 or BC-DGKat-623 cable for connection

Wiring the U.K. and European TP Terminal Blocks

2900-000772
3
The European wall plates are equipped with an easy plug-in terminal block to attach the twisted pair cables. Follow the colors of the color-coded sticker on these terminals for proper connection of the twisted pair cable.
Figure 4 defines the pinouts for the TP terminal block.
Figure 4: WP-306 Wall Plate EU/UK TP Terminal Block Pinouts
Notes:
WP-306
Wall Plate
Use the connector clips when removing the wires, not when inserting them
Each wire protrudes 9mm in length from the plastic insulation so that it can be easily connected. To
prevent the wires crossing, be sure that each wire is completely inserted
The cable ground shielding must be connected / soldered to the connector shield
Installation Instructions

Grounding the Wall Plate

Use the grounding screw to earth the chassis of the unit to the ground of the building. This prevents static electricity from interfering with the product’s performance.
Figure 5 defines the grounding screw components.
# Item
1 M3X6 screw
2 1/8" Toothed Lock Washer
3 M3 Ring Tongue Terminal
Figure 5: Grounding Screw Components
To ground the wall plate:
1. Connect the ring tongue terminal to the building grounding point wire. We recommend using a green-yellow AWG#18 wire, crimped with a proper hand-tool.
2. Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above.
3. Insert the M3x6 screw (through the two toothed lock washers and ring tongue terminal) into the grounding screw hole and tighten the screw.
For the latest information on our products and a list of Kramer distributors,
visit our Web site at
Uhttp://www.kramerelectronics.comU
PN:
Rev:
Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000772 REV 3
Loading...