Step 1: Check what’s in the box

TP-583Txr HDMI Line Transmitter or
1 Power adapter and cord
1 Quick start guide
TP-583Rxr HDMI Line Receiver
4 Rubber feet
1 Bracket set

Step 2: Get to know your TP-583Txr and TP-583Rxr

TP-583Txr
#
Feature
Function
1
IN LED
Lights green when an active source device input signal is detected.
2
OUT LED
Lights green when an active, far-end sink (acceptor) connection is detected via the HDBT link.
3 LINK LED
Lights green when an HDBT link is established with the HDBaseT receiver.
4
ON LED
Lights green when the device receives power.
5
LINE RJ-45 Connector
Connect to the RJ-45 HDBT LINE connector on a receiver (for example, TP-583Rxr, TP-780Rxr and so on).
6
HDMI IN Connector
Connect to an HDMI source.
7
SETUP DIP-switches
Set the operation DIP-switches.
8
RS-232 (G, Rx, Tx) 3-pin Terminal Block Connector
Connect to a laptop to control the receiver or perform firmware upgrade. Connect to a controller device (for example, SL-240C) to serially control a remote device (for example, the HDMI OUT acceptor) that is connected to TP-583Rxr.
9
IR 3.5mm Mini Jack Connector
Connect to an external infrared emitter / sensor.
10
12V DC Power Connector
12V DC connector for powering the unit.
Page 2
TP-583Rxr
#
Feature
Function
1
IN LED
Lights green when an active, far-end source device input signal is detected via the HDBT link.
2
OUT LED
Lights green when an active sink (acceptor) connection is detected.
3 LINK LED
Lights green when an HDBT link is established with the HDBaseT transmitter.
4
ON LED
Lights green when the device receives power.
5
LINE RJ-45 Connector
Connect to the RJ-45 HDBT LINE connector on a transmitter (for example, TP-583Txr, TP-780Txr and so on).
6
HDMI OUT Connector
Connect to an HDMI acceptor.
7
SETUP DIP-switches
Set the operation DIP-switches.
8
RS-232 (G, Rx, Tx) 3-pin Terminal Block Connector
Connect to a laptop to control the receiver or perform firmware upgrade. Connect to a serially controlled device (for example, the HDMI OUT acceptor) to enable its control by a remote controller device (for example, SL-240C) that is connected to TP-583Txr.
9
IR 3.5mm Mini Jack Connector
Connect to an external infrared emitter / sensor.
10
12V DC Power Connector
12V DC connector for powering the unit.

Step 3: Install TP-583Txr/TP-583Rxr

Install TP-583Txr/TP-583Rxr using one of the following methods:
Attach the rubber feet and place the unit on a flat surface.
Fasten a bracket (included) on each side of the unit and attach it to a flat surface.
For more information go to
www.kramerav.com/downloads/TP-583Txr, TP-583Rxr.
Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/TP-583Txr, TP-583Rxr).
Page 3

Step 4: Connect the inputs and outputs

Always switch OFF the power on each device before connecting it to your TP-583Txr/TP-583Rxr. For best results, we recommend that you always use Kramer high-performance cables to connect AV equipment to TP-583Txr/TP-583Rxr.
RJ-45 Pinout:
For HDBT cables, it is recommended that the cable ground shielding be connected/soldered to the connector shield:
PIN EIA /TIA 568B
PIN
Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
For optimum range and performance use the recommended Kramer cables available at
www.kramerav.com/product/TP-583Txr, TP-583Rxr.
Page 4
DIP-Switch Settings
The DIP-switches are used to:
Set the HDBT range.
Set the compression levels and resolutions.
Enable RS-232 signal extension.
Upgrade the firmware.
Determine IR signal pass-through.
All the DIP-switches are set to OFF (up) by default.
To use your TP-583Txr or TP-583Rxr with any other standard HDBaseT
extender (without compression), verify that DIP-switch 1B is OFF (up).
A – DIP-switch Settings
#
Feature
DIP-switch Settings
1A
Set HDBT Range
OFF (up) – HDBaseT normal range. ON (down) – HDBaseT ultra-long range (to enable increased range at a reduced bandwidth).
The ultra-long range mode is activated when on at least one of the devices DIP-switch 1 is set to ON.
2A
Set the Compression Level (for extended range)
OFF (up) – Standard compression level. ON (down) – High compression level for additional extension.
B – DIP-switch Settings
Changes to DIP-switches 2B and 3B only take effect after power cycling the device.
#
Feature
DIP-switch Settings
1B
Define Compressed Resolutions
OFF (up) – Compress signal resolutions higher than 1080p. ON (down) – Compress all signal resolutions to enable extended reach.
2B, 3B
Define RS-232 Function
OFF (up), OFF (up) – Embed RS-232 data and control signals over the extension line.
Other DIP-switch settings are reserved for firmware upgrade. For further details, contact support@kramerav.com.
4B
Define IR Pass-through
OFF (up) – Pass-through the IR signal to the IR port via IR cable. ON (down) – Add IR modulation to the IR output signal (applies only when the IR port is connected to an IR emitter cable).
The IR Pass-through DIP-switch setup depends on the IR control configuration. We recommend that you test which position best suits your application.

Step 5: Connect the power

Connect the 12V DC power adapter to TP-583Txr/TP-583Rxr and plug it into the mains electricity. Safety Instructions
Caution:
There are no operator serviceable parts inside the unit.
Warning:
Use only the Kramer Electronics power adapter that is provided with the unit.
Warning: