Kramer MODULAR TBUS-10xl User Manual

KRAMER ELECTRONICS LTD.
USER MANUAL
MODEL:
MODULAR TBUS-10xl
P/N: 2900-300688 Rev 4
TBUS-10xl – Contents
i
Contents
1 Introduction 1 2 Getting Started 2
2.1 Achieving the Best Performance 2
2.2 Glossary 3
2.3 Recycling Kramer Products 3
3 Overview 4 4 Your TBUS-10xl Enclosure 5
4.1 TBUS-10xl Optional Inner Frames 6
4.2 TBUS-10xl Optional Inserts 7
4.3 Power Socket Options 9
4.4 Power Cord Options 11
5 Installing the TBUS-10xl 12
5.1 Assembling the Inner Frame 12
5.2 Installing the Inner Frame 18
5.3 Cutting an Opening in the Table 19
5.4 Inserting the TBUS-10xl through the Cut Out Opening 20
5.5 Connecting the Cables 21
5.6 Inserting Pass-through Cables 21
5.7 Adjusting the Height of the Inner frame 22
6 Using the TBUS-10xl 23 7 Technical Specifications of the Assembled TBUS-10xl 24
Figures
Figure 1: TBUS-10xl Enclosure Top View 5 Figure 2: TBUS-10xl Inner Frame (P/N: 80-000028) 13 Figure 3: Installing the MegaTOOL 14 Figure 4: T-RC8IR (P/N: 80-000599) 15 Figure 5: Removing the RC-8IR Faceplate 15 Figure 6: T-RC8IR Installation 16 Figure 7: Removing the Mounting Plate Screws 17 Figure 8: T-RC-76/T-RC-78 Installation 17 Figure 9: Cut out Dimensions 19 Figure 10: Inserting TBUS-10xl into the Prepared Opening 20 Figure 11: TBUS-10xl Boardroom Installation 23
TBUS-10xl - Introduction
1
1
Note that the inner frame, power socket assembly, power cord and other inserts for the TBUS-10xl enclosure are purchased separately.
i

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Our 1,000-plus different models now appear in 11 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: Sierra Video Products.
Thank you for purchasing the Kramer TBUS-10xl enclosure, which is ideal for boardrooms, conference and training rooms!
2
TBUS-10xl - Getting Started
Go to www.kramerav.com to check for up-to-date user manuals, a complete list of Kramer wall plates and module connectors, application programs, and to check if firmware upgrades are available (where appropriate).
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
There are no operator serviceable parts inside the unit.
i
!
!

2 Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual

2.1 Achieving the Best Performance

To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
Position your Kramer TBUS-10xl away from moisture, excessive sunlight
and dust
TBUS-10xl - Getting Started
3
3
Inner frame:
The inner frame fits into the TBUS enclosure
Universal socket:
The Universal socket fits almost all power cords, worldwide
Insert:
The insert fits into the inner frame. Go to our Web site to check for a variety of single and dual sized inserts

2.2 Glossary

2.3 Recycling Kramer Products

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country
go to our recycling pages at www.kramerav.com/support/recycling/.
4
TBUS-10xl - Overview
Do not place heavy objects on top of the TBUS-10xl.
!

3 Overview

The Kramer TBUS-10xl is a high-quality, anodized aluminum, table-mounted connection bus enclosure for boardrooms and conference rooms. Its attractive enclosure is designed to provide maximum connectivity in the smallest possible footprint. The unit is sturdy, cost-effective, and easy to install.
The TBUS-10xl:
Has a modular design, letting you tailor the TBUS-10xl according to your
requirements
Is available with a black sand blasted anodized, silver sand blasted
anodized, or sliver brushed anodized aluminum lid with a special opening for cable pass-through (note, that other customized colors can also be ordered)
Includes height adjustment screw holes to set the inner frame (ordered
separately) to the desired height
Features a cover that opens and closes manually and retracts into the unit to
remain out of sight when the TBUS-10xl is in use. When closed, all cables and connectors are out-of-sight under the anodized cover
TBUS-10xl - Your TBUS-10xl Enclosure
5
5
#
Feature
Function
1
Outer Rim
Fits over the table surface. A protective rubber guard protects the outer rim during
shipping. Remove it before installing the unit
2
Inner Frame
Installed within the TBUS-10xl enclosure
3
Black Sand Blasted Anodized / Silver Sand Blasted Anodized / Silver Brushed Anodized Textured Aluminum Lid
Includes an opening for cable pass-through; covers the inner frame, leaving the table surface neat and tidy
4
Lid Housing
When opened, the lid retracts into the lid housing
5
Height Adjustment Screw holes
The screw holes on each side panel are used for mounting and adjusting the height of the Inner Frame

4 Your TBUS-10xl Enclosure

This section defines the TBUS-10xl enclosure and the Inner frame options.
Figure 1: TBUS-10xl Enclosure Top View
6
TBUS-10xl - Your TBUS-10xl Enclosure
#
Feature
Function
6
Table Clamping Set
Rubber Protectors
Protect the table surface when mounting the unit (one for each clamp)
7
Mounting Screws
For mounting onto table (one for each clamp)
8
Locking Butterfly Screws
Tighten to lock the mounting butterfly screw (one for each clamp)
9
Mounting Butterfly Screws
Tighten to secure the unit to the table surface (one for each clamp)
10
Mounting Clamps
Fit in the clamps slits after inserting the enclosure into the table – to secure the unit to the table surface (one for each clamp)
11
Bracket Slits
For attaching the two mounting clamps on opposite sides
12
Tie Holes
Insert the self-locking tie through the holes to fix the pass­through cables to the inside walls of the unit (4)
13
Enclosure
Inserted into the table cut out
Inner Frames for TBUS-10xl
Specifications (defines what you can include in this inner frame):
T10F-22M (P/N: 80-000028)
1 opening for 1 MegaTOOL, specially designed for the Kramer SID-X1
2 openings for 2 power sockets 1 blank insert 1 pass-through insert
T10F-33 (P/N: 80-000040)
2 openings for 3 power sockets (1 dual and 1 single) 2 blank inserts
1 pass-through insert
Custom made inner frames can be designed if required. Contact Kramer Electronics for more details.
i

4.1 TBUS-10xl Optional Inner Frames

The following inner frames can be installed in the TBUS-10xl enclosure:
TBUS-10xl - Your TBUS-10xl Enclosure
7
7
Accessories
Description
Inserts
You can install any wall plate device as well as any of the single or dual insertssee our Web site for details.
T-2INSERT (P/N: 80-00006699)
The T-2INSERT kit can be installed inside a single power socket opening and includes:
1 single cable pass-through insert 1 dual cable pass-through insert
T-RC8IR (P/N: 80-000599)
1 special panel to fit the Kramer RC-8IR Control Panel into the appropriate frame (P/N 80-000040 instead of two power sockets)

4.2 TBUS-10xl Optional Inserts

8
TBUS-10xl - Your TBUS-10xl Enclosure
Accessories
Description
T-RC-76 (P/N: 80-000080)
1 special panel to fit the Kramer RC-76 Control Panel into the appropriate frame (P/N 80-000040 instead of two power sockets)
T-RC-78 (P/N: 80-000081)
1 special panel to fit the Kramer RC-78 Control Panel into the appropriate frame (P/N 80-000040 instead of two power sockets)
TBUS-10xl - Your TBUS-10xl Enclosure
9
9
Socket Type
Power Specs
Universal:
TS-1U (80-000899)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug.
Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead.
Not compatible with South African plugs.
Socket Type
Power Specs
Socket Type
Power Specs
USA:
TS-1US (80-000999)
100-125V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
TS-1UK (91-000022)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France:
TS-1FR (80-001399)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel:
TS-1IL (80-001799)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU:
TS-1DE (80-001299)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
TS-1ZA (80-001699)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Italy:
TS-1IT (80-001499)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia:
TS-1AU (80-001599)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet

4.3 Power Socket Options

Inner frames support installing one or more of the following power socket assemblies. Note: The Brazilian power sockets are supplied as dual power sockets in a single power socket assembly (see table below).

4.3.1 Single Power Socket Assemblies

10
TBUS-10xl - Your TBUS-10xl Enclosure
Socket Type
Power Specs
Socket Type
Power Specs
Switzerland
TS-1CH (80-000027)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil
TS-BR (80-000034)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Socket Type
Power Specs
Universal:
TS-2U (80-001899)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA:
TS-2US (80-001999)
100-125V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France:
TS-2FR (80-002299)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU:
TS-2DE (80-002199)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
TS-2IT (80-002399)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
TS-2CH (80-000026)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
UK
TS-2UK (91-000023)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel:
TS-2IL (80-002699)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet

4.3.2 Dual Power Socket Assemblies

TBUS-10xl - Your TBUS-10xl Enclosure
11
11
Socket Type
Power Specs
South Africa:
TS-2ZA (80-002599)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Australia:
TS-2AU (80-002499)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Power Cord Type
Description
P/N
6ft/110V (North America)
C-AC/US (110V)
91-000099
6ft/125V (Japan)
C-AC/JP (125V)
91-000699
6ft/220V (Europe)
C-AC/EU (220V)
91-000199
6ft/220V (Israel)
C-AC/IL (220V)
91-000999
6ft/250V (UK)
C-AC/UK (250V)
91-000299
6ft/250V (India)
C-AC/IN (250V)
91-001099
6ft/250V/10A (China)
C-AC/CN (250V)
91-001199
6ft/250V/10A (South Africa)
C-AC/ZA (250V)
91-001299
Power Cord Type
Description
P/N
110V Y-version (6ft), North America
C-ACY/US
91-000399
220V Y-version (6ft), Europe
C-ACY/EU
91-000499
240V Y-version (6ft), UK
C-ACY/UK
91-000599

4.4 Power Cord Options

You can order any of the following power cords to use with a modular TBUS:
To use one power cord for a 3-socket configuration on the T10F-33, you can order any of the following types of power cords separately:
12
TBUS-10xl - Installing the TBUS-10xl
Each module kit comes with detailed assembly instructions.
i

5 Installing the TBUS-10xl

To install the TBUS-10xl perform the following steps:
1. Assemble the inner frame (see Section 5.1).
2. Install the inner frame (see Section 5.2).
3. Cut an opening in the table (see Section 5.3).
4. Insert the unit through the opening and secure to the table (see Section 5.4).
5. Connect the cables (see Section 5.5).
6. Insert pass-through cables (see Section 5.6)
7. Adjust the height of the inner frame (see Section 5.7).

5.1 Assembling the Inner Frame

The modules mounted on the inner frame can include a MegaTOOL, single inserts and/or dual inserts as well as a power socket (in some models). This section describes how to assemble these modules.

5.1.1 Mounting the Inserts

You can rearrange or remove any of the plates mounted on the inner frame and replace them with Kramer passive wall plates or connector modules for interfacing A/V type signals.
To mount a Kramer insert or connector module:
1. Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate.
2. Place the required Kramer insert over the opening, insert the two screws to fix the Kramer insert in place, and tighten them.
TBUS-10xl - Installing the TBUS-10xl
13
13
#
Feature
Function
1
Blank Plates
Two blank covers that can be replaced with wall plates as required
2
Dual Power Socket Opening
Suitable for 2 power sockets or optional TBUS insert kits (for example, the T-RC18 insert kit)
3
Split Brackets
Support the split grommet for the pass through-cables
4
Power Socket Opening
Suitable for a single power socket or the optional insert kit for TBUS
5
Adjustable Height Screw Holes
For adjusting the height of the Inner frame
Power socket kits come with assembly instructions.
i
Figure 2: TBUS-10xl Inner Frame (P/N: 80-000028)

5.1.2 Mounting the Power Socket Assemblies

To mount the power socket, place the power socket under the frame in its appropriate place and tighten with the two screws (supplied).
14
TBUS-10xl - Installing the TBUS-10xl
The T-2INSERT comes with assembly instructions.
i

5.1.3 Mounting the T-2INSERT

The T-2INSERT optional insert kit lets you add 2 more inserts to the TBUS configuration of the TBUS instead of a power socket. To mount the T-2INSERT, place the T-2INSERT under the frame in its appropriate place and tighten with the two screws (supplied).

5.1.4 Mounting a MegaTOOL

To install a MegaTOOL, as shown in Figure 3:
1. Screw the supplied TOOL brackets to their designated places (one on each side).
2. Insert the MegaTOOL, from beneath, through the MegaTOOL opening.
3. Screw the screws (one on each side) through the inner frame holes and TOOL brackets.
Figure 3: Installing the MegaTOOL
TBUS-10xl - Installing the TBUS-10xl
15
15
Faceplate Attachment hole
Faceplate Attachment hole
Inner Frame Attachment hole
Inner Frame Attachment hole
IR IN Opening

5.1.5 Mounting an RC-8IR Device

The Kramer T-RC8IR for the TBUS-10xl Table Connection bus is used to fit the Kramer RC-8IR Control Panel into the appropriate frame (P/N 80-000040).
Figure 4: T-RC8IR (P/N: 80-000599)
To mount the RC-8IR, do the following
1. Before installing the T-RC8IR, unscrew the two faceplate attachment screws and remove the RC-8IR faceplate.
Figure 5: Removing the RC-8IR Faceplate
16
TBUS-10xl - Installing the TBUS-10xl
The T-RC8IR comes with assembly instructions.
i
2. Place the T-RC8IR over the RC-8IR enclosure so that both faceplate holes are aligned with the faceplate holes on the RC-8IR enclosure and the IR IN receiver fits into the IR IN opening.
3. Insert the faceplate screws through the T-RC8IR and RC-8IR enclosure faceplate holes, and tighten.
Figure 6: T-RC8IR Installation
4. Place the assembled T-RC8IR + RC-8IR under the dual socket opening.
5. Insert the two screws (supplied with the kit) to fix the T-RC8IR in place, and tighten them.
TBUS-10xl - Installing the TBUS-10xl
17
17
Note that the T-RC-76 installation example also applies to the T-RC-78.
i

5.1.6 Mounting RC-76 and RC-78 Devices

To install the T-RC-76/T-RC-78 insert:
1. Remove the design frame from the device by removing the two mounting plate screws (see Figure 7) and remove the mounting plate. Put the screws aside.
Figure 7: Removing the Mounting Plate Screws
2. Fit the T-RC-76 over the buttons of the RC-76; insert the two mounting plate screws through the T-RC-76 mounting bracket screw holes and tighten them (see Figure 8).
Figure 8: T-RC-76/T-RC-78 Installation
3. Place the assembled T-RC-76 + RC-76 under the dual socket opening.
18
TBUS-10xl - Installing the TBUS-10xl
The T-RC-76 and T-RC-78 come with assembly instructions.
Inner frame kits come with assembly instructions.
i
i
4. Insert the two screws (supplied with the kit) to fix the T-RC-76/T-RC-78 in place, and tighten them.
5. Install the inner frame (when configuration is complete) according to the specific TBUS inner frame installation instructions.

5.2 Installing the Inner Frame

To install the inner frame:
1. Place the inner frame inside the TBUS-10xl enclosure.
2. Set the required height using your fingers to bring the inner frame to the desired position, screw and tighten it in place using the height adjustment screws (supplied with the inner frame).
TBUS-10xl - Installing the TBUS-10xl
19
19
The thickness of the table should be 76.2mm / 3 inches or less.
Kramer Electronics is not responsible for any damage caused to the table.
i
!

5.3 Cutting an Opening in the Table

To cut an opening in the table:
1. Place the cut out template (that is included with your TBUS-10xl) on the surface of the table exactly where you want to install the TBUS-10xl.
2. Attach the template to the table with the included screws (if using the cut out template).
3. Following the inside edge of the template, cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 9 (not to scale).
Figure 9: Cut out Dimensions
4. Unscrew and remove the template from the surface of the table and clean the table surface. Take care not to damage the table. If needed, you can download a full-scale template from our Web site.
20
TBUS-10xl - Installing the TBUS-10xl

5.4 Inserting the TBUS-10xl through the Cut Out Opening

To install TBUS-10xl in the opening:
1. Remove the protective rubber guard from around the outer rim of the TBUS-10xl housing. Beware of the sharp edge!
2. Carefully insert the unit into the prepared opening (see Figure 10).
3. Take the support clamps under the table and place them into the support clamp grooves on both sides of the unit (see Figure 1).
4. Verify proper alignment of the unit before tightening the mounting screws.
5. Tighten both mounting butterfly screws upward until they reach the table surface (from underneath). Tighten firmly (see Figure 10).
6. Tighten the locking butterfly screws downward until tight against the mounting bracket.
Figure 10: Inserting TBUS-10xl into the Prepared Opening
TBUS-10xl - Installing the TBUS-10xl
21
21

5.5 Connecting the Cables

When replacing blank inserts with connector inserts (for example, VGA, audio, HDMI and so on):
1. Insert the cables to their appropriate connectors from underneath.
2. Secure the cables to the tie holes using the included self-locking ties. Do not secure the cables too tightly or too loosely. Leave a small amount of slack.
After the TBUS-10xl is connected to mains power and the proper cables, it is ready for use.

5.6 Inserting Pass-through Cables

When replacing inserts with the pass-through insert, for example, to connect a laptop, do the following:
1. Remove the two screws attaching the split pass-through bracket.
2. Remove the split grommet.
3. Insert the cable through the rectangular opening.
4. Open the split grommet slightly and insert the required cables.
5. Place the split bracket around the grommet and position this assembly over the Inner Frame.
6. Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame.
7. Insert the self-locking ties through the tie holes to secure the cables to the inside walls of the enclosure.
22
TBUS-10xl - Installing the TBUS-10xl

5.7 Adjusting the Height of the Inner frame

If needed, you can adjust the inner frame height to accommodate large or bulky cables. To adjust, perform the following:
1. Remove the four height adjustment screws, while supporting the surface from underneath with your fingers.
2. Raise or lower the inner frame to the required height, insert the screws, and tighten them in place.
TBUS-10xl - Using the TBUS-10xl
23
23

6 Using the TBUS-10xl

Once the TBUS-10xl is installed, you can easily customize it to suit your own requirements by plugging in the required A/V equipment, as illustrated in the example in Figure 11.
Figure 11: TBUS-10xl Boardroom Installation
24
TBUS-10xl - Technical Specifications of the Assembled TBUS-10xl
POWER SOURCE (AC power limits):
Single Socket Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug. Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France (you should order country specific sockets instead). Not compatible with South African plugs.
USA
100-125V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Dual Power Kit Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA
100-125V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
7 Technical Specifications of the Assembled
TBUS-10xl
TBUS-10xl - Technical Specifications of the Assembled TBUS-10xl
25
25
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
FUSE RATING:
T 6.3A 250V
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
-40° to +70°C (-40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
STORAGE HUMIDITY RANGE:
5 to 95% RHL, non-condensing
DIMENSIONS:
Top plate: 171.6mm x 261mm (6.8" x 10.3") W, D Enclosure: 203mm x 121mm x 130mm (8.0" x 4.8" x 5.1")
W, D, H
WEIGHT:
1.35kg (2.98lbs) approx. Table clamps: 0.25kg (0.55lbs)
ACCESSORIES:
Six self-locking ties, cut out template, template screws
OPTIONS:
Inner frames, passive wall plates and interfaces, power socket kits, power cord, T-2INSERT kit, T-RC-8IR kit, T-RC-76 kit, T-RC-78 kit, Kramer K-Able Box (furniture-
mounted cable extension)
Specifications are subject to change without notice at www.kramerav.com
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerav.com E-mail: info@kramerel.com
P/N:
2900-300688
Rev:
4
!
SAFETY WARNING Disconnect the unit from the power supply before opening and servicing
Loading...