Note that the inner frame, power socket assembly, power cord and
other inserts for the TBUS-10xl enclosure are purchased
separately.
i
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront video, audio, presentation, and broadcasting professionals
on a daily basis. In recent years, we have redesigned and upgraded most of our
line, making the best even better!
Our 1,000-plus different models now appear in 11 groups that are clearly defined
by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:
Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11:
Sierra Video Products.
Thank you for purchasing the Kramer TBUS-10xl enclosure, which is ideal for
boardrooms, conference and training rooms!
2
TBUS-10xl - Getting Started
Go to www.kramerav.com to check for up-to-date user manuals, a
complete list of Kramer wall plates and module connectors,
application programs, and to check if firmware upgrades are
available (where appropriate).
This equipment is to be used only inside a building. It may only be
connected to other equipment that is installed inside a building.
There are no operator serviceable parts inside the unit.
i
!
!
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual
2.1 Achieving the Best Performance
To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in
signal quality due to poor matching, and elevated noise levels (often
associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
Position your Kramer TBUS-10xl away from moisture, excessive sunlight
and dust
TBUS-10xl - Getting Started
3
3
Inner frame:
The inner frame fits into the TBUS enclosure
Universal socket:
The Universal socket fits almost all power cords, worldwide
Insert:
The insert fits into the inner frame. Go to our Web site to check for a
variety of single and dual sized inserts
2.2 Glossary
2.3 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
aims to reduce the amount of WEEE sent for disposal to landfill or incineration by
requiring it to be collected and recycled. To comply with the WEEE Directive,
Kramer Electronics has made arrangements with the European Advanced
Recycling Network (EARN) and will cover any costs of treatment, recycling and
recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country
go to our recycling pages at www.kramerav.com/support/recycling/.
4
TBUS-10xl - Overview
Do not place heavy objects on top of the TBUS-10xl.
!
3 Overview
The Kramer TBUS-10xl is a high-quality, anodized aluminum, table-mounted
connection bus enclosure for boardrooms and conference rooms. Its attractive
enclosure is designed to provide maximum connectivity in the smallest possible
footprint. The unit is sturdy, cost-effective, and easy to install.
The TBUS-10xl:
Has a modular design, letting you tailor the TBUS-10xl according to your
requirements
Is available with a black sand blasted anodized, silver sand blasted
anodized, or sliver brushed anodized aluminum lid with a special opening for
cable pass-through (note, that other customized colors can also be ordered)
Includes height adjustment screw holes to set the inner frame (ordered
separately) to the desired height
Features a cover that opens and closes manually and retracts into the unit to
remain out of sight when the TBUS-10xl is in use. When closed, all cables
and connectors are out-of-sight under the anodized cover
TBUS-10xl - Your TBUS-10xl Enclosure
5
5
#
Feature
Function
1
Outer Rim
Fits over the table surface.
A protective rubber guard protects the outer rim during
shipping. Remove it before installing the unit
2
Inner Frame
Installed within the TBUS-10xl enclosure
3
Black Sand Blasted
Anodized / Silver Sand
Blasted Anodized /
Silver Brushed
Anodized Textured
Aluminum Lid
Includes an opening for cable pass-through; covers the inner
frame, leaving the table surface neat and tidy
4
Lid Housing
When opened, the lid retracts into the lid housing
5
Height Adjustment
Screw holes
The screw holes on each side panel are used for mounting
and adjusting the height of the Inner Frame
4 Your TBUS-10xl Enclosure
This section defines the TBUS-10xl enclosure and the Inner frame options.
Figure 1: TBUS-10xl Enclosure Top View
6
TBUS-10xl - Your TBUS-10xl Enclosure
#
Feature
Function
6
Table Clamping Set
Rubber Protectors
Protect the table surface when mounting the unit (one for
each clamp)
7
Mounting Screws
For mounting onto table (one for each clamp)
8
Locking Butterfly
Screws
Tighten to lock the mounting butterfly screw (one for each
clamp)
9
Mounting Butterfly
Screws
Tighten to secure the unit to the table surface (one for each
clamp)
10
Mounting Clamps
Fit in the clamps slits after inserting the enclosure into the
table – to secure the unit to the table surface (one for each
clamp)
11
Bracket Slits
For attaching the two mounting clamps on opposite sides
12
Tie Holes
Insert the self-locking tie through the holes to fix the passthrough cables to the inside walls of the unit (4)
13
Enclosure
Inserted into the table cut out
Inner Frames for TBUS-10xl
Specifications (defines what you can
include in this inner frame):
T10F-22M (P/N: 80-000028)
1 opening for 1 MegaTOOL, specially
designed for the Kramer SID-X1
2 openings for 2 power sockets
1 blank insert
1 pass-through insert
T10F-33 (P/N: 80-000040)
2 openings for 3 power sockets (1 dual and
1 single)
2 blank inserts
1 pass-through insert
Custom made inner frames can be designed if required.
Contact Kramer Electronics for more details.
i
4.1 TBUS-10xl Optional Inner Frames
The following inner frames can be installed in the TBUS-10xl enclosure:
TBUS-10xl - Your TBUS-10xl Enclosure
7
7
Accessories
Description
Inserts
You can install any wall plate device as well as any of
the single or dual inserts—see our Web site for details.
T-2INSERT (P/N: 80-00006699)
The T-2INSERT kit can be installed inside a single
power socket opening and includes:
1 single cable pass-through insert
1 dual cable pass-through insert
T-RC8IR (P/N: 80-000599)
1 special panel to fit the Kramer RC-8IR Control Panel
into the appropriate frame (P/N 80-000040 instead of
two power sockets)
4.2 TBUS-10xl Optional Inserts
8
TBUS-10xl - Your TBUS-10xl Enclosure
Accessories
Description
T-RC-76 (P/N: 80-000080)
1 special panel to fit the Kramer RC-76 Control Panel
into the appropriate frame (P/N 80-000040 instead of
two power sockets)
T-RC-78 (P/N: 80-000081)
1 special panel to fit the Kramer RC-78 Control Panel
into the appropriate frame (P/N 80-000040 instead of
two power sockets)
TBUS-10xl - Your TBUS-10xl Enclosure
9
9
Socket Type
Power Specs
Universal:
TS-1U (80-000899)
100-240V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
Fully compatible with power plugs in the
UK, India, Italy and Denmark, as well as with
the 2-prong Europlug.
Partially compatible (if the polarity is
reversed) with plugs in China, Switzerland,
Israel and the USA. The universal socket
does not supply grounding to plugs in
Central Europe and France and so you
should order country specific sockets
instead.
Not compatible with South African plugs.
Socket Type
Power Specs
Socket Type
Power Specs
USA:
TS-1US (80-000999)
100-125V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
UK
TS-1UK (91-000022)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and
France:
TS-1FR (80-001399)
100-240V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
Israel:
TS-1IL (80-001799)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
Germany and EU:
TS-1DE (80-001299)
100-240V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
South Africa
TS-1ZA (80-001699)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
Italy:
TS-1IT (80-001499)
100-240V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
Australia:
TS-1AU (80-001599)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
4.3 Power Socket Options
Inner frames support installing one or more of the following power socket
assemblies.
Note: The Brazilian power sockets are supplied as dual power sockets in a single
power socket assembly (see table below).
4.3.1 Single Power Socket Assemblies
10
TBUS-10xl - Your TBUS-10xl Enclosure
Socket Type
Power Specs
Socket Type
Power Specs
Switzerland
TS-1CH (80-000027)
100-240V AC, 50/60Hz,
5A
Maximum 5A per power
outlet
Brazil
TS-BR (80-000034)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power
outlet
Socket Type
Power Specs
Universal:
TS-2U (80-001899)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA:
TS-2US (80-001999)
100-125V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France:
TS-2FR (80-002299)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU:
TS-2DE (80-002199)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
TS-2IT (80-002399)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
TS-2CH (80-000026)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
UK
TS-2UK (91-000023)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel:
TS-2IL (80-002699)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
4.3.2 Dual Power Socket Assemblies
TBUS-10xl - Your TBUS-10xl Enclosure
11
11
Socket Type
Power Specs
South Africa:
TS-2ZA (80-002599)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Australia:
TS-2AU (80-002499)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Power Cord Type
Description
P/N
6ft/110V (North America)
C-AC/US (110V)
91-000099
6ft/125V (Japan)
C-AC/JP (125V)
91-000699
6ft/220V (Europe)
C-AC/EU (220V)
91-000199
6ft/220V (Israel)
C-AC/IL (220V)
91-000999
6ft/250V (UK)
C-AC/UK (250V)
91-000299
6ft/250V (India)
C-AC/IN (250V)
91-001099
6ft/250V/10A (China)
C-AC/CN (250V)
91-001199
6ft/250V/10A (South Africa)
C-AC/ZA (250V)
91-001299
Power Cord Type
Description
P/N
110V Y-version (6ft), North America
C-ACY/US
91-000399
220V Y-version (6ft), Europe
C-ACY/EU
91-000499
240V Y-version (6ft), UK
C-ACY/UK
91-000599
4.4 Power Cord Options
You can order any of the following power cords to use with a modular TBUS:
To use one power cord for a 3-socket configuration on the T10F-33, you can order
any of the following types of power cords separately:
12
TBUS-10xl - Installing the TBUS-10xl
Each module kit comes with detailed assembly instructions.
i
5 Installing the TBUS-10xl
To install the TBUS-10xl perform the following steps:
1. Assemble the inner frame (see Section 5.1).
2. Install the inner frame (see Section 5.2).
3. Cut an opening in the table (see Section 5.3).
4. Insert the unit through the opening and secure to the table (see Section 5.4).
5. Connect the cables (see Section 5.5).
6. Insert pass-through cables (see Section 5.6)
7. Adjust the height of the inner frame (see Section 5.7).
5.1 Assembling the Inner Frame
The modules mounted on the inner frame can include a MegaTOOL, single inserts
and/or dual inserts as well as a power socket (in some models). This section
describes how to assemble these modules.
5.1.1 Mounting the Inserts
You can rearrange or remove any of the plates mounted on the inner frame and
replace them with Kramer passive wall plates or connector modules for interfacing
A/V type signals.
To mount a Kramer insert or connector module:
1. Unscrew the two screws that fasten the blank plate to the inner frame and
remove the blank plate.
2. Place the required Kramer insert over the opening, insert the two screws to
fix the Kramer insert in place, and tighten them.
TBUS-10xl - Installing the TBUS-10xl
13
13
#
Feature
Function
1
Blank Plates
Two blank covers that can be replaced with wall plates as
required
2
Dual Power
Socket Opening
Suitable for 2 power sockets or optional TBUS insert kits (for
example, the T-RC18 insert kit)
3
Split Brackets
Support the split grommet for the pass through-cables
4
Power Socket
Opening
Suitable for a single power socket or the optional insert kit for
TBUS
5
Adjustable Height
Screw Holes
For adjusting the height of the Inner frame
Power socket kits come with assembly instructions.
i
Figure 2: TBUS-10xlInner Frame (P/N: 80-000028)
5.1.2 Mounting the Power Socket Assemblies
To mount the power socket, place the power socket under the frame in its
appropriate place and tighten with the two screws (supplied).
14
TBUS-10xl - Installing the TBUS-10xl
The T-2INSERT comes with assembly instructions.
i
5.1.3 Mounting the T-2INSERT
The T-2INSERT optional insert kit lets you add 2 more inserts to the TBUS
configuration of the TBUS instead of a power socket.
To mount the T-2INSERT, place the T-2INSERT under the frame in its appropriate
place and tighten with the two screws (supplied).
5.1.4 Mounting a MegaTOOL
To install a MegaTOOL, as shown in Figure 3:
1. Screw the supplied TOOL brackets to their designated places (one on each
side).
2. Insert the MegaTOOL, from beneath, through the MegaTOOL opening.
3. Screw the screws (one on each side) through the inner frame holes and
TOOL brackets.
Figure 3: Installing the MegaTOOL
TBUS-10xl - Installing the TBUS-10xl
15
15
Faceplate Attachment hole
Faceplate Attachment hole
Inner Frame Attachment hole
Inner Frame Attachment hole
IR IN Opening
5.1.5 Mounting an RC-8IR Device
The Kramer T-RC8IR for the TBUS-10xl Table Connection bus is used to fit the
Kramer RC-8IR Control Panel into the appropriate frame (P/N 80-000040).
Figure 4: T-RC8IR (P/N: 80-000599)
To mount the RC-8IR, do the following
1. Before installing the T-RC8IR, unscrew the two faceplate attachment screws
and remove the RC-8IR faceplate.
Figure 5: Removing the RC-8IR Faceplate
16
TBUS-10xl - Installing the TBUS-10xl
The T-RC8IR comes with assembly instructions.
i
2. Place the T-RC8IR over the RC-8IR enclosure so that both faceplate holes
are aligned with the faceplate holes on the RC-8IR enclosure and the IR IN
receiver fits into the IR IN opening.
3. Insert the faceplate screws through the T-RC8IR and RC-8IR enclosure
faceplate holes, and tighten.
Figure 6: T-RC8IR Installation
4. Place the assembled T-RC8IR + RC-8IR under the dual socket opening.
5. Insert the two screws (supplied with the kit) to fix the T-RC8IR in place, and
tighten them.
TBUS-10xl - Installing the TBUS-10xl
17
17
Note that the T-RC-76 installation example also applies
to the T-RC-78.
i
5.1.6 Mounting RC-76 and RC-78 Devices
To install the T-RC-76/T-RC-78 insert:
1. Remove the design frame from the device by removing the two mounting
plate screws (see Figure 7) and remove the mounting plate. Put the screws
aside.
Figure 7: Removing the Mounting Plate Screws
2. Fit the T-RC-76 over the buttons of the RC-76; insert the two mounting plate
screws through the T-RC-76 mounting bracket screw holes and tighten them
(see Figure 8).
Figure 8: T-RC-76/T-RC-78 Installation
3. Place the assembled T-RC-76 + RC-76 under the dual socket opening.
18
TBUS-10xl - Installing the TBUS-10xl
The T-RC-76 and T-RC-78 come with assembly instructions.
Inner frame kits come with assembly instructions.
i
i
4. Insert the two screws (supplied with the kit) to fix the T-RC-76/T-RC-78 in
place, and tighten them.
5. Install the inner frame (when configuration is complete) according to the
specific TBUS inner frame installation instructions.
5.2 Installing the Inner Frame
To install the inner frame:
1. Place the inner frame inside the TBUS-10xl enclosure.
2. Set the required height using your fingers to bring the inner frame to the
desired position, screw and tighten it in place using the height adjustment
screws (supplied with the inner frame).
TBUS-10xl - Installing the TBUS-10xl
19
19
The thickness of the table should be 76.2mm / 3 inches or less.
Kramer Electronics is not responsible for any damage caused to the
table.
i
!
5.3 Cutting an Opening in the Table
To cut an opening in the table:
1. Place the cut out template (that is included with your TBUS-10xl) on the
surface of the table exactly where you want to install the TBUS-10xl.
2. Attach the template to the table with the included screws (if using the cut out
template).
3. Following the inside edge of the template, cut a hole in the table surface
with a sabre or keyhole saw according to the dimensions shown in Figure 9
(not to scale).
Figure 9: Cut out Dimensions
4. Unscrew and remove the template from the surface of the table and clean
the table surface.
Take care not to damage the table.
If needed, you can download a full-scale template from our Web site.
20
TBUS-10xl - Installing the TBUS-10xl
5.4 Inserting the TBUS-10xl through the Cut Out Opening
To install TBUS-10xl in the opening:
1. Remove the protective rubber guard from around the outer rim of the
TBUS-10xl housing. Beware of the sharp edge!
2. Carefully insert the unit into the prepared opening (see Figure 10).
3. Take the support clamps under the table and place them into the support
clamp grooves on both sides of the unit (see Figure 1).
4. Verify proper alignment of the unit before tightening the mounting screws.
5. Tighten both mounting butterfly screws upward until they reach the table
surface (from underneath). Tighten firmly (see Figure 10).
6. Tighten the locking butterfly screws downward until tight against the
mounting bracket.
Figure 10: Inserting TBUS-10xl into the Prepared Opening
TBUS-10xl - Installing the TBUS-10xl
21
21
5.5 Connecting the Cables
When replacing blank inserts with connector inserts (for example, VGA, audio,
HDMI and so on):
1. Insert the cables to their appropriate connectors from underneath.
2. Secure the cables to the tie holes using the included self-locking ties.
Do not secure the cables too tightly or too loosely. Leave a small amount of
slack.
After the TBUS-10xl is connected to mains power and the proper cables, it is ready for
use.
5.6 Inserting Pass-through Cables
When replacing inserts with the pass-through insert, for example, to connect a
laptop, do the following:
1. Remove the two screws attaching the split pass-through bracket.
2. Remove the split grommet.
3. Insert the cable through the rectangular opening.
4. Open the split grommet slightly and insert the required cables.
5. Place the split bracket around the grommet and position this assembly over
the Inner Frame.
6. Place the two screws appropriately and tighten the split bracket together
with the grommet and inserted cables to the inner frame.
7. Insert the self-locking ties through the tie holes to secure the cables to the
inside walls of the enclosure.
22
TBUS-10xl - Installing the TBUS-10xl
5.7 Adjusting the Height of the Inner frame
If needed, you can adjust the inner frame height to accommodate large or bulky
cables. To adjust, perform the following:
1. Remove the four height adjustment screws, while supporting the surface
from underneath with your fingers.
2. Raise or lower the inner frame to the required height, insert the screws, and
tighten them in place.
TBUS-10xl - Using the TBUS-10xl
23
23
6 Using the TBUS-10xl
Once the TBUS-10xl is installed, you can easily customize it to suit your own
requirements by plugging in the required A/V equipment, as illustrated in the
example in Figure 11.
Figure 11: TBUS-10xl Boardroom Installation
24
TBUS-10xl - Technical Specifications of the Assembled TBUS-10xl
POWER SOURCE
(AC power limits):
Single Socket Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and
Denmark, as well as with the 2-prong Europlug.
Partially compatible (if the polarity is reversed) with plugs in
China, Switzerland, Israel and the USA. The universal socket
does not supply grounding to plugs in Central Europe and
France (you should order country specific sockets instead).
Not compatible with South African plugs.
USA
100-125V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Dual Power Kit Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA
100-125V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
7 Technical Specifications of the Assembled
TBUS-10xl
TBUS-10xl - Technical Specifications of the Assembled TBUS-10xl
25
25
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
FUSE RATING:
T 6.3A 250V
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
-40° to +70°C (-40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
STORAGE HUMIDITY RANGE:
5 to 95% RHL, non-condensing
DIMENSIONS:
Top plate: 171.6mm x 261mm (6.8" x 10.3") W, D