Kramer KR-TBUS-4XLB TBUS-4XL(B) User Manual

KRAMER ELECTRONICS LTD.
USER MANUAL
MODEL:
TBUS-4xl
P/N: 2900-300067 Rev 3
TBUS-4xl – Contents
i
Contents
1 Introduction 1 2 Getting Started 2
2.1 Achieving the Best Performance 2
2.2 Glossary 2
3 Overview 3 4 Your TBUS-4xl Enclosure 4
4.1 TBUS-4xl Optional Inner Frames 5
4.2 TBUS-4xl Optional Inserts 5
4.3 Power Socket Options 6
4.4 Power Cord Options 8
5 Installing the TBUS-4xl 9
5.1 Assembling the Inner Frame 9
5.2 Installing the Inner Frame 11
5.3 Cutting an Opening in the Table 11
5.4 Inserting the TBUS-4xl through the Cut Out Opening 12
5.5 Connecting the Cables 13
5.6 Inserting the Pass-through Cables 13
5.7 Adjusting the Height of the Inner Frame 14
6 Using the TBUS-4xl 15 7 Technical Specifications of the Assembled TBUS-4xl 16
Figures
Figure 1: TBUS-4xl inside a Table 3 Figure 2: TBUS-4xl Enclosure Top View 4 Figure 3: TBUS-4xl Inner Frame (P/N: 80-003699) 10 Figure 4: Cut out Dimensions 11 Figure 5: Inserting TBUS-4xl into the Prepared Opening 12 Figure 6: TBUS-4xl Boardroom Installation 15
TBUS-4xl - Introduction
1
1
Note that the inner frame, power socket assembly, power cord and other inserts for the TBUS-4xl enclosure are purchased separately.
i

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Our 1,000-plus different models now appear in 11 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers, GROUP 2: Switchers and Matrix Switchers, GROUP 3: Control Systems, GROUP 4: Format/Standards Converters, GROUP 5: Range Extenders and Repeaters, GROUP 6: Specialty AV Products, GROUP 7: Scan Converters and Scalers, GROUP 8: Cables and Connectors, GROUP 9: Room Connectivity, GROUP 10: Accessories and Rack Adapters, and GROUP 11: Sierra Products.
Thank you for purchasing the Kramer TBUS-4xl enclosure, which is ideal for boardrooms, conference and training rooms!
2
TBUS-4xl - Getting Started
Go to www.kramerav.com to check for up-to-date user manuals, a complete list of Kramer wall plates and module connectors, application programs, and to check if firmware upgrades are available (where appropriate).
Inner frame
The inner frame fits into the TBUS enclosure
Universal socket
The Universal socket fits almost all power cords, worldwide
Insert
The insert is fitted in the inner frame. Go to our Web site to check for a variety of single and dual sized inserts
i

2 Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual Use Kramer high-performance high-resolution cables

2.1 Achieving the Best Performance

To achieve the best performance:
Use only good quality connection cables to avoid interference, deterioration
in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
Position your Kramer TBUS-4xl away from moisture, excessive sunlight and
dust

2.2 Glossary

TBUS-4xl - Overview
3
3
Do not place heavy objects on top of the TBUS-4xl.
!

3 Overview

The Kramer TBUS-4xl is a high-quality, anodized aluminum, table-mounted connection bus enclosure for boardrooms and conference rooms. Its attractive enclosure is designed to provide maximum connectivity in the smallest possible footprint. The unit is sturdy, cost-effective, and easy to install.
TBUS-4xl features:
A modular design, letting you tailor the TBUS-4xl according to your
requirements
A black anodized or brushed clear aluminum lid with a special opening for
cable pass-through (note, that other customized colors can also be ordered)
Height adjustment screw holes to set the inner frame (ordered separately) to
the desired height
Power socket openings that are suitable for any of the following power
sockets: for the USA, Germany (the Europlug), Belgium-France, Italy,
Australia, Israel, South Africa or “Universal” for use anywhere (see
compatibility restrictions in Section 7)
Order the power sockets separately from Kramer Electronics
An optional insert kit to replace one power socket
The insert kit can include two wall plate module inserts, two cable pass-through connectors, or one of each
TBUS-4xl is height-adjustable and the cover opens and closes manually, keeping the cables and the connectors out of sight when not used.
Figure 1: TBUS-4xl inside a Table
4
TBUS-4xl - Your TBUS-4xl Enclosure
#
Feature
Function
1
Black Anodized/Brushed Clear Textured Lid
Includes an opening for cable pass-through; covers the Inner Frame, leaving the table surface neat and tidy
2
Outer Rim
Fits over the table surface. A protective rubber guard protects the outer rim during
shipping. Remove it before installing the unit
3
Enclosure
Inserted into the table cut out
4
Table Clamping Set
Rubber Protectors
Protect the table surface when mounting the unit (one for each clamp)
5
Locking Butterfly Screws
Tighten to lock the mounting butterfly screw (one for each clamp)
6
Mounting Butterfly Screws
Tighten to secure the unit to the table surface (one for each clamp)
7
Mounting Brackets
Fit in the bracket slits after inserting the enclosure into the table – to secure the unit to the table surface (one for each clamp)
8
Height Adjustment Screw holes
The screw holes on each side panel are used for adjusting the height of the Inner Frame
9
Bracket Slits
For attaching the two mounting brackets on opposite sides
10
Tie Holes
Insert the self-locking tie through the holes to fix the pass­through cables to the inside walls of the unit

4 Your TBUS-4xl Enclosure

Figure 2: TBUS-4xl Enclosure Top View
TBUS-4xl - Your TBUS-4xl Enclosure
5
5
Inner Frames for TBUS-4xl
Specifications (define what you can include in this inner frame):
T4F-2S (P/N: 80-003599)
2 openings for 2 power sockets 2 RJ-45 connectors 2 USB connectors Two 3.5mm mini jack AUDIO connectors 2 VGA 15-pin HD connectors
T4F-23 (P/N: 80-003699)
2 openings for 2 power sockets 2 blank inserts 1 pass-through insert
Custom made inner frames can be designed if required. Contact Kramer Electronics for more details.
Accessories
Description
Inserts
You can install any wall plate devices as well as any of the single or dual insertssee our Web site for details.
T-2INSERT (P/N: 80-00006699)
The T-2INSERT kit can be installed inside a single power socket opening and includes:
1 single cable pass-through insert 1 dual cable pass-through insert
i

4.1 TBUS-4xl Optional Inner Frames

The following inner frames can be installed in the TBUS-4xl enclosure:

4.2 TBUS-4xl Optional Inserts

6
TBUS-4xl - Your TBUS-4xl Enclosure
Socket Type
Power Specs
Universal:
TS-1U (80-000899)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug.
Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead.
Not compatible with South African plugs.
Socket Type
Power Specs
Socket Type
Power Specs
USA:
TS-1US (80-000999)
100-125V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
TS-1UK (91-000022)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France:
TS-1FR (80-001399)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel:
TS-1IL (80-001799)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU:
TS-1DE (80-001299)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
TS-1ZA (80-001699)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Italy:
TS-1IT (80-001499)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia:
TS-1AU (80-001599)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet

4.3 Power Socket Options

Inner frames support installing one or more of the following power socket assemblies. Note: The Brazilian power sockets are supplied as dual power sockets in a single power socket assembly (see table below).

4.3.1 Single Power Socket Assemblies

TBUS-4xl - Your TBUS-4xl Enclosure
7
7
Socket Type
Power Specs
Socket Type
Power Specs
Switzerland
TS-1CH (80-000027)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil
TS-BR (80-000034)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Socket Type
Power Specs
Universal:
TS-2U (80-001899)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA:
TS-2US (80-001999)
100-125V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France:
TS-2FR (80-002299)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU:
TS-2DE (80-002199)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
TS-2IT (80-002399)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
TS-2CH (80-000026)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
UK
TS-2UK (91-000023)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel:
TS-2IL (80-002699)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet

4.3.2 Dual Power Socket Assemblies

8
TBUS-4xl - Your TBUS-4xl Enclosure
Socket Type
Power Specs
South Africa:
TS-2ZA (80-002599)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Australia:
TS-2AU (80-002499)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Power Cord Type
Description
P/N
6ft/110V (North America)
C-AC/US (110V)
91-000099
6ft/125V (Japan)
C-AC/JP (125V)
91-000699
6ft/220V (Europe)
C-AC/EU (220V)
91-000199
6ft/220V (Israel)
C-AC/IL (220V)
91-000999
6ft/250V (UK)
C-AC/UK (250V)
91-000299
6ft/250V (India)
C-AC/IN (250V)
91-001099
6ft/250V/10A (China)
C-AC/CN (250V)
91-001199
6ft/250V/10A (South Africa)
C-AC/ZA (250V)
91-001299

4.4 Power Cord Options

You can order any of the following power cords to use with a modular TBUS:
TBUS-4xl - Installing the TBUS-4xl
9
9
Each module kit comes with detailed assembly instructions.
i

5 Installing the TBUS-4xl

To install the TBUS-4xl perform the following steps:
1. Assemble the Inner Frame (see Section 5.1).
2. Install the Inner Frame (see Section 5.2).
3. Cut an opening in the table (see Section 5.3).
4. Insert the unit through the opening and secure to the table (see Section 5.4).
5. Connect the cables (see Section 5.5).
6. Insert the pass-through cables (Section 5.6)
7. Adjust the height of the inner frame (see Section 5.7).

5.1 Assembling the Inner Frame

The modules mounted on the inner frame can include single inserts and/or dual inserts as well as a power socket (in some models). This section describes how to assemble these modules.

5.1.1 Mounting the Inserts

You can rearrange or remove any of the plates mounted on the Inner Frame and replace them with Kramer passive wall plates or connector modules for interfacing A/V type signals.
To mount a Kramer insert or connector module:
1. Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate.
2. Place the required Kramer insert over the opening, insert the two screws to fix the Kramer insert in place, and tighten them.
10
TBUS-4xl - Installing the TBUS-4xl
#
Feature
Function
1
Power Socket Opening
Suitable for a single power socket or the optional insert kit for TBUS
2
Blank Plates
Two blank covers that can be replaced with wall plates as required
3
Split Grommets
Push apart slightly to insert cables
4
Split Brackets
Support the split grommet for the pass through-cables
5
Adjustable Height Screw Holes
For adjusting the height of the inner frame
Power socket kits come with assembly instructions.
i
Figure 3: TBUS-4xl Inner Frame (P/N: 80-003699)

5.1.2 Mounting the Power Socket Assemblies

To mount the power socket, place the power socket under the frame in its appropriate place and tighten with the two screws (supplied).
TBUS-4xl - Installing the TBUS-4xl
11
11
Inner Frame kits come with assembly instructions.
The thickness of the table should be 76.2mm / 3 inches or less.
i
i
123+2mm
225+2mm

5.2 Installing the Inner Frame

To install the inner frame:
1. Place the inner frame inside the TBUS-4xl enclosure.
2. Set the required height using your fingers to bring the inner frame to the desired position, screw and tighten it in place using the height adjustment screws (supplied with the inner frame).

5.3 Cutting an Opening in the Table

To cut an opening in the table:
1. Place the included cut out template (that is included with your TBUS-4xl) on the surface of the table exactly where you want to install the TBUS-4xl.
2. Attach the template to the table with the included screws (if using the cut out template).
3. Following the inside edge of the template, cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 (not to scale).
Figure 4: Cut out Dimensions
12
TBUS-4xl - Installing the TBUS-4xl
Kramer Electronics is not responsible for any damage caused to the table.
!
4. Unscrew and remove the template from the surface of the table and clean the table surface. Take care not to damage the table. If needed, you can download a full-scale template from our Web site.

5.4 Inserting the TBUS-4xl through the Cut Out Opening

To install TBUS-4xl in the opening:
1. Remove the protective rubber guard from around the outer rim of the TBUS-4xl housing. Beware of the sharp edge!
2. Carefully insert the unit into the prepared opening (see Figure 5).
3. Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit (see Figure 2, item 7).
4. Verify proper alignment of the unit before tightening the mounting screws.
5. Tighten both mounting butterfly screws upward until they reach the table surface (from underneath). Tighten firmly (see Figure 5).
6. Tighten the locking butterfly screws downward until tight against the mounting bracket.
Figure 5: Inserting TBUS-4xl into the Prepared Opening
TBUS-4xl - Installing the TBUS-4xl
13
13

5.5 Connecting the Cables

When replacing blank inserts with connector inserts (for example, VGA, audio, HDMI and so on):
1. Insert the cables to their appropriate connectors from underneath.
2. Secure the cables to the tie holes using the included self-locking ties. Do not secure the cables too tightly or too loosely. Leave a small amount of slack.
After the TBUS-4xl is connected to mains power and the proper cables, it is ready for use.

5.6 Inserting the Pass-through Cables

To insert the pass-through cables, for example, to connect a laptop, do the following (see Figure 3):
1. Remove the two screws attaching the split pass-through bracket.
2. Remove the split grommet.
3. Insert the cable through the rectangular opening.
4. Open the split grommet slightly and insert the required cables.
5. Place the split bracket around the grommet and position this assembly over the Inner Frame.
6. Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame.
7. Insert the self-locking ties through the tie holes to secure the cables to the inside walls of the enclosure.
14
TBUS-4xl - Installing the TBUS-4xl

5.7 Adjusting the Height of the Inner Frame

If needed, you can adjust the inner frame height to accommodate large or bulky cables. To adjust, perform the following:
1. Remove the four height adjustment screws, while supporting the surface from underneath with your fingers.
2. Raise or lower the inner frame to the required height, insert the screws, and tighten them in place.
TBUS-4xl - Using the TBUS-4xl
15
15

6 Using the TBUS-4xl

Once the TBUS-4xl is installed, you can easily customize it to suit your own requirements by plugging in the required A/V equipment, as illustrated in the example in Figure 6.
Figure 6: TBUS-4xl Boardroom Installation
16
TBUS-4xl - Technical Specifications of the Assembled TBUS-4xl
POWER SOURCE (AC power limits):
Power Socket Assemblies
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug.
Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France (you should order country specific sockets instead).
Not compatible with South African plugs.
USA
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
FUSE RATING:
T 6.3A 250V
OPERATING TEMPERATURE RANGE:
+5 to +45 Deg. Centigrade OPERATING HUMIDITY RANGE:
10 to 90% RHL, non-condensing
STORAGE TEMPERATURE RANGE:
-20 to +70Deg. C. STORAGE HUMIDITY RANGE:
5 to 95% RHL, non-condensing
DIMENSIONS:
Top plate: 243mm x 140.4mm (9.6" x 5.5") W, D Enclosure: 203mm x 102mm x 130mm (8.0" x 4.0" x 5.1") W, D,
H
WEIGHT:
TBUS-4: 0.88kg (1.948lbs) approx. Table clamps: 0.25kg (0.6lbs)
ACCESSORIES:
Power cord, six self-locking ties, template, template screws
OPTIONS:
Inner frames, passive wall plates and interfaces, power socket kits, power cord
Specifications are subject to change without notice at www.kramerav.com
7 Technical Specifications of the Assembled
TBUS-4xl
17
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerav.com E-mail: info@kramerel.com
P/N:
2900-300067
Rev:
3
!
SAFETY WARNING Disconnect the unit from the power supply before opening and servicing
Loading...