TECHNICAL INFORMATION
MS1000 2U STANDARD PROCESSOR
P/N 901-10320000
901-10327902 Iss. 1.0
KONGSBERG MESOTECH LTD. 1598 Kebet Way, Port Coquitlam B.C. Canada V3C 5M5
Tel: (604) 464 8144 Fax: (604) 941 5423
Specifications subject to change without notice
MS1000 SONAR
STANDARD PROCESSOR
P/N 901-10320000
The MS1000 Sonar Processor is a 2U Maritime Rackmount solution for operating scanning sonar heads
through a high speed digital interface. This unit features Intel® processor technology and is designed and
certified to be used in maritime and offshore applications.
The 2U computer is fitted with one Moxa PCIe board that provides a total of four isolated high speed serial
ports for providing the fastest telemetry link speed of 921.6 kbps. The processor comes preconfigured with the
specific version of MS1000 software being purchased with the processor.
TECHNICAL SPECIFICATIONS
Processor: Intel i7 QuadCore 3.1 GHz Processor
RAM: 16 GB
Operating system: Windows 7 64-bit Ultimate
Integrated HD Gaphics (3 ports): Max 2560 x 1600 @ 60 Hz for DVI-I/VGA, DVI-D and DP
(Display Port)
Storage: 1 TB Hard Drive
Integrated Interface Ports: 1 x USB 1.1
2 x USB 2.0
2 x USB 3.0
1 x RS-232
2 x RS-422/RS485
2 x 10/100/1000 Mbps Intel® I217/I210 Gigabit LAN
2 x 10/100/1000 Mbps Realtek 8111E Gigabit LAN
Auxiliary Interface Ports (4 ports): Isolated COM ports (RS-232/422/485)
Digital Telemetry: RS485 for Sonar ports (configured for 921600 kbps)
Power Requirement: 110/220VAC 50/60Hz @ 150W max
Temperature Range: -15 to +55°C operating
-20 to +60°C storage
Material: Heavy-duty steel
Dimensions: Height: 3.46” / 88 mm
Width: 16.93” / 430 mm
Depth: 18.15” / 461 mm
Weight: 22.0 lb/10 kg
Certification: IEC 60945, IACS E10, EN61162, EU RO MR
OUTLINE DRAWINGS
Specications subject to change without any further notice.
Images courtesy of Hatteland Display AS.
www.kongsbergmesotech.com
E-mail: km.sales.vancouver@kongsberg.com
Telephone: +1 604 464 8144
Toll-free: +1 888 464 1598
DIMENSIONS ARE IN MM [INCHES]
901-10327901-1.2
© 2015 - Kongsberg Mesotech Ltd.
Document revisions
Version
Date Written by Checked by Approved by
About this document
The information contained in this document is subject to change without prior notice.
Kongsberg Mesotech Ltd. shall not be liable for errors contained herein, or for incidental or
consequential damages in connection with the furnishing, performance, or use of this
document.
© 2015 Kongsberg Mesotech Ltd. All rights reserved. No part of this work covered by the
copyright hereon may be reproduced or otherwise copied without prior permission from
Kongsberg Mesotech Ltd.
2 901-10327904-1.0
MS1000 Sonar Processor – Product Information
Table of contents
1 INTRODUCTION .................................................................................................... 5
2 TYPICAL SYSTEM DIAGRAM ........................................................................... 6
3 PROCESSOR OVERVIEW .................................................................................... 7
4 INSTALLATION DETAILS ................................................................................... 9
4.1 Cable Adapter for the 4-Port Serial Card ............................................................ 9
5 MS1000 SONAR SYSTEM WIRING .................................................................. 10
5.1 Serial Card pinout ............................................................................................. 10
5.2 Sonar Head electrical connections .................................................................... 13
6 MS1000 SOFTWARE INSTALLATION ............................................................ 14
6.1 REMOVE OLD INSTALLATION .................................................................. 14
6.2 INSTALL NEW SOFTWARE ......................................................................... 14
6.2.1 Installing the MS1000 software ...................................................................... 14
6.2.2 Set the host sonar applications with Admin rights ......................................... 15
6.2.3 Configure Dual Serial Ports if necessary ........................................................ 16
6.2.4 Set the sonar application to Autostart ............................................................. 18
6.2.5 Disable User Account Control (UAC) ........................................................... 18
6.2.6 Verify Autostart operation .............................................................................. 19
6.2.7 Enable serial ports .......................................................................................... 19
901-10327904-1.0 3
© 2015 - Kongsberg Mesotech Ltd.
This page in tentionally left blank
4 901-10327904-1.0