Kongsberg ACS500 Instruction Manual

INSTRUCTION MANUAL
ACS500
Acoustic Control System, Gisma testport system
KongsbergACS500
AcousticControlSystem
InstructionManual,Gismatestport
system
July2016
©
KongsbergMaritimeAS
Revisionstatus
Documentnumber:397128/RevisionC
Rev.C
July2016
UpdatedmanualwithaprocedureabouthowtoreplaceanSCUwitha spareSCU.
Copyright
©2016KongsbergMaritimeAS TheinformationcontainedinthisdocumentremainsthesolepropertyofKongsbergMaritimeAS.Nopart ofthisdocumentmaybecopiedorreproducedinanyformorbyanymeans,andtheinformationcontained withinitisnottobecommunicatedtoathirdparty,withoutthepriorwrittenconsentofKongsberg MaritimeAS.Thedocument,oranypartofit,maynotbetranslatedtoanyotherlanguagewithoutthe writtenapprovalfromKongsbergMaritimeAS.
Disclaimer
KongsbergMaritimeASendeavourstoensurethatallinformationinthisdocumentiscorrectandfairly stated,butdoesnotacceptliabilityforanyerrorsoromissions.
Warning
Theequipmenttowhichthismanualappliesmustonlybeusedforthepurposeforwhichitwas designed.Improperuseormaintenancemaycausedamagetotheequipmentand/orinjury topersonnel.Allusersmustbefamiliarwiththecontentsoftheappropriatemanualsbefore attemptingtoinstall,operate,maintainorinanyotherwayworkontheequipment. KongsbergMaritimeASdisclaimsanyresponsibilityfordamageorinjurycausedbyimproper installation,useormaintenanceoftheequipment.
KongsbergMaritimeAS
www.kongsberg.com
InstructionManual,Gismatestportsystem
Tableofcontents
ABOUTTHISMANUAL.......................................................9
ACS500...........................................................................10
Systemdescription.................................................................................................11
Systemdiagram......................................................................................................12
Systemunits...........................................................................................................14
AcousticCommandUnit.............................................................................14
Dunkingtransducerunit..............................................................................14
Subseatransducer.......................................................................................15
SubseaControlUnit....................................................................................15
Fieldsimulator...........................................................................................15
Listofparts.............................................................................................................16
Generalsupplyconditions......................................................................................16
Receipt,unpackingandstorage....................................................................16
Equipmentresponsibility.............................................................................16
Supportinformation...............................................................................................17
PLANNINGTHEACS500INSTALLATION..........................18
Installationdrawings..............................................................................................19
INSTALLINGTHESUBSEACONTROLUNIT......................20
InstallingtheSubseaControlUnit.........................................................................20
INSTALLINGTHESUBSEATRANSDUCER.........................21
Installingthesubseatransducer..............................................................................21
CABLELAYOUTANDINTERCONNECTIONS......................23
Cableplan...............................................................................................................24
Listofcables..........................................................................................................26
Cableprocedures....................................................................................................27
ConnectingthecablefromtheSubseaControlUnittotheexternalquad
batteryunit(option)....................................................................................28
ConnectingthetransducercablefromtheSubseaControlUnittothesubsea
transducer...................................................................................................28
Connectingthey-splitcablefromtheSubseaControlUnittothevalve
package......................................................................................................29
ConnectingtheinterfacecablefromtheSubseaControlUnittothevalve
package......................................................................................................29
GETTINGSTARTED..........................................................30
Dunkingtransducerwithcabledrum.....................................................................30
Openingthecabledrum..............................................................................30
Closingthecabledrum................................................................................31
Startingoperation...................................................................................................31
397128/C
3
KongsbergACS500
PoweringontheACS500............................................................................31
PoweringofftheACS500............................................................................32
Startingupthesurfacesystem......................................................................32
Valveoperation...........................................................................................33
ACOUSTICCOMMANDUNIT.............................................34
ACUComputerbuttons..........................................................................................37
Changingthebrightnessandcomputerexit...................................................37
Powerbuttonandbatterylevel.....................................................................37
Trackball....................................................................................................37
Userinterface.........................................................................................................38
Menubar....................................................................................................39
SystemStatus.............................................................................................40
Batterystatus..............................................................................................40
SensorInput...............................................................................................41
MoreStatus................................................................................................41
Help...........................................................................................................42
SubseaTelemetryPower.............................................................................42
Execute......................................................................................................42
SCUSolenoidInformation..........................................................................42
Exit............................................................................................................42
OPERATIONALPROCEDURES..........................................43
Valveoperation.......................................................................................................43
Batterylevel...........................................................................................................45
Batterystatus,AcousticCommandUnit.......................................................45
Batterystatus,SubseaControlUnit..............................................................45
Externalbatterycapacity.............................................................................45
Usersettings...........................................................................................................46
SettingthetelemetrypowerlevelfortheACU..............................................46
SettingthetelemetrypowerlevelfortheSubseaControlUnit........................47
ChangingbetweenCymbalandFSK............................................................47
Systemstatus..........................................................................................................48
CheckingcommunicationbetweentheAcousticCommandUnitandthe
SubseaControlUnit....................................................................................48
Readingthesystemstatusinformation..........................................................48
Readingthesensorinput.............................................................................49
Readingthesoftwareversions.....................................................................49
Emergencysequence..............................................................................................50
OperatingACS500fromHiPAP(optional)............................................................50
AutoShutdown(option).........................................................................................51
Valvesusedinthesequence.........................................................................52
Sequenceoperationandtiming....................................................................52
Enabling/DisablingAutoShutdown.............................................................52
4
397128/C
InstructionManual,Gismatestportsystem
Messages................................................................................................................54
NoresponsefromSCU...............................................................................54
Linkstatus..................................................................................................54
Systemstatus..............................................................................................55
BOPstatus.................................................................................................56
Batterystatus..............................................................................................57
Sensorinput...............................................................................................57
Morestatus.................................................................................................58
Valveoperationmessages............................................................................58
Case1;ThevalvepackageisnotinArmmode.............................................62
Case2;Tryingtoactivateavalvefunctiontwice...........................................64
Case3;Gettingnostatusreplyafterexecutionofavalve..............................65
Case4;TryingtoactivatetheArmfunctiontwice.........................................66
Case5;ExecutingaDisarmfunctionwhenavalvefunctionisstill
active.........................................................................................................66
SIMULATIONANDTEST..................................................68
Connectingthetestequipment...............................................................................70
Alternative1...............................................................................................70
Alternative2(preferredmethod)..................................................................70
Testprocedure........................................................................................................70
TestingACS500withHiPAP.................................................................................72
MAINTENANCE................................................................74
AcousticCommandUnit........................................................................................75
CleaningtheAcousticCommandUnit..........................................................75
ChargingtheAcousticCommandUnit.........................................................75
ChangingthebatteryontheAcousticCommandUnit...................................76
Dunkingtransducer................................................................................................77
Cleaningthedunkingtransducer..................................................................77
Checkingthedunkingtransducer.................................................................77
SubseaControlUnit...............................................................................................78
SCUmaintenanceoverview.........................................................................78
CleaningtheSubseaControlUnit................................................................78
OpeningtheSubseaControlUnit.................................................................78
ReplaceaSubseaControlUnitandduplicatetheconguration......................79
ChangingthebatteryontheSubseaControlUnit.........................................80
TestingthesealsontheSubseaControlUnit................................................82
ExternalquadbatteryunitfortheSubseaControlUnit.........................................83
Quadbatterymaintenanceoverview.............................................................84
Cleaningtheexternalquadbatteryunit.........................................................84
Openingtheexternalquadbatteryunit.........................................................84
Changingthebatteriesintheexternalquadbatteryunit.................................85
Subseatransducer...................................................................................................86
397128/C
5
KongsbergACS500
Cleaningthesubseatransducer....................................................................86
Replacingthesubseatransducer...................................................................86
Intersealtest............................................................................................................88
Assemblethetestkit...................................................................................88
Testingtheseal...........................................................................................89
ChangingthebatteryintheDigitalpressureindicator....................................90
ILLUSTRATEDSPAREPARTSCATALOGUE.......................92
Linereplaceableunits.............................................................................................93
Orderingspareparts...............................................................................................94
AcousticCommandUnitspareparts......................................................................94
AcousticCommandUnitlinereplaceableunits.............................................94
AcousticCommandUnit,completeunit.......................................................95
AcousticCommandUnit,battery.................................................................95
Dunkingtransducerspareparts..............................................................................95
Dunkingtransducerlinereplaceableunits.....................................................95
Dunkingtransducer,completeunit...............................................................95
SubseaControlUnitspareparts.............................................................................96
SubseaControlUnitlinereplaceableunits....................................................96
SubseaControlUnit,completeunit..............................................................97
SubseaControlUnit,battery........................................................................97
SubseaControlUnit,topendcap.................................................................97
SubseaControlUnit,ventscrewfortopendcap...........................................97
SubseaControlUnit,maintenancekitfortopendcap....................................98
SubseaControlUnit,bracket.......................................................................98
SubseaControlUnit,y-splitcable................................................................98
SubseaControlUnit,interfacecable.............................................................99
SubseaControlUnit,seriallinecable...........................................................99
SubseaControlUnit,sealingcapfor7-pinsconnector...................................99
SubseaControlUnit,externalquadbatteryunit............................................99
SubseaControlUnit,cabletotheexternalquadbatteryunit...........................99
Subseatransducerspareparts...............................................................................100
Subseatransducerlinereplaceableunits.....................................................100
Subseatransducer,completeunit...............................................................100
Subseatransducer,transducercable............................................................100
Testequipmentspareparts...................................................................................100
Testequipmentlinereplaceableunits.........................................................100
Simulator.................................................................................................101
Simulatortestcable...................................................................................101
PatchcablefortestingwithHiPAP.............................................................101
Transducertestcable.................................................................................101
Intersealtestkit........................................................................................101
EQUIPMENTHANDLING................................................102
6
397128/C
InstructionManual,Gismatestportsystem
Disposal................................................................................................................103
Inspection.............................................................................................................103
Lifting...................................................................................................................103
Re-packaging........................................................................................................104
Storageafterunpacking........................................................................................104
Storageafteruse...................................................................................................105
Cleaningcabinets......................................................................................105
Mechanicalunits.......................................................................................105
Cables......................................................................................................106
Dehumidier............................................................................................106
Coatings...................................................................................................106
Storagepriortoinstallationoruse.......................................................................106
Unpacking............................................................................................................107
Generalunpackingprocedure....................................................................107
Unpackingelectronicandelectromechanicalunits......................................108
Unpackingmechanicalunits......................................................................108
Transportation.......................................................................................................109
DRAWINGFILE.............................................................110
Dunkingtransducerunit,outlinedimensions.......................................................111
AcousticCommandUnit,outlinedimensions......................................................112
SubseaControlUnit,outlinedimensions.............................................................113
SubseaControlUnit,arrangement.......................................................................114
SubseaControlUnit,bracket................................................................................115
TDR30V34GTSubseatransducer,outlinedimensions.......................................116
ExternalquadbatteryunitforSCU,outlinedimensions......................................117
Simulator,outlinedimensions..............................................................................118
O-ringinformationfortestports..........................................................................119
TECHNICALSPECIFICATIONS.......................................120
Acousticlink.........................................................................................................121
Performancespecications...................................................................................122
Weightsandoutlinedimensions...........................................................................123
Powerspecications.............................................................................................123
Environmentalspecications...............................................................................124
LITHIUMBATTERIESSAFETYPROCEDURES..................125
Identicationoftheproductsandcompany.........................................................125
Productname............................................................................................125
Rangeofproducts.....................................................................................125
Companyaddress......................................................................................126
Compositionandinformationonchemicals.........................................................126
Batterychemicals.....................................................................................126
397128/C
7
KongsbergACS500
Batteryweightandlithiumcontent.............................................................126
Batterycellmanufacturers/types................................................................127
Batterydesign...........................................................................................127
Hazardsidentication...........................................................................................127
Dangerofexplosions................................................................................128
Noxiousgases...........................................................................................128
First-aidmeasures.................................................................................................128
Fire-ghtingmeasures..........................................................................................129
Handlingandstorage............................................................................................129
Recoveringafunctioningtransponder........................................................129
Recoveringafailingtransponder................................................................130
Handlingaheatedorself-heatedtransponder..............................................130
Handlingatransponderifreliefvalveopens...............................................130
Openingatransponderwithdefect/possibledefectbattery...........................131
Openingafunctioningtransponder.............................................................131
Handlingheatedorwarmseparatebattery..................................................131
Handlingtranspondersandseparatetransponderbatteriesincaseofan
externalre..............................................................................................132
Storage.....................................................................................................132
Exposurecontrolsandpersonalprotection..........................................................132
Physicalandchemicalproperties.........................................................................133
Stabilityandreactivity..........................................................................................133
Toxicologicalinformation....................................................................................133
Ecologicalinformation.........................................................................................133
Disposalconsiderations........................................................................................134
Transportinformation...........................................................................................134
Regulatoryinformation........................................................................................134
Otherinformation.................................................................................................135
ATYPEAPPROVALCERTIFICATE......................................136
BINFORMATIONFROMTHECONNECTORPRODUCER.......141
8
397128/C
Aboutthismanual
Purpose
Thepurposeofthisinstructionmanualistoprovidethedescriptionsandprocedures requiredtoallowforsafeandefcientinstallationanduseoftheKongsbergACS500.

Aboutthismanual

Targetaudience
ThismanualisintendedforallusersofKongsbergACS500.
Registeredtrademarks
Windows
®
,WindowsXP
®
,andWindows
®
7areeitherregisteredtrademarks,or
trademarksofMicrosoftCorporationintheUnitedStatesand/orothercountries. HIPAP
®
isaregisteredtrademarkofKongsbergMaritimeASinNorwayandother
countries.
WARNING
SubseaControlUnitbatteries:
Changebatterieswithlessresidualcapacitythan25%,batteries olderthan10years,batteriesusedformorethan1year,and batterieswithunknownstatus.
397128/C
9
KongsbergACS500
StudythischaptertofamiliarizeyourselfwiththeKongsbergACS500.
Topics
Systemdescriptiononpage11
Systemdiagramonpage12
Systemunitsonpage14

ACS500

Listofpartsonpage16
Generalsupplyconditionsonpage16
Supportinformationonpage17
10
397128/C

Systemdescription

ACS500isdesignedforoptimalcontrolofsubseavalvesandisratedto4000metredepth. ACS500maybeusedtocontrolanblowoutpreventersystemasanemergencysystem
orothersubseavalvecontrolfunctions.
ACS500
397128/C
11
KongsbergACS500

Systemdiagram

AstandardACS500systemdiagramisprovided.
Systemwithy-splitcable
12
397128/C
Systemwithinterfacecables
ACS500
397128/C
13
KongsbergACS500

Systemunits

TheKongsbergACS500comprisesthefollowingmainunits.
Topics
AcousticCommandUnitonpage14
Dunkingtransducerunitonpage14
SubseaControlUnitonpage15
Subseatransduceronpage15
Fieldsimulatoronpage15

AcousticCommandUnit

TheACUisthemainsysteminteractionunit. TheACUcomprisesacomputerandatouchscreen
inasplashproofportablecase. TheACUhasaninternalrechargeablebatterywith
approximately10hoursofcontinuousoperationona fullychargedbattery.
ThecustomeralsohavetheoptionofusingtheACU asanemergencysystemifthecomputerisdown.A predenedvalvesequencemaybeexecutedusinga twohand,twobuttonoperation.

Dunkingtransducerunit

Thetransducerwillconvertelectricenergyinto pressurewavesinthewater.Thecharacteristicsof thesepressurewaves-power,frequencyandshape
-aredeterminedbytheelectricsignalappliedtothe transducer.
14
397128/C

Subseatransducer

Thetransducerwillconvertelectricenergyintopressure wavesinthewater.Thecharacteristicsofthesepressure waves-power,frequencyandshape-aredeterminedbythe electricsignalappliedtothetransducer.

SubseaControlUnit

TheSCUistheunitcontrollingthe subseavalves.
ACS500
CommandsaresentfromtheACU viathetransducersandsentfromthe SCUtothevalves.

Fieldsimulator

Thesimulatorisusedforsimulatingthevalves whentheSCUisatthesurface,tocheckthesystem functionality.
ThesimulatorisconnectedtotheSCUwithatestcable.
397128/C
15
KongsbergACS500

Listofparts

Important
SeeScopeofdeliveryintheregistrationformfortheunitsinyoursystem.

Generalsupplyconditions

ThefollowinggeneralsupplyconditionsapplytothisKongsbergACS500delivery.
Topics
Equipmentresponsibilityonpage16
Receipt,unpackingandstorageonpage16

Receipt,unpackingandstorage

Uponacceptingshipmentoftheequipment,theshipyardand/orthedealershouldensure thatthedeliveryiscompleteandinspecteachshippingcontainerforevidenceofphysical damage.Ifthisinspectionrevealsanyindicationofcrushing,dropping,immersionin wateroranyotherformofdamage,therecipientshouldrequestthatarepresentative fromthecompanyusedtotransporttheequipmentbepresentduringunpacking.
Allequipmentmustbeinspectedforphysicaldamage,i.e.brokencontrolsandindicators, dents,scratchesetc.duringunpacking.Ifanydamagetotheequipmentisdiscovered,the recipientshouldnotifyboththetransportationcompanyandKongsbergMaritimesothat KongsbergMaritimecanarrangeforreplacementorrepairofthedamagedequipment.
Onceunpacked,theequipmentmustbestoredinacontrolledenvironmentwithan atmospherefreeofcorrosiveagents,excessivehumidityortemperatureextremes.The equipmentmustbecoveredtoprotectitfromdustandotherformsofcontamination whenstored.
Formoreinformation,seetheinformationrelatedtoequipmenthandling.
Relatedtopics
Equipmenthandlingonpage102

Equipmentresponsibility

Theshipyardperformingtheinstallationand/orequipmentthedealerbecomesfully responsiblefortheequipmentuponreceiptunlessotherwisestatedinthecontract.
16
397128/C
Thedurationofresponsibilityincludes:
•Theperiodoftimetheequipmentisstoredlocallybeforeinstallation.
•Duringtheentireinstallationprocess.
•Whilecommissioningtheequipment.
•Theperiodoftimebetweencommissioningandthenalacceptanceoftheequipment bytheenduser(normallytheownerofthevesseltheequipmenthasbeeninstalled onto).
Unlessotherarrangementshavebeenmadeinthecontract,theKongsbergACS500 guaranteeperiod(asspeciedinthecontract)beginswhentheacceptancedocuments havebeensigned.

Supportinformation

ACS500
IfyouneedtechnicalsupportontheACS500youmustcontactKongsbergMaritime.
Address:Strandpromenaden50,3190Horten,Norway
Telephone,24h:+4733032407
Telefax:+4733047619
E-mailaddress:km.support@kongsberg.com
Website:http://www.km.kongsberg.com
Supportwebsite:http://www.km.kongsberg.com/support_hpr
397128/C
17
KongsbergACS500
PlanningtheACS500
installation
ThischapterprovidestheinformationnecessarytoplantheinstallationoftheKongsberg ACS500accordingtoKongsbergMaritime’srequirements.
Correctinstallationisvitaltothesystemperformance. Seeyourregistrationformforallpartsofyoursystemincludingcables.
Topics
Installationdrawingsonpage19
18
397128/C
PlanningtheACS500installation

Installationdrawings

Allinstallationdrawingsmustbesuppliedbytheshipyardperformingtheinstallation.
Note
Theinstallationshipyardmustprovideallnecessaryinstallationdrawings,andif required,thesemustbeapprovedbytheapplicableauthorities.
Note
Theinstallationmustbeapprovedbythevessel’ snationalregistryandcorresponding maritimeauthorityand/orclassicationsociety.Theshipownerandshipyardperforming theinstallationareresponsibleforobtainingandpayingforinstallationapproval.
KongsbergMaritimeoffersfreeadviceforinstallationplanning.Proposedarrangements maybesentforcommentaryorsuggestionssuppliedbyKongsbergMaritime.The followingdrawingsshouldbesubmittedshouldassistanceberequested:
•Generalarrangement
•Bodyplananddrawingsoftherelevantcompartment
•Linesplan
Relatedtopics
Drawingleonpage110
397128/C
19
KongsbergACS500
InstallingtheSubsea
ControlUnit
ThischapterexplainshowtoinstalltheSCU.
Note
Theinstallationshipyardmustprovideallnecessaryinstallationdrawings,andif required,thesemustbeapprovedbytheapplicableauthorities.

InstallingtheSubseaControlUnit

Purpose
ThisprocedureexplainshowtoinstalltheSCU.
Procedure
1TheSCUcomessecuredonamountingbracket.
•SeetheDrawingleonpage110. MountthebracketontothevalvecontrolstructurebythehooksbehindtheSCUs. Thebracketisconstructedtoholdtheunitsinanuprightposition.
2SecuretheSCUwithfourM12boltswithnutsandspringwashers.
Note
Theseboltsarenotprovidedasthetypesandlengthswilldependonthethickness andmaterialofthevalvecontrolstructure.
3Tightentheboltstothetorquerecommendedbytheboltmanufacturer.
20
397128/C

Installingthesubseatransducer

Installingthesubsea
transducer
ThischapterexplainshowtoinstalltheACS500transducer.
Note
Theinstallationshipyardmustprovideallnecessaryinstallationdrawings,andif required,thesemustbeapprovedbytheapplicableauthorities.

Installingthesubseatransducer

Purpose
Thisprocedureexplainshowtoinstallthesubseatransducer.
Procedure
1Thetwotransducersmustbemountedonthevalveframework.Thetransducers
mustbelocatedatoppositesidesofthevalvepackage,andmustbepositionedsuch thattheyhaveaclearlineofsighttothesurface.Theyshouldbelocatedasfar awayfromthevalvestructureandotherreectivesurfacesaspossibletoreducethe effectsofacousticshadowingandechoes.
Note
Thesubseatransducershouldbepositionedminimum2.5metresfromthevalve structure.
2Preparethelocationandthenecessarytools.
•SeetheDrawingleonpage110andyourtransducerforlocationoftheholes.
3SecurethetransducerwithsixM6bolts,nutsandspringwashers.
Note
Theseboltsarenotprovidedasthetypesandlengthswilldependonthethickness andmaterialofthemountingstructure.
397128/C
21
KongsbergACS500
4Tightentheboltstothetorquerecommendedbytheboltmanufacturer.
IfA4orsimilarboltsareused,tightentheboltstoatorqueof40Nm.
22
397128/C

Cablelayoutandinterconnections

Cablelayoutand
interconnections
Thischapterprovidesthecableplanandcableinstallationrequirementsforthe KongsbergACS500.
Topics
Cableplanonpage24
Listofcablesonpage26
Cableproceduresonpage27
397128/C
23
KongsbergACS500

Cableplan

ObservethecableplanforKongsbergACS500.AllcablesareprovidedfromKongsberg Maritime.
Systemwithy-splitcable
24
397128/C
Systemwithinterfacecables
Cablelayoutandinterconnections
ADunkingtransducerwithcabledrum
BAcousticCommandUnit
CSubseaControlUnit
DSubseaTransducer
ECustomervalvepackage
FQuadbatterypack
GFieldsimulator
397128/C
25
KongsbergACS500

Listofcables

ObservethelistofcablesfortheKongsbergACS500.TheCxnumbersrefertothe cableplan.Referencesaremadetotheindividualcabledrawingsspecifyingeachcable withitsconnectors.
Seescopeofdeliveryintheregistrationformforthespeciccablesinyoursystem. C1Dunkingtransducercable
ThiscableprovidesthesignalstoandfromtheAcousticCommandUnit. Thecableisonacabledrum,is70metreslongandpartofthedunkingtransducer
unit.
C2Subseatransducercable
ThiscableprovidesthesignalstoandfromtheSubseaControlUnitandis15 metreslong.
C3Subseatransducercable
ThiscableisidenticaltoC2.
C4Subseabatterycable(optional)
ThiscableisconnectingtheexternalbatterytotheSubseaControlUnitandis2 metreslong.
C5Subseabatterycable(optional)
ThiscableisidenticaltoC4.
C6Transducertestcable
Thiscableisfortestinginair,is50metreslongandonacabledrum.
C7Fieldsimulatortestcable
Thiscableisforsimulationandtestingandiscustomerspecic.
C8ChargingcablefortheAcousticCommandUnit. C9PatchcablefortestingwithHiPAP .
ThiscableisfortestingwiththeHiPAPsystem.
C10Y-splitPBOFcable;onlyforsystemswithy-splitcable.
Thisy-splitcableconnectsbothSubseaControlUnitstothecustomervalve package.Thiscableiscustomerspecic.
C11Interfacecable;onlyforsystemswithinterfacecables.
ThiscableconnectstheSubseaControlUnittothecustomervalvepackage. Thiscableiscustomerspecic.
C12Interfacecable;onlyforsystemswithinterfacecables.
ThiscableconnectstheSubseaControlUnittothecustomervalvepackage. Thiscableiscustomerspecic.
26
397128/C
Cablelayoutandinterconnections

Cableprocedures

ObservethefollowingprocedurestodotheACS500cabling.
1AllcablesareprovidedbyKongsbergMaritime. 2Inordertoeaseaccessformaintenancepurposes,andtoallowforvibration,make
surethatsomeslackisprovidedforeachcable.
Topics
ConnectingthecablefromtheSubseaControlUnittotheexternalquadbattery unit(option)onpage28
ConnectingthetransducercablefromtheSubseaControlUnittothesubsea transduceronpage28
Connectingthey-splitcablefromtheSubseaControlUnittothevalvepackageon page29
397128/C
27
KongsbergACS500

ConnectingthecablefromtheSubseaControlUnittothe externalquadbatteryunit(option)

Purpose
Thiscableprovidespowerfrom theexternalbatteriestotheSCU.
Procedure
1Thesystemmustbeturned
offbeforeconnectingthe externalquadbatteries. MakesuretheACUis switchedoffandthelidsare offtheSCUs.
2Securethecableonthestructureforthevalvepackagesothattheydonotpresenta
hazardtoROVsetc.Makesurethereisslackformovingparts.
3Mountanyprotectivecoversnecessarytopreventthecablesbeingdamaged. 4ConnectthecabletotheSCUasindicated.Connecttheotherendtotheexternal
batteryunit. ThesearecablesACS500/C4andACS500/C5.

ConnectingthetransducercablefromtheSubseaControl Unittothesubseatransducer

Purpose
Thiscableprovidesthesignalsfromthetransducertothe SCUandback.
Procedure
1Securethecableonthestructureforthevalvepackage
sothattheydonotpresentahazardtoROVsetc.Make surethereisslackformovingparts.
2Mountanyprotectivecoversnecessarytopreventthe
cablesbeingdamaged.
3ConnectthecabletotheSCUasindicated. 4Connecttheotherendtothesubseatransducer.
ThesearecablesACS500/C2andACS500/C3.
28
397128/C
Loading...