For more information on other great EdgeStar products on the web, go to http://www.edgestar.com
Important Safety Information
Improper handling can cause serious damage to the appliance and/or to the
user. Please read the following safety information.
Electrical Safety
This unit is designed for indoor use only.
Do not use the unit in extremely humid or wet environments.
Do not spray water and wet the housing or control panel.
Do not pull the unit by the cord.
Always turn the unit off and unplug it from the outlet when cleaning.
Unplug the unit if it is not going to be used for a long period of time.
Do not operate the unit with a damaged plug or a loose socket.
Use only the correct power supply with appropriate amperage.
If the power cord is damaged, it must be replaced by the manufacturer,
a service agent, or qualified technician.
Do not remove any part of the casing unless instructed by an
authorized technician.
General Safety
This portable air conditioner is not intended to be used by children.
Children should be supervised to ensure that they do not play with this
product.
Do not allow children to play with the controls or drop any objects into
the air outlets or vents.
Do not place objects or let any person sit on top of the unit.
Only use in the upright position on a flat, level surface and provide at
least 20 inches of clearance from any walls or objects.
Route the power cord carefully to avoid a tripping hazard.
This unit is intended for domestic use only. Do not use the portable air
conditioner for industrial or commercial use. Any other use may
invalidate the warranty.
Your portable air conditioner is supplied with a Leakage-Current
RESET
TEST
DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS.
Press the RESET button to start using your air conditioner.
Do not use the TEST and RESET buttons as an ON/OFF switch.
Electrical products should not be disposed of with household waste.
Please contact your local recycling center for more information on how
to recycle electronic waste.
Detection and Interruption (LCDI) safety plug. This device provides
protection to reduce the risk of fire due to arcing faults in the power
supply cord. Before using your portable air conditioner, follow the
instructions below to ensure that the LCDI plug is working properly:
1. Plug the power cord to a grounded outlet.
2. Press the TEST button on the LCDI plug. This should trip the
plug and cut the power to the air conditioner. If the plug does not
trip and you are able to turn on the unit, please contact EdgeStar
support.
i
Table of Contents
IMPORTANT SAFETY INFORMATION ................................................................. I
Thank you for purchasing this EdgeStar portable air conditioner. We are glad you
chose us. We believe that your purchase of this product opens a relationship
between you and EdgeStar. We will provide the customer support needed to
nurture that relationship.
This manual contains important information regarding the proper installation, use
and maintenance of your portable air conditioner. Following this manual will
ensure that your product will work at its peak performance and efficiency.
Please save the original product packaging in case you need to safely transport
your portable air conditioner.
For Your Records:
Please write down the model number and serial number
below for future reference. Both numbers are located on the
ratings label on the back of your unit and are needed to
obtain warranty service. You may also want to staple your
receipt to this manual as it is the proof of your purchase, and
is also needed for service under your warranty.
Model Number:
Serial Number:
Date of Purchase:
To better serve you, please do the following before contacting customer service:
If you received a damaged product, immediately contact the dealer that
sold you the product.
Read and follow this instruction manual carefully to help you install, use
and maintain your portable air conditioner.
Read the troubleshooting section of this manual as it will help you
diagnose and solve common issues.
Visit us on the web at http://www.edgestar.com to register your
product, download product guides, additional troubleshooting resource s
and up-to-date information.
If you need warranty service, our friendly customer service
representatives are available via email at service@edgestar.com or by
telephone at 1 (866) 319-5473.
1
Front View
Front Air Vent
Notes: You must open the
front air vent when
operating the unit. The
unit is designed to blow
air mostly from the right
side.
Parts Identification
Handle
Front Control Panel
Front Grille / Air Intake
Back View
Exhaust
Power Cord
Drain
Caster
KoldFront Portable Air Conditioner 2
CAUTION: Never operate
the air conditioner without
the pre-filter attached.
Carbon Filter
Front Grille
Installing the Carbon Filter
Your portable air conditioner ships with a pre-filter and an activated
carbon filter. The carbon filter will help remove contaminates and
odors from the air. It is recommended you replace the carbon filter
every two to three months, or as needed. It is necessary to clean
the pre-filter periodically. Follow the steps below to install the
carbon filter:
1. Shut off the unit if it is on. Pull the front grille forward.
2. Place the carbon filter between the grille and the pre-filter.
3. Close the grille.
Pre-filter
Pre-filter
3
Preparations for installing
the window kit
NOTE: Exhaust Covers
may be attached to the
Grated Adapters. You
may need to twist and pull
apart to separate them.
NOTE: You may need to
contact your electrician if
your room’s circuit is not
able to power your unit.
Window Kit Installation Instructions
You must vent your portable air conditioner when running in it
cooling mode. Your unit includes a window exhaust kit that can be
used to vent the unit out a window.
Before you begin, make sure you have all the parts necessary for
installation.
Window Kit Parts List:
If you have multiple windows, choose one that is near an electrical
outlet that will be able to provide sufficient power to your unit. See
the power requirements listed on the product label printed on the
side, or on the back of your portable air conditioner.
Your window kit can be installed on a horizontal or vertical sliding
window as shown in the following pictures:
4 Screws
1 Exhaust Hose
2 Duct Connectors
1 Grated Adapter
1 Exhaust Cover
1 Window Kit Plate with Hole
1 Window Kit Plate
Follow the instructions on the next pages to install the window kit.
KoldFront Portable Air Conditioner 4
Installing the grated adapter
1. Insert the round grated adapter through the back
grooved side of the window kit plate with hole.
2. Secure the grated adapter by fastening the screws from
flat side of the window kit plate to the holes on the grated
adapter.
5
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.