Important Safety Information
Improper handling can cause serious damage to the appliance and/or to the
user. Please read the following safety information.
Electrical Safety
x This unit is designed for indoor use only.
x Do not use the unit in extremely humid or wet environments.
x Do not spray water and wet the housing or control panel.
x Do not pull the unit by the cord.
x Always turn the unit off and unplug it from the outlet when cleaning.
x Unplug the unit if it is not going to be used for a long period of time.
x Do not operate the unit with a damaged plug or a loose socket.
x Use only the correct power supply with appropriate amperage.
x If the power cord is damaged, it must be replaced by the manufacturer,
a service agent, or qualified technician.
xDo not remove any part of the casing unless instructed by an
authorized technician.
General Safety
x This portable air conditioner is not intended to be used by children.
x Children should be supervised to ensure that they do not play with this
product.
xDo not allow children to play with the controls or drop any objects into
the air outlets or vents.
x Do not place objects or let any person sit on top of the unit.
x Only use in the upright position on a flat, level surface and provide at
least 20 inches of clearance from any walls or objects.
x Route the power cord carefully to avoid a tripping hazard.
x This unit is intended for domestic use only. Do not use the portable air
conditioner for industrial or commercial use. Any other use may
invalidate the warranty.
Your portable air conditioner is supplied with a Leakage-Current
Detection and Interruption (LCDI) safety plug. This device provides
RESET
TEST
protection to reduce the risk of fire due to arcing faults in the power
supply cord. Before using your portable air conditioner, follow the
instructions below to ensure that the LCDI plug is working properly:
1. Plug the power cord to a grounded outlet.
2. Press the TEST button on the LCDI plug. This should trip the
plug and cut the power to the air conditioner. If the plug does not
trip and you are able to turn on the unit, please contact technical
support.
DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS.
Press the RESET button to start using your air conditioner.
Do not use the TEST and RESET buttons as an ON/OFF switch.
Electrical products should not be disposed of with household waste.
Please contact your local recycling center for more information on how
to recycle electronic waste.
Koldfront Portable Air Conditioner ii
Table of Contents
IMPORTANT SAFETY INFORMATION ................................................................ II
LIMITED WARRANTY .............................. ERROR! BOOKMARK NOT DEFINED.
Introduction
Thank you for purchasing this portable air conditioner.
This manual contains important information regarding the proper installation, use
and maintenance of your portable air conditioner. Following this manual will
ensure that your product will work at its peak performance and efficiency.
Please save the original product packaging in case you need to safely transport
your portable air conditioner.
For Your Records:
Please write down the model number and serial number
below for future reference. Both numbers are located on the
ratings label on the back of your unit and are needed to
obtain warranty service. You may also want to staple your
receipt to this manual as it is the proof of your purchase, and
is also needed for service under your warranty.
Model Number:
Serial Number:
Date of Purchase:
To better serve you, please do the following before contacting customer service:
xIf you received a damaged product, immediately contact the dealer that
sold you the product.
xRead and follow this instruction manual carefully to help you install, use
and maintain your portable air conditioner.
xRead the troubleshooting section of this manual as it will help you
diagnose and solve common issues.
First Time Operating Instructions
Before use, make sure all packaging labels and materials are all removed from
the unit. Be sure to keep track of all included parts and pieces before discarding
packaging materials. It is advised that you keep the original box and packaging
materials in case you are ever to move or ship the unit in the future.
Let the unit stand for at least 24 hours before you use it; this allows the cooling
components time to settle from transit. The instruction manual should be read
before use.
This owner’s manual is provided for reference use only. Specifications may
change without prior notice. Refer to the product label on the back of y our
portable air conditioner for the latest technical information
1
Parts Identification
r
r
A
Front View
Window Plate
with Hole
Oval Window
Kit Adapter
Exhaust Hose
Window Plate
Control Panel
Front Air Vent/
Louvers
Handle
Caste
Back View
Pre-filte
ir Intake
Exhaust Outlet
Upper Drain Valve
Air Intake/
Compressor pre-filter
Lower Drain Valve
Koldfront Portable Air Conditioner 2
CAUTION: Never operate
r
r
the air conditioner without
the pre-filter attached.
Installing the Carbon Filter
Your portable air conditioner ships with a pre-filter and an activated
carbon filter. The carbon filter will help remove contaminates and
odors from the air. It is recommended you replace the carbon filter
every two to three months, or as needed. It is necessary to clean
the pre-filter periodically. Follow the steps below to install the
carbon filter:
Filter frame
Pre-filte
Note: The size of the
carbon filter may vary.
1. Pull the pre-filter straight up.
Activated
carbon filte
2. Separate the filter frame from the pre-filter.
3. Place the activated carbon filter on the pre-filter.
4. Reattach the filter frame.
5. Insert the assembled pre-filter into the back of the unit.
3
Window Kit Installation Instructions
Preparations for installing
the window kit
NOTE: Some models
may ship with foam strips
to minimize air gaps and
for insulation purposes.
You must vent your portable air conditioner when running in it
cooling mode. Your unit includes a window exhaust kit that can be
used to vent the unit out a window.
Before you begin, make sure you have all the parts necessary for
installation.
Window Kit Parts:
Window Plate
Window Plate
with Hole
Oval Window
Kit Adapter
Exhaust Hose
NOTE: You may need to
contact your electrician if
your room’s circuit is not
able to power your unit.
If you have multiple windows, choose one that is near an electrical
outlet that will be able to provide sufficient power to your unit. See
the power requirements listed on the product label printed on the
side, or on the back of your portable air conditioner.
Your window kit can be installed on a horizontal or vertical sliding
window as shown in the following pictures:
Follow the instructions on the next pages to install the window kit.
Koldfront Portable Air Conditioner 4
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.