Kohler Mira Jump 7.5, Mira Jump 10.8, Mira Jump 8.5, Mira Sprint 8.5, Mira Sprint 9.5 Installation And User Manual

...
These instructions must be left with the user
Installation Guide
Mira Jump
7.5, 8.5, 9.5 and 10.8 kW Electric Shower
1224546-W2-D
For SPARES, ADVICE
or REPAIRS
Please call us on
(UK Only)
Mira Sprint
8.5, 9.5 and 10.8 kW Electric Shower
COMMISSIONING
SERVICING
© Kohler Mira Limited, May 2017
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product specications without notice.
FM 14648
CUSTOMER SERVICE
The guarantee applies solely to the original installation under normal use and to the original purchaser only. The product must be installed and maintained in accordance with the instructions given in this guide.
Servicing must only be undertaken by us or our appointed representative. Note! If a service visit is required the product must be fully installed and connected to services.
Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date
For shower ttings or consumable items we reserve the right to supply
replacement parts only.
The guarantee does not cover:
Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage,
chemical attack, corrosion, system debris or blocked lters) or where no
fault has been found with the product.
Water or electrical supply, waste and isolation issues.
Compensation for loss of use of the product or consequential or indirect loss of any kind.
Damage or defects caused if the product is repaired or modied by persons
not authorised by us or our appointed representative.
Accidental or wilful damage
Products purchased ex-showroom display.
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions. If this does not resolve the issue, contact us for help and advice.
Extended Guarantees
A selection of protection plans are available that enable you to cover repair
bills (excludes Eire). Ring 01922 471763 for more details.
Guarantee
Your product has the benet of our manufacture’s guarantee which starts from
date of purchase. This guarantee only applies in the United Kingdom and Republic of Ireland. To activate this guarantee, please return your completed
registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only).
Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose.
This guarantee is in addition to your statutory rights and is subject to the following conditions:
Helpdesk Service - Contact our Customer Services Team for
product advice, to purchase spare parts or accessories or to set up service visit. You can contact us via phone or e-mail - contact details below. Please provide your model name, power rating (if
applicable) and date of purchase.
Mira Showers Website (www.mirashowers.co.uk)
Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and popular spares, or request a service visit.
Spares and Accessories - We hold the largest stocks of genuine Mira spares and accessories. Contact us for a price or visit our website to purchase items from our accessory range and popular
spares. (Only available in the United Kingdom).
Service/Repairs - No one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period (Only available in the United Kingdom and Republic of
Ireland). Ask about our xed price service repairs.
To Contact Us
0844 571 5000
Fax: 01242 282595
E-mail:
www.mirashowers.co.uk/contactus
Mira Customer Services Dept
Cromwell Road, Cheltenham,
Gloucestershire
GL52 5EP
To Contact Us: Eire Only
01 531 9337
E-mail:
CustomerServiceEire@mirashowers.com
WARNING There are no user serviceable parts inside the shower.
Servicing of the shower must only be carried out by qualied,
competent personnel following the instructions provided in this guide and those provided with any spare part.
Before replacing any parts, ensure that the underlying cause of
the malfunction has been resolved.
Cleaning the Inlet Filter
Warning! Isolate the electrical and water supplies before removing
the cover. Remove the cover.
Remove the elbow from the inlet connector.
Note! Depending on your installation it may be necessary to remove the shower from the
wall to allow lter removal.
In this case isolate all supplies and follow steps 6 - 8 in reverse order as detailed in section: ‘INSTALLATION’.
Inlet Filter
Inlet Connector
Prise the lter from the inlet
connector assembly.
Rinse the lter under a
running tap to remove any lodged particles. If necessary, use a kettle descalent in accordance
with the manufacturer’s instructions. Ret the inlet lter and follow steps 7 and 10
as described in section: ‘INSTALLATION’.
Note! If the shower was removed from the wall, steps
6, 7, 8 and 10 will need to be followed as described in section:
‘INSTALLATION’.
Follow the steps detailed in section: ‘COMMISSIONING’ to prepare the shower for use.
No water or very
low ow rate
The heater tank is excessively scaled
Replace the heater tank assembly
The inlet lter is
blocked
Clean the inlet lter
The fuse is blown or the MCB / RCD has been tripped, indicating a possible electrical fault; for example, heater tank element failure
Switch on the power at the double pole switch
The on / off switching assembly is faulty
Replace on / off switching assembly
The start / stop switch is faulty
Replace start / stop switch
The solenoid coil is faulty
Replace solenoid coil
Water leaks from the bottom of the case near the outlet and there is
no ow from the
showerhead
The pressure relief valve in the tank has been triggered (usually due to a blocked
outlet), when the relief
valve operates a small rubber ball is ejected
Resolve the blocked outlet and replace the heater tank assembly
The water cannot be turned off
The on / off switching assembly is faulty
Replace on / off switching assembly
The start / stop switch is faulty
Replace start / stop switch
The supply pressure is below the minimum required
Check the static water pressure. Note that the static water pressure may fall below the minimum requirement when other appliances are drawing water, for example the dishwasher or the washing machine
Adjust temperature as required. Note! Flow rate will reduce when temperature setting is increased.
Temperature will rise further.
Turn power control to High.Temperature will rise slightly.
5 - 10 secs
COLD
HOT
109
5 - 10 secs
COLD
HOT
7 8
Water ows freely within a few
seconds, temperature remains cool
Turn power control to Eco.
COLD
0 - 15 secs
HOT
Push START/STOP button.Switch on the electrical supply.
5 6
4
3
1 2
Turn temperature control to the cold position.
Turn power control to low.
Use the terminal block location that is most appropriate for your installation i.e. If the electric supply is on the right hand side then use the right hand terminal block. Strip back sufficient outer cable insulation to enable routing to the terminal block.
Fit an earth sleeve to the earth wire. Insert the wires into the terminal block.
Tighten the screws in the terminal block, ensure the wires are secure and tight.
For falling or rising supplies the cover has thinned sections on the top and bottom that can be removed to allow entry of the supply pipe and electrical cables.
Cover
Screw
Screws
Thinned Section
Ensure the earth bonding complies with relevant regulations.
L (Live) = Brown wire
(Protective Earth) = Green /Yellow sleeved wire
N (Neutral) = Blue wire
8
Ensure the control dials are aligned with the spindles and replace the cover.
Tighten the three cover screws.
Do not use alternative screws to secure the cover. This can cause internal damage to the appliance.
Do not seal around the back of appliance.
Install the shower ttings (Refer to the Shower Fittings Installation and User Guide packed with the product).
The shower must be commissioned before use, please refer to section: ‘COMMISSIONING’.
This completes the installation.
9
10
11
12
13
Terminal
Block (LH)
Terminal
Block (RH)
Warning! There are no user serviceable components beneath the
cover of the appliance. In the event of a malfunction of the shower, the troubleshooting information below provides details on possible
causes and remedies that may be carried out by qualied, competent personnel. Non-qualied personnel should refer to the fault diagnosis
section in the users guide.
FAULT DIAGNOSIS
Symptom Possible Cause Possible Remedy
No hot water from the shower, with the controls in ECO/HIGH position
Insufcient water
supply pressure
Contact local water authority
Failure of the microswitch or thermal switch
Check the continuity of the switches, using a suitable continuity measuring device. Replace the switches as necessary
An internal wiring connection has failed
Check the integrity of the internal wiring
One of the heater tank elements has failed
Replace the heater tank assembly
Switch assembly fault Replace On / Off switching
assembly
The shower temperature cycles between hot and cold with power control in ECO/HIGH
The hose or showerhead is blocked
De-scale showerhead, check hose for kinks or damage and replace if necessary. Refer to the User Maintenance section of the user guide
The temperature is set too high. This is causing the thermal switch to turn off the heating element to reduce the water temperature
Turn the temperature control anticlockwise to reduce the water temperature or turn the power control to ECO. DO NOT TAMPER with the thermal switch
Turning the temperature control does not affect the water temperature
The ow regulator is
faulty
Replace the heater tank assembly
The hose or showerhead is blocked
De-scale showerhead, check hose for kinks or damage and replace if necessary. Refer to the User Maintenance section of the user guide
No water or very
low ow rate
The hose or showerhead is blocked
De-scale showerhead, check hose for kinks or damage and replace if necessary. Refer to the User Maintenance section of the user guide
The incoming water supply stop valves, or the appliance isolating valve is closed
Open the stop/isolating valve completely
Insufcient water
supply pressure
Contact the local water authority
Power LED does not illuminate when the pull cord is operated
Electrical supply failure
(MCB, pull cord etc.)
Check electrical supply
Power LED faulty Replace the wiring loom
Note! A slight hissing sound may be heard from the shower during operation. High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use.
A small amount of water may continue to drain over a few minutes.
13
11 12
Switch off the electrical supply.Push START/STOP button.
WIRING DIAGRAM
ACCESSORIES
Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this
guide) or from approved stockists or merchants.
Inlet Pipe Accessory
1788.443
Designed to simplify the
retrotting of a Mira shower
onto existing pipework. Note! Some adjustment of pipe length may be necessary.
SPARE PARTS
1693.331 Component Pack (Not illustrated)
1788.436 Screw Pack (Not illustrated)
1788.424
Mira Jump Cover Assembly
1788.425
Mira Sprint Cover Assembly
1788.439
Outlet Connector
1789.085
Latching Switch
1788.437
Terminal Block Assembly
1788.435
Inlet Filter
1788.434
Solenoid Coil
1788.429
On / Off Switching Assembly
1746.436
Thermal Switch
1788.433
Valve Clamp
NE L
MICROSWITCH
(LEFT)
MICROSWITCH
(RIGHT)
BLUE
GREY
BLUE
BROWN
BROWN
BROWN
GREEN
RED
RED
BROWN
BROWN
BLUE
BLUE
GREEN
BLUE
BROWN
BLUE
RED
NE L
GREEN
BROWN
BLUE
BLUE
TERMINAL
BLOCK
TERMINAL
BLOCK
LED
START /
STOP
SOLENOID
HEATER
TANK
1788.438
Earth Terminal Block Assembly
1788.440
Wire Loom and LED
1788.478 (7.5kW)
1788.426 (8.5kW)
1788.427 (9.5kW)
1788.428 (10.8kW)
Heater Tank Assembly (includes
microswitches)
Plumbing Variant
7.5 8.5 9.5 10.8
Min Dynamic Pressure 70 kPa
(0.7 bar)
70 kPa
(0.7 bar)
70 kPa
(0.7 bar)
100 kPa
(1.0 bar)
Max Dynamic Pressure 500 kPa (5.0 bar)
Max Static Pressure 1000 kPa (10 bar)
Min Static Pressure 50 kPa (0.5 bar)
Max Inlet Temperature 30°C
Min Inlet Temperature 2°C
Inlet Connection 15 mm Compression / Pusht Coupling
Max Water Hardness 200 ppm CaCO
3
Outlet Connection 1/2” BSP Male
Electrical Variant
7.5 8.5 9.5 10.8
Nominal Power at 240 V ac 7.5 kW 8.5 kW 9.5 kW 10.8 kW
Nominal Power at 230 V ac 6.9 kW 7.8 kW 8.7 kW 9.9 kW
Recommended MCB Rating 32 A 40 A 40A 45 A
Max Supply Cable Size 16 mm²
Recommended RCD Rating 30 mA tripping current
Recommended Isolator Switch
45 A double-pole with 3 mm contact
separation
Appliance Sealing Rating IP X4 - Suitable for installation in Zone 1
Max Ambient Temperature 30°C
Min Ambient Temperature 2°C
European Conformity Information
This range of electric showers complies with the following European directives: 2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive,
2011/65/EU RoHS Directive
This range of electric showers are high power appliances and are subject to conditional connection. If the main electrical supply fuse is rated less than 80 Amps, the local electricity supply company must be
contacted to conrm if the electrical supply is adequate. This range of showers complies with the requirements of the UK’s
water regulations.
Dimensions
Height 356 mm
Width 225 mm
Depth 107 mm
‘Snap Off’ section for rear entry
Terminal
Block (LH)
INTRODUCTION
SPECIFICATION
Documentation
1 x Electric Shower
1 x Installation Guide
1 x User Guide
1 x Guarantee Brochure
PACK CONTENTS
INSTALLATION REQUIREMENTS
1 x Installation Template (printed on
the inside of product carton)
1 x Component Pack
1x Showerhead
1x Hose
1 x Shower Fittings
PLUMBING
1. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any
particular regulation or practice specied by the local water
supply company.
2. Do not install the product in a position in which service access is limited.
3. Decide on a suitable position for the shower (minimum distance of 200 mm from the ceiling to allow for cover t and removal).
4. The shower is suitable for installation within the shower area
and is tted with a pressure relief valve. It must be positioned
over a water catchment area with the controls at a convenient height for the user.
5. The shower must be tted to a waterproof at and even wall
surface.
6. DO NOT t the shower to the wall and tile up to the case.
7. DO NOT seal the gap between the shower and the wall surface.
8. The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle.
9. The showerhead must be directed away from the shower unit, during normal use the showerhead must not spray directly on to the shower unit.
10. DO NOT apply excessive force to plumbing connections; always provide mechanical support when making plumbing connections. Any soldered joints should be made before connecting the shower.
11. The position of the shower and shower ttings must provide a
minimum gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin and a minimum
gap of 30 mm between the showerhead and the spill over level
of any toilet, bidet or other appliance with a Fluid Category 5
backow risk.
Note! There will be occasions when the hose retaining ring will
not provide a suitable solution for Fluid Category 3 installations, in these instances an outlet double checkvalve must be tted, this will increase the required supply pressure typically by 10kPa (0.1 bar). Double checkvalves tted in the inlet supply to the appliance cause
a pressure build up, which affect the maximum static inlet pressure
for the appliance and must not be tted. For Fluid category 5 double
checkvalves are not suitable.
Zone of
Backow Risk
30 mm
Minimum
Toilet or Bidet
FC5
Hand Basin
FC3
Bath or Shower
Tray FC3
Electric Shower
25 mm
Minimum
25 mm Minimum
Hose retaining ring tted and shower ttings xed at a suitable height preventing dirty water backow.
12. This shower is not designed to be plumbed directly from the rear. For rear-entry supply, add an elbow to the supply pipe and connect as a rising or a falling supply.
13. If pipework and/or electrical cables enter the shower from the
rear through a hole in the wall provision must be made to prevent water ingress back into the wall structure.
14. This shower is intended to be permanently connected to the mains water supply, only use the inlet connection supplied with the shower.
DO NOT use any other type of tting.
15. A full bore/non restrictive servicing valve must be tted in a
readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose
washer plate (jumper) as this can lead to a build up of static
pressure.
16. A water treatment device should be installed where the water hardness may exceed 200 ppm. Malfunctions caused by
excessive limescale formation are not covered by this shower’s guarantee (see back page for details).
17. The installation must not cause the hose to be sharply kinked during normal use.
18. DO NOT perform the electrical installation until the plumbing has been completed and checked for leaks.
ELECTRICAL
1. The electrical installation must comply with BS 7671 (commonly
referred to as the IEE Wiring Regulations) and all relevant
building regulations, or any particular regulation or practice
specied by the local electricity supply company.
2. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
3. The shower must be earthed. Ensure any supplementary bonding complies with the relevant regulations.
4. This shower is intended to be permanently connected to the
xed electrical wiring of the mains system. A separate supply
must be provided from the consumer unit to the shower.
5. DO NOT supply any other electrical equipment including extractor fans or pumps via this product.
6. This shower must be provided with means for local disconnection
that is incorporated into the xed wiring in accordance with the
relevant local wiring regulations. This must be a double pole
switch, which has at least 3 mm contact separation in each pole.
The switch can be a ceiling mounted pull-cord type within the
shower room or a wall mounted switch tted in the applicable
zone area.
7. For new installations a 30mA Residual Current Device (RCD)
must be incorporated into the electrical supply to this shower in accordance with current wiring regulations. When replacing
an existing electric shower we recommend that a 30mA RCD
be incorporated in accordance with current wiring regulations if not already provided
8. DO NOT apply excessive force to the terminal block.
9. All electrical connections should be checked for tightness to prevent overheating before switching on the electrical supply.
Inlet Supply
Pusht
Elbow
Inlet Connector
8
9
Thank you for choosing a Mira shower. To enjoy the full potential of your new shower, please take time to read this guide thoroughly, and keep it handy for future reference. Products manufactured by Kohler Mira Ltd are designed to be safe, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations. Follow all warnings, cautions and instructions contained in this guide, and on, or inside the shower. This guide is also available in electronic format on our website or by contacting customer services. This product has separate controls for power selection and for
temperature/ow adjustment. A unique ow regulator stabilises any temperature changes caused by water pressure uctuations, which can result from taps being turned on or off or toilets being ushed.
Electrical and electronic devices contain a range of materials that can be separated for recycling and used in new products.
This shower should not be disposed of with your general household waste. When this shower has reached the end of its serviceable life please take it to a recognised WEEE (Waste Electrical and Electronic
Equipment) collection facility such as your local civic amenity site
for recycling.
Your local authority or retailer will be able to advise you of your nearest collection facility.
Mira Electric Showers covered by this guide:
Product kW Model Number Colour
Mira Jump
7.5 J08 Hb
White / Chrome
8.5 J08 Db
9.5 J08 Eb
10.8 J08 Fb
Mira Sprint
8.5 J08 Da
9.5 J08 Ea
10.8 J08 Fa
Guarantee
This product has been designed for domestic use only, Mira Showers guarantee this product against any defect in materials or workmanship
for a period of two years from the date of purchase (shower ttings for one year).
For terms and conditions, refer to the back cover of this guide.
Domestic
Light Commercial
Heavy Commercial
Healthcare
Recommended Usage
IMPORTANT SAFETY INFORMATION
WARNING – This shower can deliver scalding temperatures, cause re, electric shock or other personal injury if not installed, operated or maintained in accordance with the instructions,
warnings and cautions contained in this guide and on or inside the appliance.
Please read the important safety information and the installation requirements detailed in this guide before installing the shower. Failure to follow the instructions provided with this shower will invalidate the guarantee.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:
1. Installation of this shower must be carried out in accordance
with these instructions by qualied, competent personnel.
2. Isolate the electrical and water supplies before commencing installation. The electricity must be isolated at the consumer unit and the appropriate circuit fuse removed, if applicable. Mains connections are exposed when the cover is removed.
3. DO NOT install the shower in areas with high humidity and temperature (i.e. steam rooms and saunas).
4. DO NOT install the shower where it may be exposed to freezing conditions. Ensure that any pipework that could become frozen is properly insulated.
5. DO NOT switch the shower on if there is a possibility that the water in the shower is frozen.
6. DO NOT switch the shower on if water starts leaking from the shower case. Isolate the electrical supply to the shower immediately.
7. DO NOT connect the outlet of the shower to any tap, control valve, trigger operated handset or showerhead other than that specified for use with this shower. Only Kohler Mira recommended accessories should be used.
8. The water supplies to this product must be isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.
9. DO NOT perform any unspecied modications, or drill or cut holes in the product other than as instructed by this guide. When servicing only use genuine Kohler Mira replacement parts.
10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
11. Read all installation instructions before installing this shower.
12. Upon completion of the installation, make sure that the user is familiar with the operation of the shower, and leave this guide and the user guide with the owner.
7
Connect the inlet supply pipe to the inlet connector using a
push t elbow or an elbow with
compression nuts and olives.
Important! Do Not use pusht
elbows that require specialist tools for removal. Access
to the inlet lter is required
periodically and so any connector needs to be easily removed for maintenance.
Note! When making connections to the shower. Do not use jointing paste products as damage to the shower will occur.
Turn on the water supply and check connection for leaks.
L (Live) = Brown wire
(Protective Earth) =
Green / Yellow sleeved wire
N (Neutral) = Blue wire
For falling or rising supplies the cover has thinned sections on the top and bottom that can be removed to allow entry of the supply pipe and electrical cables.
Ensure the control dials are aligned with the spindles and replace the cover.
Tighten the three cover screws.
Do not use alternative screws to secure the cover. This can cause internal damage to the appliance.
Do not seal around the back of appliance.
Install the shower ttings (Refer to the Shower Fittings Installation and User Guide packed with the product).
11
Replacing an Existing Electric Shower
This electric shower can replace showers of approximate size and shape. Terminal Blocks are provided on both the left and right for convenience when replacing a shower. If the water entry point is on the right hand side of the shower then you will need to alter the incoming pipework as shown below. The Mira Inlet Pipe Accessory can be used to simplify this process. Refer to section: ‘ACCESSORIES’.
Warning! Isolate the electrical and water supplies.
From the new shower, remove the three screws that hold the cover on then remove the cover.
Existing pipework locations
Disconnect and remove the old shower from the wall.
1
‘Snap Off’ case sections
are provided for ease of installation when using existing right side, rear entry pipework.
Cover
Screw
Screws
10
Cover
Screw
Screws
2
Thinned Section
Terminal
Block (RH)
Terminal
Block (LH)
Terminal
Block (RH)
Terminal Blocks are provided on both the left and right for convenience. Use the terminal block location that is most appropriate for your installation i.e. If the electric supply is on the right hand side then use the right hand terminal block.
Strip back sufcient outer cable
insulation to enable routing to the terminal block.
Fit an earth sleeve to the earth wire.
Insert the wires into the terminal block.
Tighten the screws in the terminal block, ensure the wires are secure and tight.
Ensure the earth
bonding complies with
relevant regulations.
INSTALLATION
Fitting a New Shower
Plumbing and Electrical Schematic
Cover
Screw
Screws
2
1
Falling
(entering the shower
from the top).
Rising
(entering the shower
from the bottom).
Remove the three screws that hold the cover on and remove the cover.
Use the Installation Template provided (printed on the product
carton), together with a spirit level to mark the positions of
the three xing holes. Note! The shower should be positioned at least 200 mm from
the ceiling. Ensure that there are sufcient lengths of supply
pipe and electrical cable to reach the connection points as shown on the template.
Drill three holes to suit the xing screws and wall plugs.
Caution! Do not drill into cables or pipes in the wall.
4
Determine the direction and route of the incoming water supply:
Note! - DO NOT use an incoming supply entering the shower directly from the back. Add an elbow to the supply pipe and connect it as a rising or falling supply.
5
6
Secure the shower to the wall with xing screws and wall plugs (supplied) or appropriate wall xings for your installation.
Thoroughly ush the supply pipe.
3
10. DO NOT switch on the electrical supply until the plumbing has been completed and checked for leaks.
Warning! Isolate the electrical and water supplies before installing the shower.
Place the shower on the wall where the previous shower was installed and mark the positions of the three xing holes.
Note! Ensure that there are sufcient lengths of supply pipe
and electrical cable to reach the connection points.
3
Remove the shower and drill three holes to suit the xing
screws and wall plugs.
Caution! Do not drill into cables or pipes in the wall.
4
Thoroughly flush the supply pipe.
5
Secure the shower to the
wall with xing screws and wall plugs (supplied) or appropriate wall xings for
your installation.
6
Connect the inlet supply pipe to the inlet connector
using a push t elbow or
an elbow with compression nuts and olives.
Turn on the water supply and check connection for leaks.
7
12
13
The shower must be commissioned before use, please refer to section: ‘COMMISSIONING’.