Kohler Mira Calibre Series, Mira Calibre ER, Mira Calibre EV Installation Manual

Mira Calibre Thermostatic Shower
These instructions must be left with the user
Installation Guide
For SPARES, ADVICE
or REPAIRS
Please call us on
0844 571 5000
(UK Only)
CONTENTS
Introduction 3
Guarantee 3
Recommended Usage 3
Patents and Design Registration 3
Safety Warnings 4 Pack Contents 5
Mira Calibre EV 5
Mira Calibre ER 6
Specications 7
Pressures 7
Temperatures 7
Thermostatic Shut-down 7
Connections 7
Dimensions 8
Installation 9
Suitable Plumbing Systems 9
General 9
Mira Calibre EV Installing the Shower Mixer 10
Installing the Slide Bar and Shower Handset 14
Mira Calibre ER Installing the Shower Mixer 16
Installing the Riser Pipe and Showerhead 20
Commissioning 22 Maximum Temperature Setting 22
Mira Calibre EV 22
Mira Calibre ER 24
Operation 26
Mira Calibre EV 26
Height Adjustment 26
Changing the Spray Setting 27
Mira Calibre ER 28
Showerhead Adjustment 28
User Maintenance 29
Fault Diagnosis 29
Lubricants 29
Cleaning 29
Spray Plate 29
Spare Parts 30
Mira Calibre EV 30
Mira Calibre ER 32
Customer Service 36
If you experience any difficulty with the installation or operation of your new thermostatic mixer, please refer to ‘Fault Diagnosis’ before contacting Mira Showers. Our contact details can be found on the back cover of this guide.
INTRODUCTION
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
The Mira Cal bre EV is a thermostatic mixing shower with integral slidebar, hose and Mira 360 shower handset.
The Mira Calibre ER is a thermostatic mixing
shower with integral riser rail and xed height
250mm showerhead attached with a ball joint.
The thermostatic mixing valve incorporates a temperature sensing unit, which provides an almost immediate response to changes in water temperature or pressure to maintain a comfortable shower. An adjustable maximum temperature stop is provided to limit the showering temperature to a preset level. This is a safety feature that can be adjusted after installation (see “Commissioning”
for further details) Inlet water lters are tted to
protect the internal mechanism.
Recommended Usage
Application Valve with Fittings
Domestic
Light Commercial
Heavy Commercial
Healthcare
ü
ü
û
û
Patents and Design Registration
Patents:
GB 2 422 886
Patent Applications:
Europe 07015846.4
USA 2010-0219255-A1
Products manufactured by us are safe and risk-free, provided they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.
Guarantee
For domestic installations, Mira Showers guarantee the Mira Calibre Thermostatic Mixer against any defect in materials or workmanship for a period of ve years from the date of purchase.
The shower handset, hose and clamp bracket supplied with the Mira Cal bre EV model are guaranteed for one year from date of purchase.
The showerhead supplied with the Mira Cal bre ER model is guaranteed for one year from date of purchase.
For terms and conditions refer to ‘Customer Services’ on the back cover of this guide.
Design Registration:
001240527 - 0002 001240527 - 0004 001312649 - 0014 001004022
SAFETY WARNINGS
WARNING - This product can deliver scalding temperatures if not installed, operated or maintained in accordance with the instructions, warnings and cautions contained in this guide.
The function of a thermostatic mixing valve is to deliver water consistently at a safe temperature. In keeping with every other mechanism, it cannot be considered as functionally infall ble and as such, cannot totally replace a supervisor’s vigilance where that is necessary. Provided it is installed, commissioned, operated and maintained within manufacturers recommendations, the risk of failure, if not eliminated, is reduced to the minimum achievable.
Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided:
1. They are installed, commissioned, operated
and maintained in accordance with the manufacturer’s recommendations.
2. Periodic attention is given, when necessary, to
maintain the product in good functional order.
Caution!
1. Read all of these instructions.
2. Retain this guide for later use.
3. Installation must be carried out in accordance
with these instructions, and must be conducted by designated, qualified and competent personnel.
4. Provision must be made to prevent water
ingress back into the wall structure.
5. DO NOT fit the product where it may be exposed to freezing conditions. DO NOT operate this appliance if it is frozen. Allow the appliance to thaw and check for leaks before using.
6. Make sure that any pipework that could become frozen is properly insulated.
7. DO NOT overtighten grubscrews as product damage may occur. Use hexagonal key provided and hand tighten only, DO NOT use power tools.
8. All pipework must be checked for leaks before the product installation is completed. The product should be pressurised and the inlet and outlet connections inspected.
9. Pass on this guide in the event of change of ownership of the product.
10. Follow all warnings, cautions and instructions contained in this guide.
11. Make sure that you fully understand how
to operate this shower before use, read all operating instructions and retain this guide for future reference.
12. Care is required when adjusting flow or
temperature. Make sure that the temperature has stabilised before use.
13. This product is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety.
14.
Children should be supervised to ensure that
they do not play with the product.
15. DO NOT perform any unspecied modications
to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts.
16. If the shower is dismantled during installation
or servicing then upon completion the product must be inspected to ensure all connections are tight and that there are no leaks.
17.Only Mira recommended outlet ttings should
be used.
18. Sunburn or skin conditions can increase your
sensitivity to hot water. Make sure that you set the shower to a cooler temperature.
19. The water supplies to this product must be
isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.
20. When this product has reached the end of its
serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre EV
q 1 x Thermostatic Mixer
q 1 x Slide Bar
q 1 x Shower Handset
q 2 x Rubber Washer
q 1 x Clamp Bracket
q 1 x Shower Hose
q 1 x 2.5mm
Hexagonal Key
1 x 2mm
q
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre ER
q 1 x Thermostatic Mixer
q 1 x Overhead Arm
q 1 x Showerhead
q 1 x Riser Pipe
q 1 x 2.5mm
Hexagonal Key
q 1 x 2mm
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
SPECIFICATIONS
Pressures
Max Static Pressure: 10 Bar.
•
Max Maintained Pressure: 5 Bar.
•
Min Maintained Pressure (Gravity System):
•
0.5 Bar (0.5 bar = 5 Metre head from cold tank outlet to showerhead).
For optimum performance supplies should be
•
at nominally equal pressure.
Temperatures
Factory Pre-set (Max Blend) Shower: 45°C
•
(can be altered after installation if required). Optimum Thermostatic Control Range: 35°C
•
to 45°C achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures.
Recommended Hot Supply: 60°C to 65°C
•
Note! For safety and performance reasons it is recommended that the maximum hot water temperature should not exceed 65°C.
Cold Water Range: up to 25°C.
•
Minimum Recommended Differential between
•
Hot Supply and Outlet Temperature: 12°C.
Thermostatic Shut-down
For safety, the thermostat will shut off the
•
mixing valve within 2 seconds if either supply fails (achieved only if the blend temperature has a minimum differential of 12°C from either inlet supply).
Connections
The thermostatic mixer can only be installed with rear supply inlets and the supply pipework must be connected as shown.
Inlets: Pushfit 15mm Copper pipe to
•
•
Caution! This product does not allow for
reversed inlets and will not function if
ttedincorrectly.
Do not use plastic pipe with this
product.Theltersmustbettedand
are only suitable for 15mm copper
BS EN 1057.
Not suitable for 14.7mm copper
pipe manufactured in Éire!
Outlets: ½” BSP at face to hose and handset.
½” BSP at face to showerhead.
pipework.
Mira Calibre EV
Cold
Mira Calibre ER
Hot
Hot
Outlet
Outlet
Cold
Dimensions
Mira Calibre ERMira Calibre EV
362
71
250
925 max.
910
59
59
200
145
IMPORTANT!
The Slide Bar and Riser Pipe MUST NOT be cut or extended to adjust the height. The above dimensions are to be adhered to.
145
200
All dimensions in mm
INSTALLATION
Suitable Plumbing Systems
Mains Pressurised Instantaneous Hot Water System (Combination Boiler):
The product can be installed with systems of this type with balanced pressures. (Recommended Minimum Maintained Pressure: 0.5 Bar).
Unvented Mains Pressure System:
The product can be installed with an unvented, stored hot water system.
Pumped System:
The product can be installed with an inlet pump (twin impeller). The pump must be installed in a suitable location and in accordance with its instructions.
Gravity System:
The product can be installed on a gravity head system with a minimum head of 5m (0.5 bar), measured from the cold water tank outlet to the showerhead when installed (ER) or from the cold water tank outlet to the shower handset at the highest position when installed (EV).
General
The installation must be carried out in accordance with these instructions, and must be conducted by
designated, qualied and competent personnel.
The installation must comply with the ‘Water Supply Regulations 1999 (Water Fittings)’ or
any particular regulations and practices, specied
by the local water company or water undertakers.
Note!
The product includes checkvalves tted to the
mixer inlets and shower handset (EV). Make sure that all site requirements correspond to
the information given in ‘Specications’.
and avoid any strain on the connections.
5. Hidden pipework dead-legs should be kept to
a minimum.
6. Decide on a suitable position for the Mixer,
make sure that there is sufcient headroom
and ceiling clearance to install the integral slidebar and showerhead.
Avoid positioning the wall mounting between
tiles. The xing is strongest in the centre of a
tile.
7. The inlet pipework must be ushed thoroughly before tting the mixer.
8. Upon completion of the installation, the product must be checked to make sure there are no leaks.
1. The thermostatic mixer must not be installed
in an area where it may freeze.
2. For stud partitions alternative xings may be
required (not supplied).
3. Isolating valves must be installed as close
to the thermostatic mixer as reasonably practicable for ease of maintenance.
4. Hidden pipework must be rigidly supported
Mira Calibre EV Installing the Shower Mixer
1. The mixer must be tted vertically as illustrated
and can only be installed with rear supply inlets.
2. Determine the route for the hot and cold supply
pipework.
Note! Make sure that there is sufcient ceiling
clearance to install the integral slidebar. (Minimum of 110cm from ceiling to the centre of upper inlet.)
3. Remove the backplate from the mixer by loosening the two grubscrews with the 2.5mm hexagonal key supplied.
Backplate
Cold
Cold to the Upper Inlet
•
Hot to the Lower Inlet
•
Bottom Outlet
•
Hot
4. Using the backplate as a guide, mark the
positions of the pipe centres.
110cm minimum from ceiling
Outlet
10
5. Install the supply pipework. Make allowance
for the pipework to extend a minimum of 50mm
from the nished wall surface (the pipework will
be trimmed back later).
IMPORTANT! support pipework from rear to aid valve assembly
Panel / Partition Wall
Solid Wall
50mm minimum from
nished wall
Noggin for slide bar wall mounting
6. Finish the wall surface to cover the pipework.
7. Using an appropriate pipe cutter, trim the protruding pipework back to 30 - 35mm.
8. Remove all burrs and sharp edges from the pipework.
30 - 35mm
Noggin for pipework
9. Fit the backplate over the pipes and mark the
xing holes.
10. Remove the backplate and drill the holes. For solid walls use a 6mm drill for the wall plugs supplied. For other types of wall structure alternative fixings may be required (not supplied).
Channels cut for pipework
11
Loading...