If you experience any difficulty with the
installation or operation of your new
thermostatic mixer, please refer to ‘Fault Diagnosis’ before contacting Mira Showers.
Our contact details can be found on the back
cover of this guide.
2
Page 3
INTRODUCTION
Thank you for purchasing a quality Mira product.
To enjoy the full potential of your new product,
please take time to read this guide thoroughly,
having done so, keep it handy for future reference.
The Mira Cal bre EV is a thermostatic mixing
shower with integral slidebar, hose and Mira 360
shower handset.
The Mira Calibre ER is a thermostatic mixing
shower with integral riser rail and xed height
250mm showerhead attached with a ball joint.
The thermostatic mixing valve incorporates a
temperature sensing unit, which provides an
almost immediate response to changes in water
temperature or pressure to maintain a comfortable
shower. An adjustable maximum temperature stop
is provided to limit the showering temperature to
a preset level. This is a safety feature that can be
adjusted after installation (see “Commissioning”
for further details) Inlet water lters are tted to
protect the internal mechanism.
Recommended Usage
ApplicationValve with Fittings
Domestic
Light Commercial
Heavy Commercial
Healthcare
ü
ü
û
û
Patents and Design Registration
Patents:
GB 2 422 886
Patent Applications:
Europe 07015846.4
USA 2010-0219255-A1
Products manufactured by us are safe and
risk-free, provided they are installed, used and
maintained in good working order, in accordance
with our instructions and recommendations.
Guarantee
For domestic installations, Mira Showers
guarantee the Mira Calibre Thermostatic Mixer
against any defect in materials or workmanship for
a period of ve years from the date of purchase.
The shower handset, hose and clamp bracket
supplied with the Mira Cal bre EV model are
guaranteed for one year from date of purchase.
The showerhead supplied with the Mira Cal bre ER
model is guaranteed for one year from date of
purchase.
For terms and conditions refer to ‘Customer Services’ on the back cover of this guide.
WARNING - This product can deliver scalding
temperatures if not installed, operated
or maintained in accordance with the
instructions, warnings and cautions contained
in this guide.
The function of a thermostatic mixing valve is to
deliver water consistently at a safe temperature. In
keeping with every other mechanism, it cannot be
considered as functionally infall ble and as such,
cannot totally replace a supervisor’s vigilance
where that is necessary. Provided it is installed,
commissioned, operated and maintained within
manufacturers recommendations, the risk
of failure, if not eliminated, is reduced to the
minimum achievable.
Mira thermostatic mixers are precision engineered
and should give continued safe and controlled
performance, provided:
1. They are installed, commissioned, operated
and maintained in accordance with the
manufacturer’s recommendations.
2. Periodic attention is given, when necessary, to
maintain the product in good functional order.
Caution!
1. Read all of these instructions.
2. Retain this guide for later use.
3. Installation must be carried out in accordance
with these instructions, and must be conducted
by designated, qualified and competent
personnel.
4. Provision must be made to prevent water
ingress back into the wall structure.
5.DO NOT fit the product where it may be
exposed to freezing conditions. DO NOT
operate this appliance if it is frozen. Allow the
appliance to thaw and check for leaks before
using.
6. Make sure that any pipework that could
become frozen is properly insulated.
7.DO NOT overtighten grubscrews as product
damage may occur. Use hexagonal key
provided and hand tighten only, DO NOT use
power tools.
8. All pipework must be checked for leaks before
the product installation is completed. The
product should be pressurised and the inlet
and outlet connections inspected.
9. Pass on this guide in the event of change of
ownership of the product.
10. Follow all warnings, cautions and instructions
contained in this guide.
11. Make sure that you fully understand how
to operate this shower before use, read all
operating instructions and retain this guide for
future reference.
12. Care is required when adjusting flow or
temperature. Make sure that the temperature
has stabilised before use.
13. This product is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or instruction
concerning the use of the product by a person
responsible for their safety.
14.
Children should be supervised to ensure that
they do not play with the product.
15. DO NOT perform any unspecied modications
to the shower or its accessories. When
servicing only use genuine Kohler Mira
replacement parts.
16. If the shower is dismantled during installation
or servicing then upon completion the product
must be inspected to ensure all connections
are tight and that there are no leaks.
17.Only Mira recommended outlet ttings should
be used.
18. Sunburn or skin conditions can increase your
sensitivity to hot water. Make sure that you set
the shower to a cooler temperature.
19. The water supplies to this product must be
isolated if the product is not to be used for a
long period of time. If the product or pipework
is at risk of freezing during this period they
should also be drained of water.
20. When this product has reached the end of its
serviceable life, it should be disposed of in a
safe manner, in accordance with current local
authority recycling, or waste disposal policy.
4
Page 5
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre EV
q 1 x Thermostatic Mixer
q 1 x Slide Bar
q 1 x Shower Handset
q 2 x Rubber Washer
q 1 x Clamp Bracket
q 1 x Shower Hose
q 1 x 2.5mm
Hexagonal Key
1 x 2mm
q
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
5
Page 6
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre ER
q 1 x Thermostatic Mixer
q 1 x Overhead Arm
q 1 x Showerhead
q 1 x Riser Pipe
q 1 x 2.5mm
Hexagonal Key
q 1 x 2mm
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
6
Page 7
SPECIFICATIONS
Pressures
Max Static Pressure: 10 Bar.
•
Max Maintained Pressure: 5 Bar.
•
Min Maintained Pressure (Gravity System):
•
0.5 Bar (0.5 bar = 5 Metre head from cold
tank outlet to showerhead).
For optimum performance supplies should be
•
at nominally equal pressure.
Temperatures
Factory Pre-set (Max Blend) Shower: 45°C
•
(can be altered after installation if required).
Optimum Thermostatic Control Range: 35°C
•
to 45°C achieved with supplies of 15°C cold,
65°C hot and nominally equal pressures.
Recommended Hot Supply: 60°C to 65°C
•
Note! For safety and performance reasons it
is recommended that the maximum hot water
temperature should not exceed 65°C.
Cold Water Range: up to 25°C.
•
Minimum Recommended Differential between
•
Hot Supply and Outlet Temperature: 12°C.
Thermostatic Shut-down
For safety, the thermostat will shut off the
•
mixing valve within 2 seconds if either supply
fails (achieved only if the blend temperature
has a minimum differential of 12°C from either
inlet supply).
Connections
The thermostatic mixer can only be installed with
rear supply inletsand the supply pipework must
be connected as shown.
Inlets: Pushfit 15mm Copper pipe to
•
•
Caution!
This product does not allow for
reversed inlets and will not function if
ttedincorrectly.
Do not use plastic pipe with this
product.Theltersmustbettedand
are only suitable for 15mm copper
BS EN 1057.
Not suitable for 14.7mm copper
pipe manufactured in Éire!
Outlets: ½” BSP at face to hose and handset.
½” BSP at face to showerhead.
pipework.
Mira Calibre EV
Cold
Mira Calibre ER
Hot
Hot
Outlet
Outlet
Cold
7
Page 8
Dimensions
Mira Calibre ERMira Calibre EV
362
71
250
925 max.
910
59
59
200
145
IMPORTANT!
The Slide Bar and Riser Pipe MUST NOT be cut or extended to adjust the height.
The above dimensions are to be adhered to.
145
8
200
All dimensions in mm
Page 9
INSTALLATION
Suitable Plumbing Systems
Mains Pressurised Instantaneous Hot Water
System (Combination Boiler):
The product can be installed with systems of this
type with balanced pressures. (Recommended
Minimum Maintained Pressure: 0.5 Bar).
Unvented Mains Pressure System:
The product can be installed with an unvented,
stored hot water system.
Pumped System:
The product can be installed with an inlet pump
(twin impeller). The pump must be installed in
a suitable location and in accordance with its
instructions.
Gravity System:
The product can be installed on a gravity head
system with a minimum head of 5m (0.5 bar),
measured from the cold water tank outlet to the
showerhead when installed (ER) or from the cold
water tank outlet to the shower handset at the
highest position when installed (EV).
General
The installation must be carried out in accordance
with these instructions, and must be conducted by
designated, qualied and competent personnel.
The installation must comply with the ‘Water
Supply Regulations 1999 (Water Fittings)’ or
any particular regulations and practices, specied
by the local water company or water undertakers.
Note!
The product includes checkvalves tted to the
mixer inlets and shower handset (EV).
Make sure that all site requirements correspond to
the information given in ‘Specications’.
and avoid any strain on the connections.
5. Hidden pipework dead-legs should be kept to
a minimum.
6. Decide on a suitable position for the Mixer,
make sure that there is sufcient headroom
and ceiling clearance to install the integral
slidebar and showerhead.
Avoid positioning the wall mounting between
tiles. The xing is strongest in the centre of a
tile.
7. The inlet pipework must be ushed thoroughly
before tting the mixer.
8. Upon completion of the installation, the product
must be checked to make sure there are no
leaks.
1. The thermostatic mixer must not be installed
in an area where it may freeze.
2. For stud partitions alternative xings may be
required (not supplied).
3. Isolating valves must be installed as close
to the thermostatic mixer as reasonably
practicable for ease of maintenance.
4. Hidden pipework must be rigidly supported
9
Page 10
Mira Calibre EV
Installing the Shower Mixer
1. The mixer must be tted vertically as illustrated
and can only be installed with rear supply
inlets.
2. Determine the route for the hot and cold supply
pipework.
Note! Make sure that there is sufcient ceiling
clearance to install the integral slidebar.
(Minimum of 110cm from ceiling to the centre
of upper inlet.)
3. Remove the backplate from the mixer by
loosening the two grubscrews with the 2.5mm
hexagonal key supplied.
Backplate
Cold
Cold to the Upper Inlet
•
Hot to the Lower Inlet
•
Bottom Outlet
•
Hot
4. Using the backplate as a guide, mark the
positions of the pipe centres.
110cm minimum
from ceiling
Outlet
10
Page 11
5. Install the supply pipework. Make allowance
for the pipework to extend a minimum of 50mm
from the nished wall surface (the pipework will
be trimmed back later).
IMPORTANT!
support pipework
from rear to aid valve
assembly
Panel / Partition Wall
Solid Wall
50mm
minimum from
nished wall
Noggin for
slide bar
wall mounting
6. Finish the wall surface to cover the pipework.
7. Using an appropriate pipe cutter, trim the
protruding pipework back to 30 - 35mm.
8. Remove all burrs and sharp edges from the
pipework.
30 - 35mm
Noggin for
pipework
9. Fit the backplate over the pipes and mark the
xing holes.
10. Remove the backplate and drill the holes. For
solid walls use a 6mm drill for the wall plugs
supplied. For other types of wall structure
alternative fixings may be required (not
supplied).
Channels cut
for pipework
11
Page 12
11. Ret the backplate and secure to the wall using
the wallplugs and xing screws (supplied).
12. Fit the collets onto the inlet pipework. Make
sure the surfaces of the inlet pipes are clean
and free from debris e.g dried plaster or grout.
Collet
13. Flush both the hot and cold pipework
thoroughly to remove any debris.
14. Fit the inlet lters into the pipes.
Important! Make sure the backplate is vertical.
Inlet Filter
12
Page 13
15. Align the mixer with the inlet pipes and push
on fully. Secure the mixer to the backplate, but
do not overtighten the grubscrews.
Note! Make sure that the grubscrews are
engaged fully in the valve body grooves.
Make sure that the slot for removing the
concealing plate is at the bottom.
Concealing
Plate
OFF
ON
16. Perform an inlet leak test.
Turn the flow lever to the OFF position
and restore the water flow to each of the
inlets. Slowly turn the mixer ON so that a
small amount of water ows from the outlet
(make sure the water is able to drain to a waste
outlet or is caught in a receptacle e.g. bucket
or jug). Turn the mixer off and look for water
leaks around each of the inlets.
If a leak is detected check the following:
i. The supply pipework is 15mm copper BS
EN 1057
ii. The supply pipework must extend between
30 and 35mm from the finished wall
surface.
iii. The supply pipework must be supported to
aid valve assembly.
iv. The internal mixer seals are damaged/
missing. Contact Mira Customer Services.
(See ‘Customer Services’ on the back
cover for details.)
17.Clip the concealing plate onto the backplate.
13
Page 14
Installing the Slide Bar and
Shower Handset
1. Isolate the water supplies to prevent accidental
operation of the shower.
2. Assemble the clamp bracket onto the slide bar.
3. Use the slide bar as a guide to mark the
position of the wall mounting screw in line with
the mixer.
4. Drill a 13mm diameter hole for the wall
mounting plug.
Caution! Avoid drilling into concealed
water pipes or electrical cables.
5. Fix the wall mounting using the plug and screw
supplied. Tighten the screw using a 5mm
hexagonal driver (not supplied).
6. Fit the slidebar to the mixer and the wall
mounting.
7. Fit the spreader screw through the top of
the slide bar using the 2mm hexagonal key
(supplied).
Wall
Mounting
Plug
Wall
Mounting
Metal Washer
Wall Mounting
Screw
Spreader
Screw
Clamp
Bracket
TOP
Mixer
Care required when assembling
to avoid product damage.
continued...
14
Page 15
8. Fit the hose and shower handset.
Note! The hose is supplied with a straight
end and a tapered end. Fit the tapered end to
the shower handset. Be sure to t the rubber
washers to both ends of the hose.
Rubber
Washer
Rubber
Washer
Straight
9. Restore the water supplies and test the shower
functions correctly (see ‘Operation’). Check
for leaks from all connections.
10. Important! If required, t the ow regulator
supplied.
11. If the maximum showering temperature requires
adjustment, refer to ‘Commissioning’.
12. Having completed the installation, make sure
that the user is familiar with the operation of
the shower.
Tapered
Flow
Regulator
15
Page 16
Mira Calibre ER
Installing the Shower Mixer
1. The thermostatic mixer must be tted vertically
as illustrated and can only be installed with rear
supply inlets.
2. Determine the route for the hot and cold supply
pipework.
Note! Make sure that there is sufficient
ceiling clearance to install the riser pipe and
showerhead. (Minimum of 110 centimetres
from ceiling to the centre of upper inlet.)
Outlet
3. Remove the backplate away from the mixer.
Backplate
Hot
Hot to the Upper Inlet
•
Cold to the Lower Inlet
•
Top Outlet
•
Cold
4. Using the backplate as a guide, mark the
positions of the pipe centres.
110cm minimum
from ceiling
16
Page 17
5. Install the supply pipework. Make allowance
for the pipework to extend a minimum of 50mm
from the nished wall surface (the pipework will
be trimmed back later).
Panel / Partition Wall
Noggin for
overhead arm
wall mounting
Noggin for
pipework
Solid Wall
IMPORTANT!
support pipework
from rear to aid valve
assembly
50mm
minimum from
nished wall
6. Finish the wall surface to cover the pipework.
7. Using an appropriate pipe cutter, trim the
protruding pipework back to 30 - 35mm.
8. Remove all burrs and sharp edges from the
pipework.
30 - 35mm
9. Fit the backplate over the pipes and mark the
xing holes.
10. Remove the backplate and drill the holes. For
solid walls use a 6mm drill for the wall plugs
supplied. For other types of wall structure
alternative fixings may be required (not
supplied).
Channels cut
for pipework
17
Page 18
11. Ret the backplate and secure to the wall using
the wallplugs and xing screws (supplied).
12. Fit the collets onto the inlet pipework. Make
sure the surfaces of the inlet pipes are clean
and free from debris e.g dried plaster or grout.
Collet
13. Flush both the hot and cold pipework
thoroughly to remove any debris.
14. Fit the inlet lters into the pipes.
Important! Make sure the backplate is vertical.
Inlet Filter
18
Page 19
15. Align the mixer with the inlet pipes and push
on fully. Secure the mixer to the backplate, but
do not overtighten the screws.
Note! Make sure that the grubscrews are
engaged fully in the valve body grooves.
Make sure that the slot for removing the
concealing plate is at the bottom.
Concealing
Plate
ON
OFF
16. Perform an inlet leak test.
Turn the flow lever to the OFF position
and restore the water flow to each of the
inlets. Slowly turn the mixer ON so that a
small amount of water ows from the outlet
(make sure the water is able to drain to a waste
outlet or is caught in a receptacle e.g. bucket
or jug). Turn the mixer off and look for water
leaks around each of the inlets.
If a leak is detected check the following:
i. The supply pipework is 15mm copper BS
EN 1057
ii. The supply pipework must extend between
30 and 35mm from the finished wall
surface.
iii. The supply pipework must be supported to
aid valve assembly.
iv. The internal mixer seals are damaged/
missing. Contact Mira Customer Services.
(See ‘Customer Services’ on the back
cover for details.)
17.Clip the concealing plate onto the backplate.
19
Page 20
Installing the Riser Pipe and
Showerhead
1. Isolate the water supplies to prevent accidental
operation of the shower.
2. Assemble the riser pipe to the overhead arm
using the screw and 2.5mm hexagonal key
(supplied).
3. Use the riser pipe and overhead arm as a guide
to mark the position of the wall mounting screw
in line with the mixer.
4. Drill a 13mm diameter hole for the wall
mounting plug.
Caution! Avoid drilling into concealed
water pipes or electrical cables.
5. Fix the wall mounting using the plug and screw
supplied. Tighten the screw using a 5mm
hexagonal driver (not supplied).
6. Fit the riser pipe and overhead arm to the mixer
and the wall mounting.
7. Fit the spreader screw through the top of the
overhead arm using the 2mm hexagonal key
(supplied). Tighten the screw to secure the
overhead arm.
8. Fix the riser pipe to the mixer using the
grubscrew and 2.5mm hexagonal key
(supplied).
Wall
Mounting
Plug
Wall
Mounting
Metal Washer
Wall Mounting
Screw
Spreader
Screw
Riser Pipe
Overhead Arm
Mixer
Care required when assembling
to avoid product damage.
20
Page 21
9. Fit the showerhead to the overhead arm.
10. Restore the water supplies and test the shower
functions correctly (see ‘Operation’). Check
for leaks from all connections.
Important! If required, t the ow regulator
supplied.
Flow
Regulator
11. If the maximum showering temperature requires
adjustment, refer to ‘Commissioning’.
12. Having completed the installation, make sure
that the user is familiar with the operation of
the shower.
21
Page 22
COMMISSIONING
Maximum Temperature Setting
Before using the shower, it is important to check
the maximum showering temperature is at a
safe level. The temperature has been preset
to approximately 45°C at the factory, but due
to variations in site conditions this may need
adjustment.
Note! Make sure that the hot water temperature
is at least 60°C and that there is sufcient supply.
Mira Calibre EV
1. Turn the shower on to full ow (lower lever turn
fully to the left).
Turn the temperature to full hot (upper lever
turn fully to the right) and allow the water
temperature to stabilise.
If the temperature is too hot or too cold adjust
as follows:
3. Turn the shower off and remove the handset
from the clamp bracket.
4. Remove the spreader screw from the top of
the slide bar and remove the slide bar from
the wall.
2. Check the showering temperature.
+
_
Care required when disassembling
to avoid product damage.
22
Page 23
5. Turn the temperature lever to mid blend and
disassemble as shown.
ColderHotter
1 notch = approx 1 - 1.5°C change
6. Lift the lever and stopper. Reposition the lever
by one notch.
Stopper
7. Turn the shower on and check the temperature
at full hot.
8. Repeat the adjustment as required until the
desired temperature is reached.
9. Reassemble the slide bar and ret the handset.
Do not force any parts when
reassembling. Make sure all
parts are aligned correctly.
23
Page 24
Mira Calibre ER
1. Turn the shower on to full ow (upper lever
turn fully to the right).
2. Turn the temperature to full hot (lower lever
turn fully to the left) and allow the water
temperature to stabilise.
3. Check the showering temperature.
+
If the temperature is too hot or too cold adjust
as follows:
4. Turn the shower off and turn the temperature
lever to mid blend, then disassemble as
shown.
_
O Seal
Lever
StopperTemperature
24
Page 25
5. Reposition the lever by one notch
Colder
View from underside
Hotter
1 notch = approx 1 - 1.5°C change
6. Turn the shower on and check the temperature
at full hot.
7. Repeat the adjustment as required until the
desired temperature is reached.
Do not force any parts when
reassembling. Make sure all
parts are aligned correctly.
25
Page 26
OPERATION
Mira Calibre EV
Cold
On
Height Adjustment
The height of the showerhead is easily adjusted
by moving the clamp bracket either up or down
the slide bar.
Hot
Temperature
Control
Off
Flow Control
26
Page 27
Changing the Spray Setting
The Mira 360 Showerhead has four different spray actions:- Rain, Burst, Storm and Cloud. The showerhead
features a rotating head to enable differing spray patterns to be achieved, turn the showerhead in the
direction shown to activate the different spray patterns.
1
Rain
2
4
CloudBurst
3
Storm
27
Page 28
Mira Calibre ER
Off
Hot
Showerhead Adjustment
The tilt angle of the showerhead can be adjusted
to suit the user.
On
Flow Control
Cold
Temperature
Control
28
Page 29
USER MAINTENANCE
If you require a Mira trained service engineer or
agent (see ‘Customer Services’ on the back
cover of this guide).
Fault Diagnosis
Symptom:
Only hot or cold water from the shower.
•
Shower temperature too hot or too cold.
•
Cause/Rectication:
Inlets reversed (hot supply to cold inlet).
•
Supply pipework requires rework.
Check the lters for any blockage.
•
Caution! After installation, the inlet lters
•
can only be accessed by disassembling the
product. This should only be attempted by a
competent tradesperson.
Water Supply conditions outside operating
•
parameters, (see ‘Specications’).
No hot water reaching the mixer.
•
If the temperature is too cold and you
have a combination type boiler it may
differentials are sufficient, (see
‘Specications’).
Flow regulator tted incorrectly.
•
Air lock or partial blockage in the pipework.
•
—————————————
Symptom:
Water leaking from showerhead after shower
•
is shut off.
Cause/Rectication:
Water dripping is normal for a short period
•
after shut off.
Check that the pressures are not in excess of
•
the specications for the product.
Renew the ow control assembly (see ‘Spare
•
Parts’)
Lubricants
Only use silicone based lubricants to reassemble
any rubber seals. Oil based or other lubricant
types may cause rapid deterioration of seals and
lead to product failure.
Cleaning
The chrome plated parts should be cleaned using
a mild washing up detergent or soap solution,
rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain
abrasive and chemical substances, and should
not be used for cleaning plated or plastic ttings.
These nishes should be cleaned with a mild
washing up detergent or soap solution, and then
wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any
limescale from the soft nozzles and the front
surface of the showerhead spray plate.
Do not use descalents on this product.
Spray Plate
Use your thumb or a soft cloth to wipe any
limescale from the soft rubber nozzles and
the front face of the spray plate assembly
Important! The sprayplate must be regularly
cleaned to make sure that the showerhead does
not become blocked.
Use your thumb or a soft cloth
to wipe any limescale from the
soft nozzles.
29
Page 30
SPARE PARTS
Mira Calibre EV
1678.342
A
1678.371
1678.339
x2
x2
1678.338
x2
x2
A
1678.340
1678.341
(can be congured as
EV or ER, does not
include lters or collets)
1678.338 Backplate
1678.339 Filter Pack
1678.340 Collet Pack
1678.341 Valve
1678.342 Flow Control Assembly
1678.343 Flow Lever Assembly
1678.344 Temperature Lever Assembly
1678.350 Component Pack (components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.371 Concealing Plate
x2
x2
1678.342
30
B
x2
1678.344
x2
B
1678.343
Page 31
Mira Calibre EV
A
A
1678.372
1678.349
1678.347
1678.345
1678.345 Slidebar
1678.347 Clamp Bracket
1678.348 Hose
1678.349 Handset
1678.350 Component Pack (components ‘A’)
1678.372 Large Wall Mount Accessory
1678.348
31
Page 32
Mira Calibre ER
1678.342
A
1678.338
x2
x2
x2
A
1678.339
1678.371
x2
1678.340
1678.341
1678.342
x2
x2
1678.341
1678.374
B
B
1678.343
x2
B
x2
B
1678.344
1678.341
(can be congured as
EV or ER, does not
include lters or collets)
1678.338 Backplate
1678.339 Filter Pack
1678.340 Collet Pack
1678.341 Valve
1678.342 Flow Control Assembly
1678.343 Flow Lever Assembly
1678.344 Temperature Lever Assembly
1678.350 Component Pack(components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.371 Concealing Plate
1678.374 Temperature Lever Cap
32
Page 33
Mira Calibre ER
A
1678.372
A
1678.352
B
A
1740.506
1678.351
A
1678.350 Component Pack
1678.351 Riser Pipe
1678.352 Overhead Arm
1678.350 Component Pack(components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.372Large Wall Mount Accessory
1740.506 Showerhead
33
Page 34
NOTES
34
Page 35
NOTES
35
Page 36
CUSTOMER SERVICE
Guarantee
Your product has the benefit of our manufacturer’s
guarantee which starts from the date of purchase.
To activate this guarantee, please return your completed
registration card, visit our website or free phone 0800
0731248 within 30 days of purchase (UK only).
Within the guarantee period we will resolve defects in
materials or workmanship, free of charge, by repairing or
replacing parts or product as we may choose.
This guarantee is in addition to your statutory rights
and is subject to the following conditions:
● The guarantee applies solely to he original installation
under normal use and to the original purchaser only.
The product must be installed and maintained in
accordance with the instructions given in this user
guide.
● Servicing must only be undertaken by us or our
appointed representative. Note! if a service visit
is required the product must be fully installed and
connected to services.
● Repair under this guarantee does not extend the original
expiry date. The guarantee on any replacement
parts or product ends at the original expiry date.
● For shower ttings or consumable items we reserve
the right to supply replacement parts only.
The guarantee does not cover:
● Call out charges for non product faults (such as
damage or performance issues arising from incorrect
installation, improper use, inappropriate cleaning,
lack of maintenance, build up of limescale, frost
damage, corrosion, system debris or blocked lters)
or where no fault has been found with the product.
● Water or electrical supply, waste and isolation issues.
● Compensation for loss of use of the product or
consequential loss of any kind.
● Damage or defects caused if the product is repaired
or modi ed by persons not authorised by us or our
appointed representative.
● Routine maintenance or replacement parts to
comply with the requirements of the TMV 2 or TMV
3 healthcare schemes.
● Accidental or wilful damage.
● Products purchased ex-showroom display.
Helpdesk Service - Ring our Customer
Services Team for product advice, to purchase
spare parts or accessories or to set up service
visit. You can contact us via phone or e-mail,
details below. Please provide your model
name, power rating (if applicable) and date
of purchase.
Mira Showers Website (www.mirashowers.
co.uk)
Visit our website to register your guarantee,
download user guides, diagnose faults,
purchase our full range of accessories and
popular spares, or request a service visit.
Spares and Accessories - We hold the largest
stocks of genuine Mira spares and accessories.
Contact us for a price or visit our website to
purchase items from our accessory range and
popular spares
Service/Repairs - No one knows our products
better than our nationwide team of Service
Technicians. We can carry out service or repair
work to your product both during and after the
guarantee period. Ask about our xed price
service repairs.
.
To Contact Us: UK
08445715000
Fax: 01 242 282595
E-mail: Visit www.mirashowers.co.uk/
contactus
Mira Customer Services Dept, Cromwell
Road, Cheltenham, Gloucestershire, GL52
5EP
To Contact Us: Eire Only
01 459 1344
What to do if something goes wrong
If your product does not work correctly refer to this
manual for fault diagnosis and check that it is installed
and commissioned in accordance with our instructions.
If this does not resolve the issue, contact us for help
and advice.
Extended Guarantees
A selection of protection plans are available that
enable you to cover repair bills (excludes Eire). Ring
01922 471763 for more details.