Kohler Mira Calibre Installation Manual

Page 1
Mira Calibre Thermostatic Shower
These instructions must be left with the user
Installation Guide
For SPARES, ADVICE
or REPAIRS
Please call us on
0844 571 5000
(UK Only)
Page 2
CONTENTS
Introduction 3
Guarantee 3
Recommended Usage 3
Patents and Design Registration 3
Safety Warnings 4 Pack Contents 5
Mira Calibre EV 5
Mira Calibre ER 6
Specications 7
Pressures 7
Temperatures 7
Thermostatic Shut-down 7
Connections 7
Dimensions 8
Installation 9
Suitable Plumbing Systems 9
General 9
Mira Calibre EV Installing the Shower Mixer 10
Installing the Slide Bar and Shower Handset 14
Mira Calibre ER Installing the Shower Mixer 16
Installing the Riser Pipe and Showerhead 20
Commissioning 22 Maximum Temperature Setting 22
Mira Calibre EV 22
Mira Calibre ER 24
Operation 26
Mira Calibre EV 26
Height Adjustment 26
Changing the Spray Setting 27
Mira Calibre ER 28
Showerhead Adjustment 28
User Maintenance 29
Fault Diagnosis 29
Lubricants 29
Cleaning 29
Spray Plate 29
Spare Parts 30
Mira Calibre EV 30
Mira Calibre ER 32
Customer Service 36
If you experience any difficulty with the installation or operation of your new thermostatic mixer, please refer to ‘Fault Diagnosis’ before contacting Mira Showers. Our contact details can be found on the back cover of this guide.
Page 3
INTRODUCTION
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
The Mira Cal bre EV is a thermostatic mixing shower with integral slidebar, hose and Mira 360 shower handset.
The Mira Calibre ER is a thermostatic mixing
shower with integral riser rail and xed height
250mm showerhead attached with a ball joint.
The thermostatic mixing valve incorporates a temperature sensing unit, which provides an almost immediate response to changes in water temperature or pressure to maintain a comfortable shower. An adjustable maximum temperature stop is provided to limit the showering temperature to a preset level. This is a safety feature that can be adjusted after installation (see “Commissioning”
for further details) Inlet water lters are tted to
protect the internal mechanism.
Recommended Usage
Application Valve with Fittings
Domestic
Light Commercial
Heavy Commercial
Healthcare
ü
ü
û
û
Patents and Design Registration
Patents:
GB 2 422 886
Patent Applications:
Europe 07015846.4
USA 2010-0219255-A1
Products manufactured by us are safe and risk-free, provided they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.
Guarantee
For domestic installations, Mira Showers guarantee the Mira Calibre Thermostatic Mixer against any defect in materials or workmanship for a period of ve years from the date of purchase.
The shower handset, hose and clamp bracket supplied with the Mira Cal bre EV model are guaranteed for one year from date of purchase.
The showerhead supplied with the Mira Cal bre ER model is guaranteed for one year from date of purchase.
For terms and conditions refer to ‘Customer Services’ on the back cover of this guide.
Design Registration:
001240527 - 0002 001240527 - 0004 001312649 - 0014 001004022
Page 4
SAFETY WARNINGS
WARNING - This product can deliver scalding temperatures if not installed, operated or maintained in accordance with the instructions, warnings and cautions contained in this guide.
The function of a thermostatic mixing valve is to deliver water consistently at a safe temperature. In keeping with every other mechanism, it cannot be considered as functionally infall ble and as such, cannot totally replace a supervisor’s vigilance where that is necessary. Provided it is installed, commissioned, operated and maintained within manufacturers recommendations, the risk of failure, if not eliminated, is reduced to the minimum achievable.
Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided:
1. They are installed, commissioned, operated
and maintained in accordance with the manufacturer’s recommendations.
2. Periodic attention is given, when necessary, to
maintain the product in good functional order.
Caution!
1. Read all of these instructions.
2. Retain this guide for later use.
3. Installation must be carried out in accordance
with these instructions, and must be conducted by designated, qualified and competent personnel.
4. Provision must be made to prevent water
ingress back into the wall structure.
5. DO NOT fit the product where it may be exposed to freezing conditions. DO NOT operate this appliance if it is frozen. Allow the appliance to thaw and check for leaks before using.
6. Make sure that any pipework that could become frozen is properly insulated.
7. DO NOT overtighten grubscrews as product damage may occur. Use hexagonal key provided and hand tighten only, DO NOT use power tools.
8. All pipework must be checked for leaks before the product installation is completed. The product should be pressurised and the inlet and outlet connections inspected.
9. Pass on this guide in the event of change of ownership of the product.
10. Follow all warnings, cautions and instructions contained in this guide.
11. Make sure that you fully understand how
to operate this shower before use, read all operating instructions and retain this guide for future reference.
12. Care is required when adjusting flow or
temperature. Make sure that the temperature has stabilised before use.
13. This product is not intended for use by
persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety.
14.
Children should be supervised to ensure that
they do not play with the product.
15. DO NOT perform any unspecied modications
to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts.
16. If the shower is dismantled during installation
or servicing then upon completion the product must be inspected to ensure all connections are tight and that there are no leaks.
17.Only Mira recommended outlet ttings should
be used.
18. Sunburn or skin conditions can increase your
sensitivity to hot water. Make sure that you set the shower to a cooler temperature.
19. The water supplies to this product must be
isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.
20. When this product has reached the end of its
serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
Page 5
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre EV
q 1 x Thermostatic Mixer
q 1 x Slide Bar
q 1 x Shower Handset
q 2 x Rubber Washer
q 1 x Clamp Bracket
q 1 x Shower Hose
q 1 x 2.5mm
Hexagonal Key
1 x 2mm
q
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
Page 6
PACK CONTENTS
Conrm that all of the parts are included.
Mira Calibre ER
q 1 x Thermostatic Mixer
q 1 x Overhead Arm
q 1 x Showerhead
q 1 x Riser Pipe
q 1 x 2.5mm
Hexagonal Key
q 1 x 2mm
Hexagonal Key
q 2 x Grubscrew
q 1 x Spreader Screw
q 1 x Washer
q 1 x 12 l/min Flow Regulator
q 2 x J G Collet
q 2 x Filter
q 1 x Wall Mounting
q 4 x Wall Screw No. 8 x 1¼”
q 4 x Wall Plug
q 1 x Wall Mounting Screw
q 1 x Wall Mounting Plug
Documentation
q 1 x Guarantee Registration Document
Page 7
SPECIFICATIONS
Pressures
Max Static Pressure: 10 Bar.
•
Max Maintained Pressure: 5 Bar.
•
Min Maintained Pressure (Gravity System):
•
0.5 Bar (0.5 bar = 5 Metre head from cold tank outlet to showerhead).
For optimum performance supplies should be
•
at nominally equal pressure.
Temperatures
Factory Pre-set (Max Blend) Shower: 45°C
•
(can be altered after installation if required). Optimum Thermostatic Control Range: 35°C
•
to 45°C achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures.
Recommended Hot Supply: 60°C to 65°C
•
Note! For safety and performance reasons it is recommended that the maximum hot water temperature should not exceed 65°C.
Cold Water Range: up to 25°C.
•
Minimum Recommended Differential between
•
Hot Supply and Outlet Temperature: 12°C.
Thermostatic Shut-down
For safety, the thermostat will shut off the
•
mixing valve within 2 seconds if either supply fails (achieved only if the blend temperature has a minimum differential of 12°C from either inlet supply).
Connections
The thermostatic mixer can only be installed with rear supply inlets and the supply pipework must be connected as shown.
Inlets: Pushfit 15mm Copper pipe to
•
•
Caution! This product does not allow for
reversed inlets and will not function if
ttedincorrectly.
Do not use plastic pipe with this
product.Theltersmustbettedand
are only suitable for 15mm copper
BS EN 1057.
Not suitable for 14.7mm copper
pipe manufactured in Éire!
Outlets: ½” BSP at face to hose and handset.
½” BSP at face to showerhead.
pipework.
Mira Calibre EV
Cold
Mira Calibre ER
Hot
Hot
Outlet
Outlet
Cold
Page 8
Dimensions
Mira Calibre ERMira Calibre EV
362
71
250
925 max.
910
59
59
200
145
IMPORTANT!
The Slide Bar and Riser Pipe MUST NOT be cut or extended to adjust the height. The above dimensions are to be adhered to.
145
200
All dimensions in mm
Page 9
INSTALLATION
Suitable Plumbing Systems
Mains Pressurised Instantaneous Hot Water System (Combination Boiler):
The product can be installed with systems of this type with balanced pressures. (Recommended Minimum Maintained Pressure: 0.5 Bar).
Unvented Mains Pressure System:
The product can be installed with an unvented, stored hot water system.
Pumped System:
The product can be installed with an inlet pump (twin impeller). The pump must be installed in a suitable location and in accordance with its instructions.
Gravity System:
The product can be installed on a gravity head system with a minimum head of 5m (0.5 bar), measured from the cold water tank outlet to the showerhead when installed (ER) or from the cold water tank outlet to the shower handset at the highest position when installed (EV).
General
The installation must be carried out in accordance with these instructions, and must be conducted by
designated, qualied and competent personnel.
The installation must comply with the ‘Water Supply Regulations 1999 (Water Fittings)’ or
any particular regulations and practices, specied
by the local water company or water undertakers.
Note!
The product includes checkvalves tted to the
mixer inlets and shower handset (EV). Make sure that all site requirements correspond to
the information given in ‘Specications’.
and avoid any strain on the connections.
5. Hidden pipework dead-legs should be kept to
a minimum.
6. Decide on a suitable position for the Mixer,
make sure that there is sufcient headroom
and ceiling clearance to install the integral slidebar and showerhead.
Avoid positioning the wall mounting between
tiles. The xing is strongest in the centre of a
tile.
7. The inlet pipework must be ushed thoroughly before tting the mixer.
8. Upon completion of the installation, the product must be checked to make sure there are no leaks.
1. The thermostatic mixer must not be installed
in an area where it may freeze.
2. For stud partitions alternative xings may be
required (not supplied).
3. Isolating valves must be installed as close
to the thermostatic mixer as reasonably practicable for ease of maintenance.
4. Hidden pipework must be rigidly supported
Page 10
Mira Calibre EV Installing the Shower Mixer
1. The mixer must be tted vertically as illustrated
and can only be installed with rear supply inlets.
2. Determine the route for the hot and cold supply
pipework.
Note! Make sure that there is sufcient ceiling
clearance to install the integral slidebar. (Minimum of 110cm from ceiling to the centre of upper inlet.)
3. Remove the backplate from the mixer by loosening the two grubscrews with the 2.5mm hexagonal key supplied.
Backplate
Cold
Cold to the Upper Inlet
•
Hot to the Lower Inlet
•
Bottom Outlet
•
Hot
4. Using the backplate as a guide, mark the
positions of the pipe centres.
110cm minimum from ceiling
Outlet
10
Page 11
5. Install the supply pipework. Make allowance
for the pipework to extend a minimum of 50mm
from the nished wall surface (the pipework will
be trimmed back later).
IMPORTANT! support pipework from rear to aid valve assembly
Panel / Partition Wall
Solid Wall
50mm minimum from
nished wall
Noggin for slide bar wall mounting
6. Finish the wall surface to cover the pipework.
7. Using an appropriate pipe cutter, trim the protruding pipework back to 30 - 35mm.
8. Remove all burrs and sharp edges from the pipework.
30 - 35mm
Noggin for pipework
9. Fit the backplate over the pipes and mark the
xing holes.
10. Remove the backplate and drill the holes. For solid walls use a 6mm drill for the wall plugs supplied. For other types of wall structure alternative fixings may be required (not supplied).
Channels cut for pipework
11
Page 12
11. Ret the backplate and secure to the wall using
the wallplugs and xing screws (supplied).
12. Fit the collets onto the inlet pipework. Make sure the surfaces of the inlet pipes are clean and free from debris e.g dried plaster or grout.
Collet
13. Flush both the hot and cold pipework thoroughly to remove any debris.
14. Fit the inlet lters into the pipes.
Important! Make sure the backplate is vertical.
Inlet Filter
12
Page 13
15. Align the mixer with the inlet pipes and push
on fully. Secure the mixer to the backplate, but do not overtighten the grubscrews.
Note! Make sure that the grubscrews are engaged fully in the valve body grooves.
Make sure that the slot for removing the concealing plate is at the bottom.
Concealing Plate
OFF
ON
16. Perform an inlet leak test.
Turn the flow lever to the OFF position and restore the water flow to each of the inlets. Slowly turn the mixer ON so that a small amount of water ows from the outlet (make sure the water is able to drain to a waste outlet or is caught in a receptacle e.g. bucket or jug). Turn the mixer off and look for water leaks around each of the inlets.
If a leak is detected check the following: i. The supply pipework is 15mm copper BS
EN 1057
ii. The supply pipework must extend between
30 and 35mm from the finished wall surface.
iii. The supply pipework must be supported to
aid valve assembly.
iv. The internal mixer seals are damaged/
missing. Contact Mira Customer Services. (See ‘Customer Services’ on the back cover for details.)
17.Clip the concealing plate onto the backplate.
13
Page 14
Installing the Slide Bar and Shower Handset
1. Isolate the water supplies to prevent accidental
operation of the shower.
2. Assemble the clamp bracket onto the slide bar.
3. Use the slide bar as a guide to mark the
position of the wall mounting screw in line with the mixer.
4. Drill a 13mm diameter hole for the wall
mounting plug.
Caution! Avoid drilling into concealed water pipes or electrical cables.
5. Fix the wall mounting using the plug and screw
supplied. Tighten the screw using a 5mm hexagonal driver (not supplied).
6. Fit the slidebar to the mixer and the wall
mounting.
7. Fit the spreader screw through the top of the slide bar using the 2mm hexagonal key (supplied).
Wall Mounting Plug
Wall Mounting
Metal Washer
Wall Mounting Screw
Spreader Screw
Clamp Bracket
TOP
Mixer
Care required when assembling to avoid product damage.
continued...
14
Page 15
8. Fit the hose and shower handset. Note! The hose is supplied with a straight
end and a tapered end. Fit the tapered end to
the shower handset. Be sure to t the rubber
washers to both ends of the hose.
Rubber Washer
Rubber Washer
Straight
9. Restore the water supplies and test the shower
functions correctly (see ‘Operation’). Check for leaks from all connections.
10. Important! If required, t the ow regulator
supplied.
11. If the maximum showering temperature requires
adjustment, refer to ‘Commissioning’.
12. Having completed the installation, make sure
that the user is familiar with the operation of the shower.
Tapered
Flow Regulator
15
Page 16
Mira Calibre ER Installing the Shower Mixer
1. The thermostatic mixer must be tted vertically
as illustrated and can only be installed with rear supply inlets.
2. Determine the route for the hot and cold supply pipework.
Note! Make sure that there is sufficient ceiling clearance to install the riser pipe and showerhead. (Minimum of 110 centimetres from ceiling to the centre of upper inlet.)
Outlet
3. Remove the backplate away from the mixer.
Backplate
Hot
Hot to the Upper Inlet
•
Cold to the Lower Inlet
•
Top Outlet
•
Cold
4. Using the backplate as a guide, mark the
positions of the pipe centres.
110cm minimum from ceiling
16
Page 17
5. Install the supply pipework. Make allowance for the pipework to extend a minimum of 50mm
from the nished wall surface (the pipework will
be trimmed back later).
Panel / Partition Wall
Noggin for overhead arm wall mounting
Noggin for pipework
Solid Wall
IMPORTANT! support pipework from rear to aid valve assembly
50mm minimum from
nished wall
6. Finish the wall surface to cover the pipework.
7. Using an appropriate pipe cutter, trim the protruding pipework back to 30 - 35mm.
8. Remove all burrs and sharp edges from the pipework.
30 - 35mm
9. Fit the backplate over the pipes and mark the
xing holes.
10. Remove the backplate and drill the holes. For solid walls use a 6mm drill for the wall plugs supplied. For other types of wall structure alternative fixings may be required (not supplied).
Channels cut for pipework
17
Page 18
11. Ret the backplate and secure to the wall using
the wallplugs and xing screws (supplied).
12. Fit the collets onto the inlet pipework. Make sure the surfaces of the inlet pipes are clean and free from debris e.g dried plaster or grout.
Collet
13. Flush both the hot and cold pipework thoroughly to remove any debris.
14. Fit the inlet lters into the pipes.
Important! Make sure the backplate is vertical.
Inlet Filter
18
Page 19
15. Align the mixer with the inlet pipes and push
on fully. Secure the mixer to the backplate, but do not overtighten the screws.
Note! Make sure that the grubscrews are engaged fully in the valve body grooves.
Make sure that the slot for removing the concealing plate is at the bottom.
Concealing Plate
ON
OFF
16. Perform an inlet leak test.
Turn the flow lever to the OFF position and restore the water flow to each of the inlets. Slowly turn the mixer ON so that a small amount of water ows from the outlet (make sure the water is able to drain to a waste outlet or is caught in a receptacle e.g. bucket or jug). Turn the mixer off and look for water leaks around each of the inlets.
If a leak is detected check the following: i. The supply pipework is 15mm copper BS
EN 1057
ii. The supply pipework must extend between
30 and 35mm from the finished wall surface.
iii. The supply pipework must be supported to
aid valve assembly.
iv. The internal mixer seals are damaged/
missing. Contact Mira Customer Services. (See ‘Customer Services’ on the back cover for details.)
17.Clip the concealing plate onto the backplate.
19
Page 20
Installing the Riser Pipe and Showerhead
1. Isolate the water supplies to prevent accidental
operation of the shower.
2. Assemble the riser pipe to the overhead arm
using the screw and 2.5mm hexagonal key (supplied).
3. Use the riser pipe and overhead arm as a guide
to mark the position of the wall mounting screw in line with the mixer.
4. Drill a 13mm diameter hole for the wall
mounting plug.
Caution! Avoid drilling into concealed water pipes or electrical cables.
5. Fix the wall mounting using the plug and screw
supplied. Tighten the screw using a 5mm hexagonal driver (not supplied).
6. Fit the riser pipe and overhead arm to the mixer
and the wall mounting.
7. Fit the spreader screw through the top of the
overhead arm using the 2mm hexagonal key
(supplied). Tighten the screw to secure the overhead arm.
8. Fix the riser pipe to the mixer using the grubscrew and 2.5mm hexagonal key (supplied).
Wall Mounting Plug
Wall Mounting
Metal Washer
Wall Mounting Screw
Spreader Screw
Riser Pipe
Overhead Arm
Mixer
Care required when assembling to avoid product damage.
20
Page 21
9. Fit the showerhead to the overhead arm.
10. Restore the water supplies and test the shower
functions correctly (see ‘Operation’). Check for leaks from all connections.
Important! If required, t the ow regulator
supplied.
Flow Regulator
11. If the maximum showering temperature requires adjustment, refer to ‘Commissioning’.
12. Having completed the installation, make sure that the user is familiar with the operation of the shower.
21
Page 22
COMMISSIONING
Maximum Temperature Setting
Before using the shower, it is important to check the maximum showering temperature is at a safe level. The temperature has been preset to approximately 45°C at the factory, but due to variations in site conditions this may need adjustment.
Note! Make sure that the hot water temperature
is at least 60°C and that there is sufcient supply.
Mira Calibre EV
1. Turn the shower on to full ow (lower lever turn
fully to the left). Turn the temperature to full hot (upper lever
turn fully to the right) and allow the water temperature to stabilise.
If the temperature is too hot or too cold adjust as follows:
3. Turn the shower off and remove the handset
from the clamp bracket.
4. Remove the spreader screw from the top of
the slide bar and remove the slide bar from the wall.
2. Check the showering temperature.
+
_
Care required when disassembling to avoid product damage.
22
Page 23
5. Turn the temperature lever to mid blend and disassemble as shown.
ColderHotter
1 notch = approx 1 - 1.5°C change
6. Lift the lever and stopper. Reposition the lever
by one notch.
Stopper
7. Turn the shower on and check the temperature at full hot.
8. Repeat the adjustment as required until the desired temperature is reached.
9. Reassemble the slide bar and ret the handset.
Do not force any parts when reassembling. Make sure all parts are aligned correctly.
23
Page 24
Mira Calibre ER
1. Turn the shower on to full ow (upper lever
turn fully to the right).
2. Turn the temperature to full hot (lower lever
turn fully to the left) and allow the water temperature to stabilise.
3. Check the showering temperature.
+
If the temperature is too hot or too cold adjust as follows:
4. Turn the shower off and turn the temperature lever to mid blend, then disassemble as shown.
_
O Seal
Lever
StopperTemperature
24
Page 25
5. Reposition the lever by one notch
Colder
View from underside
Hotter
1 notch = approx 1 - 1.5°C change
6. Turn the shower on and check the temperature
at full hot.
7. Repeat the adjustment as required until the desired temperature is reached.
Do not force any parts when reassembling. Make sure all parts are aligned correctly.
25
Page 26
OPERATION
Mira Calibre EV
Cold
On
Height Adjustment
The height of the showerhead is easily adjusted by moving the clamp bracket either up or down the slide bar.
Hot
Temperature
Control
Off
Flow Control
26
Page 27
Changing the Spray Setting
The Mira 360 Showerhead has four different spray actions:- Rain, Burst, Storm and Cloud. The showerhead features a rotating head to enable differing spray patterns to be achieved, turn the showerhead in the
direction shown to activate the different spray patterns.
1
Rain
2
4
Cloud Burst
3
Storm
27
Page 28
Mira Calibre ER
Off
Hot
Showerhead Adjustment
The tilt angle of the showerhead can be adjusted
to suit the user.
On
Flow Control
Cold
Temperature
Control
28
Page 29
USER MAINTENANCE
If you require a Mira trained service engineer or agent (see ‘Customer Services’ on the back cover of this guide).
Fault Diagnosis
Symptom:
Only hot or cold water from the shower.
•
Shower temperature too hot or too cold.
•
Cause/Rectication:
Inlets reversed (hot supply to cold inlet).
•
Supply pipework requires rework.
Check the lters for any blockage.
•
Caution! After installation, the inlet lters
•
can only be accessed by disassembling the product. This should only be attempted by a
competent tradesperson.
Water Supply conditions outside operating
•
parameters, (see ‘Specications’).
No hot water reaching the mixer.
•
If the temperature is too cold and you have a combination type boiler it may
notbeproducingsufcientlyhotwaterat required ow rate (see ‘Specications’).
Fit flow regulator supplied (see ‘Installation’).
—————————————
Symptom:
Fluctuating or reduced ow rate.
•
Cause/Rectication:
Check the showerhead, hose and lters for
•
any blockage.
Make sure that the maintained inlet pressures
•
are nominally balanced and sufcient, (see
‘Specications’).
Make sure that the inlet temperature
•
differentials are sufficient, (see ‘Specications’).
Flow regulator tted incorrectly.
•
Air lock or partial blockage in the pipework.
•
—————————————
Symptom:
Water leaking from showerhead after shower
•
is shut off.
Cause/Rectication:
Water dripping is normal for a short period
•
after shut off.
Check that the pressures are not in excess of
•
the specications for the product.
Renew the ow control assembly (see ‘Spare
•
Parts’)
Lubricants
Only use silicone based lubricants to reassemble any rubber seals. Oil based or other lubricant types may cause rapid deterioration of seals and lead to product failure.
Cleaning
The chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth.
Warning! Many household cleaners contain abrasive and chemical substances, and should
not be used for cleaning plated or plastic ttings. These nishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the showerhead spray plate.
Do not use descalents on this product. Spray Plate
Use your thumb or a soft cloth to wipe any limescale from the soft rubber nozzles and the front face of the spray plate assembly
Important! The sprayplate must be regularly
cleaned to make sure that the showerhead does not become blocked.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles.
29
Page 30
SPARE PARTS
Mira Calibre EV
1678.342
A
1678.371
1678.339
x2
x2
1678.338
x2
x2
A
1678.340
1678.341
(can be congured as
EV or ER, does not
include lters or collets)
1678.338 Backplate
1678.339 Filter Pack
1678.340 Collet Pack
1678.341 Valve
1678.342 Flow Control Assembly
1678.343 Flow Lever Assembly
1678.344 Temperature Lever Assembly
1678.350 Component Pack (components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.371 Concealing Plate
x2
x2
1678.342
30
B
x2
1678.344
x2
B
1678.343
Page 31
Mira Calibre EV
A
A
1678.372
1678.349
1678.347
1678.345
1678.345 Slidebar
1678.347 Clamp Bracket
1678.348 Hose
1678.349 Handset
1678.350 Component Pack (components ‘A’)
1678.372 Large Wall Mount Accessory
1678.348
31
Page 32
Mira Calibre ER
1678.342
A
1678.338
x2
x2
x2
A
1678.339
1678.371
x2
1678.340
1678.341
1678.342
x2
x2
1678.341
1678.374
B
B
1678.343
x2
B
x2
B
1678.344
1678.341
(can be congured as
EV or ER, does not
include lters or collets)
1678.338 Backplate
1678.339 Filter Pack
1678.340 Collet Pack
1678.341 Valve
1678.342 Flow Control Assembly
1678.343 Flow Lever Assembly
1678.344 Temperature Lever Assembly
1678.350 Component Pack (components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.371 Concealing Plate
1678.374 Temperature Lever Cap
32
Page 33
Mira Calibre ER
A
1678.372
A
1678.352
B
A
1740.506
1678.351
A
1678.350 Component Pack
1678.351 Riser Pipe
1678.352 Overhead Arm
1678.350 Component Pack (components ‘A’)
1678.354 Seal Pack (components ‘B’)
1678.372 Large Wall Mount Accessory
1740.506 Showerhead
33
Page 34
NOTES
34
Page 35
NOTES
35
Page 36
CUSTOMER SERVICE
Guarantee
Your product has the benefit of our manufacturer’s guarantee which starts from the date of purchase. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only).
Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose.
This guarantee is in addition to your statutory rights and is subject to the following conditions:
● The guarantee applies solely to he original installation
under normal use and to the original purchaser only. The product must be installed and maintained in accordance with the instructions given in this user guide.
● Servicing must only be undertaken by us or our
appointed representative. Note! if a service visit is required the product must be fully installed and connected to services.
● Repair under this guarantee does not extend the original
expiry date. The guarantee on any replacement parts or product ends at the original expiry date.
● For shower  ttings or consumable items we reserve
the right to supply replacement parts only.
The guarantee does not cover:
● Call out charges for non product faults (such as
damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost
damage, corrosion, system debris or blocked  lters)
or where no fault has been found with the product.
● Water or electrical supply, waste and isolation issues.
● Compensation for loss of use of the product or
consequential loss of any kind.
● Damage or defects caused if the product is repaired or modi ed by persons not authorised by us or our
appointed representative.
● Routine maintenance or replacement parts to
comply with the requirements of the TMV 2 or TMV 3 healthcare schemes.
● Accidental or wilful damage.
● Products purchased ex-showroom display.
Helpdesk Service - Ring our Customer Services Team for product advice, to purchase spare parts or accessories or to set up service visit. You can contact us via phone or e-mail, details below. Please provide your model name, power rating (if applicable) and date
of purchase.
Mira Showers Website (www.mirashowers. co.uk)
Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and
popular spares, or request a service visit. Spares and Accessories - We hold the largest
stocks of genuine Mira spares and accessories. Contact us for a price or visit our website to purchase items from our accessory range and
popular spares Service/Repairs - No one knows our products
better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the
guarantee period. Ask about our  xed price
service repairs.
.
To Contact Us: UK
08445715000
Fax: 01 242 282595
E-mail: Visit www.mirashowers.co.uk/
contactus
Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
To Contact Us: Eire Only
01 459 1344
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions. If this does not resolve the issue, contact us for help and advice.
Extended Guarantees
A selection of protection plans are available that enable you to cover repair bills (excludes Eire). Ring 01922 471763 for more details.
Mira is a registered trade mark of
Kohler Mira Limited.
The company reserves the right to alter
product speci cations without notice.
1186331-W2-A (1678) (B95Ab/B95Ac) © Kohler Mira Limited, September 2012
Fax: Dublin 01 459 2329
E-mail: sales@modernplant.ie
Modern Plant Ltd (Dublin), Otter House, Naas Road, Clondalkin, Dublin 22
FM 14648
Loading...