Kohler Mira Beat User Manual

1327877-W2-A© Kohler Mira Limited, October 2017
635 mm
Mira Beat Shower Fittings
Installation & User Guide
These instructions must be left with the user
0844 571 5000
To Contact Us: UK
Calls cost 7p per minute plus your phone company’s access charge
www.mirashowers.co.uk - Full details of the manufacturer’s guarantee is available on the website.
Spare Parts
Cleaning and User Maintenance
De-scaling the Showerhead
Important! Keeping the showerhead clean and
free from limescale will ensure that your shower and showerhead continue to perform to their maximum. A blocked showerhead can restrict the
ow rate and may cause damage to your shower.
6 7
1740.616 (Multi Mode - White)
1740.615 (Multi Mode - Chrome)
Handset Assembly
632.73
Hose Seal (x2)
1703.202 (White)
1703.203 (Chrome)
Clamp Bracket
Assembly
1703.210
Shower Hose (1.25 m)
1603.104
Shower Hose (Metal)
1603.137
Shower Hose (Plastic)
1703.195
Taper Block
1264164
Slide Bar
1703.194
Mounting Pack
1740.595 (White)
1740.596 (Chrome)
Slide Bar Support (x2)
Use your thumb or a soft cloth to wipe any limescale from the nozzles
1703.197
Soap Dish
1703.196
Cap (x2)
Operation
Clamp Bracket Adjustment
1. Slide the Clamp Bracket up and down on the Slide Rail until the Showerhead is positioned to your preference.
Handset Installation
Handset
Assembly
Hose and Handset Installation
1. Fit a hose seal into the conical nut and screw
onto the outlet of the shower.
Caution! Do not over tighten.
2. Feed the hose through the soap dish.
3. Fit a hose seal into the conical nut and screw
onto the handset assembly.
Caution! Do not over tighten.
4. Place the handset assembly into the clamp bracket assembly.
1. Unscrew the hose from the showerhead and the shower outlet.
2. Inspect the hose.
3. Replace if necessary.
Inspecting the Hose
Important! The shower hose should be inspected
periodically for damage or internal collapse,
internal collapse can restrict the ow rate from the
showerhead and may cause damage to the shower.
1740.368 (Multi Mode - White)
1740.369 (Multi Mode - Chrome)
Handset Assembly
Zone of
Backflow
Risk
Soap Dish Fitted and Shower Fittings Fixed at a
Suitable Height Preventing Dirty Water Backow
30 mm
Min.
Bath or Shower
Tray FC3
Electric Shower
25 mm
Min.
25 mm Min.
Toilet or Bidet
FC5
Hand Basin
FC3
Note! There will be occasions when the soap dish will not provide a suitable solution for Fluid Category 3 installations. In these instances an outlet double
checkvalve must be tted, this will increase the
required supply pressure typically by 10 kPa (0.1 bar).
Double checkvalves tted in the inlet supply to the
appliance cause a pressure build up, which affects the maximum static inlet pressure for the appliance
and must not be tted. For Fluid Category 5, double
checkvalves are not suitable.
InstallationSpecications
1. Installation of the shower ttings must be carried
out in accordance with these instructions by
qualied, competent personnel.
2. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation
or practice specied by the local water supply
company.
3. Install the shower ttings over a water catchment
area and position so that the water discharges down the centre line of the bath, or across the opening of a shower cubicle. The handset should direct the water away from the shower unit.
4. DO NOT t any form of ow control in the outlet pipe work if the shower ttings are installed in conjunction with a product that requires the ttings
to act as a vent (e.g. an electric shower).
5. DO NOT use excessive force when making connections.
6. Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.
7. Special consideration should be given to the xing
arrangements when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative
proprietary cavity xings, or choose other options, however, these methods of xing are beyond the
scope of this guide.
8. The position of the shower ttings must provide a minimum air gap of 25 mm between the
showerhead and the spill over level of any bath, shower tray or basin. There must be a minimum
distance of 30 mm between the showerhead and
the spill over lever of any toilet, bidet or other
appliance with a Fluid Category 5 backow risk.
General
Minimum maintained water pressure
0.1 bar (10 kPa)
Maximum maintained water pressure
2.0 bar (500 kPa)
2 3 4 5
1. We recommend that the slide bar is installed with
the ends ush. Mark the wall xing positions and drill two holes to suit the wall xings.
Caution! Do not drill into cables or pipes in the
wall.
2. Fit the wall plugs and the mounting brackets and secure with the wall screws.
Note! Check for vertical alignment before
tightening. The mounting brackets are slotted to aid alignment. Then fully tighten.
3. Fit the clamp bracket (rotate the lever to help with the installation), the soap dish and the slide bar support to the slide bar.
4. Make sure that the wall screws are ush with the
inside edge of the mounting brackets.
5. Fit the slide bar supports over the mounting brackets, then adjust the slide bar vertically ensuring an equal length of slide bar protrudes from the top and bottom mounting bracket
(or ush with the end of the slide bar for new
installations).
6. Remove the slide bar assembly carefully, preventing any further movement between the slide bar and the slide bar supports.
7. Tighten the two slide bar clamping screws no more than half a turn to secure the slide bar supports to the slide bar.
Caution! Overtightening these screws will cause
damage.
8. Install the slide bar assembly onto the mounting brackets. Tighten the 2 x M4 screws with the supplied 3 mm hexagonal key.
Caution! Do not force assembly on to the
mounting brackets, re-align a slide bar support if required.
9. Install end cap at the top and soap dish at the bottom of the slide bar.
Clamp Bracket
Soap Dish
Slide Bar
Clamping Screw
Mounting
Bracket
End Cap
Slide Bar Support
Tighten slide bar clamping screw no more than 1/2 turn
Slide Bar