Kohler Mira 1799.001, Mira 1799.002, Mira 1799.003, Mira 1799.004, Mira 1799.005 Installation And User Manual

Mira Beat 200 mm Deluge Overhead (1799.001 - Chrome)
Mira Beat 200 mm Deluge Overhead (1799.002 - White)
Mira Beat 250 mm Deluge Overhead (1799.003 - Chrome)
Mira Beat 250 mm Deluge Overhead (1799.004 - White)
Mira Wall-fed Fixed Head Arm (1799.005)
These instructions must be left with the user
Installation and User Guide
1192072-W2-A
© Kohler Mira Limited, June 2012
Mira is a registered trade mark of
The company reserves the right to alter
product specifi cations without notice.
FM 14648
Guarantee
Your product has the benefit of our manufacturer’s guarantee which starts from the date of purchase. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only).
Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose.
This guarantee is in addition to your statutory rights and is subject to the following conditions:
● The guarantee applies solely to the original installation under normal use and to the original purchaser only. The product must be installed and maintained in accordance with the instructions given in this user guide.
● Servicing must only be undertaken by us or our appointed representative. Note! if a service visit is required the product must be fully installed and connected to services.
● Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date.
● For shower fi ttings or consumable items we reserve the right to supply replacement parts only.
The guarantee does not cover:
● Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product.
● Water or electrical supply, waste and isolation issues.
● Compensation for loss of use of the product or consequential loss of any kind.
● Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative.
● Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV
3 healthcare schemes.
● Accidental or wilful damage.
● Products purchased ex-showroom display.
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions. If this does not resolve the issue, contact us for help and advice.
Extended Guarantees
A selection of protection plans are available that enable you to cover repair bills (excludes Eire). Ring 01922 471763 for more details.
01 459 1344
Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
Helpdesk Service - Ring our Customer Services Team for product advice, to purchase spare parts or accessories or to set up service visit. You can contact us via phone or e-mail, details below. Please provide your model name, power rating (if applicable) and date of purchase.
Mira Showers Website (www.mirashowers. co.uk)
Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and popular spares, or request a service visit.
Spares and Accessories - We hold the largest stocks of genuine Mira spares and accessories. Contact us for a price or visit our website to purchase items from our accessory range and popular spares
.
Service/Repairs - No one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period. Ask about our fi xed price service repairs.
To Contact Us: UK
Fax: Dublin 01 459 2329
CUSTOMER SERVICE
E-mail: Visit www.mirashowers.co.uk/ contactus
To Contact Us: Eire Only
Modern Plant Ltd (Dublin), Otter House, Naas Road, Clondalkin, Dublin 22
0844 571 5000
Fax: 01 242 282595
E-mail: sales@modernplant.ie
INTRODUCTION
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
These shower ttings are designed to give a satisfactory
shower over a range of pressures between 0.1 and 5.0 bar.
1799.008
Mira Beat 250 mm Showerhead - Chrome
1799.007
Mira Beat 200 mm Showerhead - Chrome
1799.009
Shower Arm
1656.132
Concealing Shroud
SPARE PARTS
MAINTENANCE
Cleaning
Warning! Many household cleaners contain
abrasive and chemical substances, and should not
be used for cleaning plated or plastic ttings. These nishes should be cleaned with a mild
washing up detergent or soap solution, and then wiped dry using a soft cloth.
Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the showerhead spray plate.
Do not use descalents on this product.
7. Temporarily t the two backplate screws to
the wallplate. This will prevent the holes from becoming blocked with plaster and grout.
8. Finish the surface of the wall as required ensuring the pipework is protruding by 18 mm ± 2 mm.
9. Remove the two backplate screws.
10. Place the backplate against the nished wall
surface and use the two backplate screws
supplied to x the backplate to the wallplate.
11. Follow steps 4 - 9 from previous section to complete the shower arm installation.
Alternative Installation procedure using the wallplate
1. Loosely screw the backplate to the wallplate
with the two backplate screws provided.
2. Place the wallplate and backplate assembly over the copper pipe.
3. Mark the position of the wallplate and its xing
holes on the wall.
Concealing Shroud
Olive
Compression Nut
Shower Arm
Copper Pipe
Backplate
Backplate Screw
6 mm Recess
1656.131
Backplate Assembly
4. Remove the screws and backplate from the wallplate.
5. Drill the two backplate xing holes, if necessary
make a recess approximately 6 mm deep to
accept the wallplate. Plug the two xing holes.
6. Place the wallplate over the copper pipe and
x to the wall with the two wallplate screws.
Flow Regulator (some models)
1536.159
Flow Regulator (12 l/min)
1. Mark the positions of the backplate fixing holes.
Caution! Be aware of hidden pipes or cables.
2. For solid walls drill the xing holes for the
backplate with a 6 mm drill and insert the wall plugs (supplied). For other types of wall
structure alternative xings may be required
(not supplied).
Caution! Take care not to drill into hidden
pipes or cables.
3. Carefully t the backplate over the outlet pipe and secure with the xing screws (supplied).
Caution! Take care not to damage the ‘O’ Seal
in the back of the backplate.
Screws
Backplate
Wall Plugs
Olive
Compression Nipple
5. Fit the concealing shroud onto the shower arm.
6. Fit the compression nut and olive onto the
shower arm.
7. Fit the shower arm into the compression nipple and tighten the compression nut.
4. Fit the olive and compression nipple over the outlet pipe and tighten the compression nipple.
8. Hand tighten the concealing shroud onto the backplate.
9. Screw the overhead onto the shower arm, if
necessary t the ow regulator.
Important! Certain mixing valves may have
ow regulators, refer to your shower control
installation and user guide for details.
Caution! The shower arm is not designed to
take weight, therefore care needs to be taken when installing the showerhead.
1799.012
Mira Beat 250 mm Showerhead - White
1799.011
Mira Beat 200 mm Showerhead - White
The Mira Shower Fittings have been designed for
domestic use only, Mira Showers guarantee the ttings
against any defect in materials or workmanship for a period of one year from the date of purchase.
For non-domestic installations, Mira Showers guarantee
the ttings against any defect in materials or workmanship
for a period of one year from the date of purchase.
For terms and conditions, refer to the back cover of this guide.
INSTALLATION
General
1. Make sure that the shower ttings are installed by a
competent installer.
2. Installations must comply with Water Regulations (Bye­Laws, Scotland), and any other Local Regulations and Building Regulations in force at the time of installation.
3. Before installation carefully inspect the new xture for
any signs of damage.
4. The shower fittings should be positioned at a convenient height for all the family and so that the deluge head will discharge down the centre of a bath or shower cubicle. Position the deluge head to spray across rather than towards the opening of the cubicle (if applicable) and also away from the shower control.
5. Special consideration should be given to the xing
arrangements when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative
proprietary cavity xings, or choose other options, however, these methods of xing are beyond the
scope of this guide.
Install the Shower Arm and Showerhead
The shower arm and showerhead must be tted after the
installation of the shower control and the outlet pipe must
protrude 18 mm (± 2 mm) from the nished wall surface. The outlet pipe must be tted at a suitable height and so
that the showerhead will discharge down the centre of a bath or shower cubicle.
1799.024
Overhead Wallplate
Loading...