Kohler MINIMA K-45803T-L-SHP, MINIMA K-45806T-L-SHP Installation Instructions Manual

BEFORE YOU BEGINBEFORE YOU BEGIN
MINIMA
INSTALLATION INSTRUCTIONS
SLIDING, 1 DOOR 1 PANEL
8mm K-45803T-L-SHP
10mm K-45806T-L-SHP
·
Before you install your shower door, please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information is based on the latest product
·
information available at the time of publication. Kohler China Ltd. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning,
·
and warranty information-
instructions for the consumer.
Make sure that the bath and the finished wall
·
material are completely and correctly installed prior to installing your shower door. Prepare waterproof layer to wall and floor of the showering area. It is not allowed for any presence of electric switches and sockets. Make sure the floor drain runs smoothly. Before starting the door installation, lay out and
·
identify all the parts. Use the exploded view illustrated on page 2 for reference. For the installation method of customized shower
·
with different dimensions, please refer to this instructions.
CAUTION: Risk of injury or product damage.
Tempered glass cannot be cut, drilled or knocked by hard object. Make sure corner area of the glass refraining from knocking so as to cause personal injury due to broken glass.
ATTENTION:
receptors or curbs. (Not included). If the curb is not Kohler-branded, please note its top width should be more than 80mm.
IMPORTANT:
finished wall. The squareness of the wall is recommended no more than 3 mm/m. KOHLER Company won't take responsibility of the installation quality.
Please install this door on Kohler
The shower door requires a flat vertical
please leave these
·
·
·
·
·
2
·
(
) 80mm
3mm/m
1198141-T01-B
-1-
13-1 528437
, 2014
ROUGHING-IN
H
B
PARTS IDENTIFICATIONPARTS IDENTIFICATION
IMPORTANT
Unit: mm
SKU B H
K-45803T K-45806T
1200-1600 1850-2000
Before installation check that all components are correctly supplied.
If any parts are missing please ring the helpline.
800-820-2628
Top Lintel
Inline Panel
Wall Channel
C
Glass Clamp
800-820-2628
Door Panel
1198141-T01-B
Threshold
Splashguard
-2-
Wall Channel
Cover Seal
4mm Allen key 4mm
Top Roller Clamps
Mid-support Clamp
X6
A
B
2.5mm Allen Key
2.5mm
X4
C
Screw Covers
X7
Screw Covers
X4
Support Strip
X2
X2
Bottom Guide
End Socket
Door Closing Guide
Plastic Guides
Frame Cap,LH Frame Cap,RH
X4
Wall Plugs
X7
X2
Wedge
ED
Handle
1198141-T01-B
-3-
INSTALLATION REQUIREMENTSINSTALLATION REQUIREMENTS
Tools Required
·
Phillips Screwdriver
·
Pencil
·
Caulk Gun
·
Measuring Tape
·
Safety Glasses
·
Center Punch
·
Hammer
·
Knife
·
Masonry Drill & 6mm Drilll Bit
·
Level
Materials Required
·
Drop Cloth Tape
·
Silicone Sealant
·
INSTALLATION
Fit tray and then tile walls before fitting the unit.
·
·
·
·
·
·
·
·
·
·
·
·
·
NOTE: Glass seal will extend out of wall channel.
A
6mm
Fit Wall Channel 'A'
A
1
X3
6mm
X3
2
0mm
Tray MUST be level in all planes or the unit will not install properly.
STEP
3
X3
0mm
4
Wall channels
MUST
plumb.
be
A
X3
5
STEP
1
Ensure the support strips are still on the bottom edge of the inline panel, inside the H section, and that the H section is 53mm from the corner of the glass.
2
1198141-T01-B
53mm
53mm
STEP
3
-4-
Loading...
+ 8 hidden pages