Kohler KT6908, KT6913, KT6910 User Manual

Installation Guide
Single-Control Bath and Shower Trim
K-T6913
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page“ Français-1” Español, página“ Español-1”
114487-2-CC
Tools and Materials
Strap Wrench
Assorted Screwdrivers
Thermometer
Plumbers Putty
Thread Sealant
Before You Begin
CAUTION: Risk of product damage. Long screws, for installing trim, can damage the K-2971-KS valve. When using this valve and trim in a fiberglass or acrylic installation, use the 88526 Thin Wall Installation Kit.
Observe all local plumbing and building codes.
The finished wall or bath/shower unit must be installed prior to installing this trim.
Before installing the trim, determine if the maximum water temperature is acceptable to the user. If temperature adjustment is needed, refer to the Optional Temperature Limiting Adjustment section of this guide.
The valve shuts off by water pressure. Do not force the handle in any direction. To turn the valve off, gently turn it to the OFF position.
Hex Wrench
114487-2-CC 2 Kohler Co.
Nipple
Spout
Apply plumbers putty.
7/16" (1.1 cm)
1. Install the Spout
Remove the temporary nipple.
Apply thread sealant and install a 1/2nipple so it extends 7/16 (1.1 cm) beyond the finished wall.
Apply a bead of plumbers putty or other sealant around the inlet end of the spout according to the manufacturer’s instructions.
Apply thread sealant to the nipple and thread the spout onto the nipple.
Carefully tighten with a clean strap wrench.
Remove any excess putty.
Kohler Co. 3 114487-2-CC
Shower Elbow
Apply plumbers putty to Escutcheon.
Shower Arm
Setscrew
Showerhead
2. Install the Showerhead
NOTICE: Do not use thread sealant compound (pipe dope) on the shower arm threads. Instead, use thread sealant tape on the shower arm threads. This will avoid clogging the showerhead spray outlets.
Remove the temporary nipple from the shower elbow.
Apply a bead of plumbers putty or other sealant to the back of the escutcheon according to the putty manufacturer’s instructions.
Slide the escutcheon over the shower arm.
Apply thread sealant tape and install the shower arm to the shower elbow.
Carefully tighten with a clean strap wrench.
Press the escutcheon against the finished wall and secure with the setscrew.
Remove all excess putty.
Turn the main water supply on.
Run hot and cold water through the shower arm to flush out dirt and debris.
Apply thread sealant tape to the shower arm and thread the showerhead to the shower arm.
114487-2-CC 4 Kohler Co.
Standard High Flow Valve
Setscrew
Tab
Collar
Setscrew
Valve Stem
O-Ring
Valve
Tab
Collar
Valve Label
3. Water Temperature Adjustment
CAUTION: Risk of personal injury. To eliminate the risk of scalding, the water temperature should never be set above 120°F (49°C).
NOTE: Do not remove the O-ring and collar at this time. Removing the O-ring and collar will change the factory setting for the maximum water temperature.
Turn the valve clockwise to the full open position and let the hot water run for several minutes. Position a thermometer in the water stream and check the temperature.
For minor water temperature changes, adjust the setscrew, and recheck the water temperature.
For major water temperature changes, remove the O-ring and collar from the valve stem. Slowly rotate the valve stem until the desired maximum water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against the side of the tab.
Reinstall the O-ring, rotate the valve stem counterclockwise to shut the water off.
Recheck the water temperature.
Complete the information on the valve label (if supplied).
Kohler Co. 5 114487-2-CC
Valve
Valve
Faceplate
Handle
Screw
Handle
Graphics Ring
Sleeve
4. Install the Faceplate and Handle
Remove and discard the plaster guard and/or dome, if installed.
Rotate the valve stem fully counterclockwise to the OFF position.
Install the faceplate onto the valve so the notch is to the bottom and secure with screws. Do not overtighten the screws.
Install the graphics ring to the faceplate, and rotate it clockwise to lock it in place.
Fit the sleeve onto the valve.
Secure the handle in place with the screw.
Press the plug button firmly into place.
Screw
Plug Button
114487-2-CC 6 Kohler Co.
Loading...