IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE
CONSUMER
WARNING: Risk of scalding or other severe injury.
•
Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
•
Do not install a shut-off device on either outlet of this valve. The
installation of any such device may create a cross-flow condition
at the valve and affect the water temperature.
•
Factors that change the temperature of the water supplied to the
valve, such as seasonal water temperature changes, and water
heater replacement or servicing, will change the maximum water
temperature supplied by the valve and may create a scalding
hazard.
•
The pressure-balanced valve will not compensate for changes in
the water supply temperature; adjust the maximum water
temperature setting of this pressure-balanced valve when such
changes occur.
•
Pressure-balanced valves may not provide protection against
scalding if there is a failure of other temperature-limiting devices
elsewhere in the plumbing system.
The installer is responsible for installing the valve and adjusting the
maximum water temperature of this valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature
adjustment instructions in this document, in the United States please
contact our Customer Service Department at 1-800-4-KOHLER.
Outside the U.S., please contact your distributor.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in
the information box in the Homeowners Guide and on the valve label.
Retain the Homeowners Guide for future reference.
114498-2-E2Kohler Co.
Tools and Materials
Strap
Wrench
Assorted
Screwdrivers
Thermometer
Plumbers
Putty
Thread
Sealant
Hex
Wrench
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Before You Begin
Observe all local plumbing and building codes.
The finished wall or bath/shower unit must be installed prior to
installing this trim.
We recommend that you determine if the maximum water
temperature is acceptable before installing this trim. If
temperature adjustment is needed, refer to the ″Water
Temperature Adjustment″ section.
The valve shuts off by water pressure. Do not force the handle in
any direction. To turn the valve off, gently turn it to the ″Off″
position.
Shut off the main water supply.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Kohler Co.3114498-2-E
7/16"
(1.1 cm)
Apply
plumbers
putty.
1/2" Nipple
4-7/8" (12.4 cm)
Spout
6-1/4"
(15.9 cm)
1/2"
(1.3 cm)
Apply plumbers putty.
1/2" Nipple
7-3/4" (19.7 cm)
Non-Diverter
Spout
1/2" Nipple
7-3/4" (19.7 cm)
Diverter Spout
Apply plumbers putty.
1. Install the Spout
Remove the temporary nipple.
For the 4-7/8″ (12.4 cm) diverter spout: Apply thread sealant to a
1/2″ NPT nipple and install it to the bath elbow so it extends
7/16″ (1.1 cm) beyond the finished wall.
For the 7-3/4″ (19.7 cm) diverter spout: Apply thread sealant to a
1/2″ NPT nipple and install it to the bath elbow so it extends
1/2″ (1.3 cm) beyond the finished wall.
For the 7-3/4″ (19.7 cm) non-diverter spout: Apply thread sealant
to a 1/2″ NPT nipple and install it to the bath elbow so it extends
6-1/4″ (15.9 cm) beyond the finished wall.
Apply a bead of plumbers putty or other sealant around the inlet
end of the spout according to the manufacturer’s instructions.
Apply thread sealant to the nipple, and install the spout to the
nipple.
Carefully tighten with a clean strap wrench.
Remove excess putty.
114498-2-E4Kohler Co.
Shower Elbow
Apply plumbers putty
to escutcheon.
Escutcheon
Sleeve
O-Ring
Setscrew
Shower Arm
Collar
Showerhead
2. Install Shower Arm and Showerhead
Remove the temporary nipple from the shower elbow.
Apply a bead of plumbers putty or other sealant to the back of
the escutcheon according to the manufacturer’s instructions.
Install the O-ring and sleeve to the escutcheon.
Slide the collar, sleeve, and escutcheon onto the shower arm.
Apply thread sealant tape and install the shower arm to the
shower elbow.
Carefully tighten with a clean strap wrench.
Press the escutcheon and sleeve against the finished wall.
Slide the collar tight against the sleeve and escutcheon, and
secure with the setscrew.
Remove all excess putty.
Flush out the system.
Apply thread sealant tape to the shower arm and thread the
showerhead to the shower arm.
Kohler Co.5114498-2-E
Standard
High Flow
Valve
Setscrew
Tab
Collar
Setscrew
Valve
Stem
O-Ring
Valve
Tab
Collar
Valve
Label
3. Water Temperature Adjustment
CAUTION: Risk of personal injury. The water temperature
should never be set above 120° F (49° C).
NOTE: Do not remove the O-ring and collar at this time. Removing
the O-ring and collar will change the factory setting for the
maximum water temperature.
Turn the valve clockwise to the full open position and let the hot
water run for several minutes. Position a thermometer in the
water stream and check the temperature.
For minor water temperature changes, adjust the setscrew, and
recheck the water temperature.
For major water temperature changes, remove the O-ring and
collar from the valve stem. Slowly rotate the valve stem until the
desired maximum water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against
the side of the tab.
Reinstall the O-ring, rotate the valve stem counterclockwise to
shut the water off.
Recheck the water temperature.
Complete the information on the valve label (if supplied).
114498-2-E6Kohler Co.
Valve Stem
Discard plaster
guard with dome.
Faceplate
Bonnet
O-Ring
Valve Stem
Sleeve
End Cap
Washer
Short Sleeve
Screw
Center Cap
Centering Washer
Screws
Long Sleeve
Handle Arm
4. Install the Faceplate and Lever Handle
CAUTION: Risk of product damage to the K-306–KS valve
assembly. When using this valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
Remove and discard the plaster guard and/or dome, if installed.
Fit the faceplate and centering washer over the valve, and secure
with two screws.
Rotate the valve stem fully counterclockwise.
Lever Handle
Fit a sleeve and bonnet over each stem adapter.
Thread a bonnet to each valve body until they are tight against
the escutcheon.
Install a center cap to each bonnet.
Fit a long sleeve to each handle arm, and secure it with the end
cap.
Insert a handle arm through each center cap and bonnet.
Install a short sleeve and washer onto each handle arm and
secure them with the end cap.
Kohler Co.7114498-2-E
End Cap
Washer
Sleeve
Short
Stud
Long Arm
Center Cap
Long Stud
Sleeve
End Cap
Valve Stem
Washer
End Cap
O-Ring
(4 Places)
Sleeve
Bonnet
Screw
Sleeve
Washer
5. Installing Other Handle Styles
Cross Handle
Install the sleeve and bonnet to the valve stem.
Align the bonnet and secure to the valve stem with the screw.
Fit the center cap to the bonnet so the holes align.
Insert the long arm into the large holes in the center cap so the
holes align.
Insert the long and short studs into the remaining center cap
holes and securely thread together.
Insert the O-rings, sleeves, washers, and end caps to the handle
ends.
114498-2-E8Kohler Co.