Kohler K1583PB Installation Manual

Installation Guide
Kitchen Sink Faucet
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1”
1015072-2-D
Tools and Materials
Adjustable Wrench
Plumbers Putty
Tube Cutter
Assorted Screwdrivers
Thread Sealant
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don’t hesitate to contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler Company.
Before You Begin
Observe all local plumbing and building codes.
Shut off the water supplies.
Before installation, unpack the new faucet and inspect it for damage. Return the faucet to the carton until you are ready to install it.
Carefully inspect waste and supply tubing for any sign of damage and replace if necessary.
For new installations, assemble the faucet to the sink before installing the sink.
If supply tubes must be cut, allow for required penetration into shut-off valve.
Kohler Co. reserves the right to make revisions in the design of faucets without notice, as specified in the Price Book.
1015072-2-D 2 Kohler Co.
Handspray
Spout
Escutcheon
Sink
Washer
Shank Nut
Handspray Hose
O-Ring
Shank
Shank Tee
Spray Holder
Nut
Apply plumbers putty.
1. Install the Spout and Handspray
NOTE: Before applying plumbers putty or other sealant to the escutcheon, make sure the O-ring is in place in the groove on the interior surface.
Apply a bead of plumbers putty or other sealant to the underside of the escutcheon according to the manufacturer’s instructions.
Thread the shank nut and washer to the bottom of the shank.
Insert the shank from the bottom of the sink.
Slide the escutcheon over the shank.
Thread the spout to the bottom of the shank, then loosen the spout 1/8 of a turn.
Loosen the shank 1/8 of a turn.
IMPORTANT! Do not loosen the shank more than 1/2 turn. The spout may not seal, resulting in a leak.
Tighten the nut and washer to secure the spray holder to the sink.
Slide the gasket (provided) onto the spray holder.
Slide the spray holder through the mounting hole from above.
Securely hand tighten the nut to the spray holder from under the sink.
Insert the handspray hose through the spray holder.
Attach the handspray hose to the shank tee using thread sealant.
Kohler Co. 3 1015072-2-D
Escutcheon
Apply plumbers putty.
Valve Body
Valve Body Outlet
Coupling Nut Threads
Shank Te e
Hose
Washer
Nut
2. Install the Valve Body
Apply thread sealant to the coupling nut threads of the flexible hoses.
Thread the flexible hoses to the valve body outlets and wrench tighten. Do not overtighten.
Apply a bead of plumbers putty or other sealant to the underside of the escutcheons according to the manufacturer’s instructions.
Insert the valve bodies into the mounting holes from the top of the sink. Make sure the hot valve body is installed in the left-hand hole and the cold valve body is installed in the right-hand hole.
Install a washer and then a nut to the bottom of the valve bodies.
Align the valve bodies so the copper tubing faces the outside.
Wrench tighten the nuts.
Remove any excess plumbers putty.
Connect and wrench tighten the hoses to the shank tee. Do not overtighten.
1015072-2-D 4 Kohler Co.
Screw
Lever Handle
Stem Extension
Escutcheon
Six-Prong Handle
Setscrew
Bonnet
Valve Stem
Screw
Stem Extension
3. Install the Handles
Set the valve stem to the closed position by rotating the stem counterclockwise until it stops.
Thread the bonnet onto the escutcheon.
Insert the stem extension into the bonnet and press it onto the valve stem.
Lever Handles
Properly align the lever handle.
Press the lever handle onto the stem extension.
Secure the lever handle with the screw.
Six-Prong Handles
Secure the stem extension with the screw.
Press the handle onto the stem extension with the text on the ceramic button properly aligned.
Secure the handle with the setscrew.
Kohler Co. 5 1015072-2-D
Valve Body Inlet
Supply Tube
Ferrule
Coupling Nut
Ferrule
Supply Stop
Valve Body Inlet
4. Install the Supplies
NOTE: If the sink is not installed, install it at this time. Be sure to follow all instructions packed with the sink.
Slide the coupling nuts and ferrules onto the supply tubes.
Secure the supply tubes and valve body inlets with coupling nuts.
Carefully insert the supply tubes into the valve body inlets and shut-off valve outlets (if used).
Position the round end of the supply tube squarely to the valve body inlet and supply stop.
Tighten all coupling nuts.
1015072-2-D 6 Kohler Co.
Aerator
5. Installation Checkout
Ensure that both faucet handles are turned off. Hot is clockwise close and cold is counterclockwise close.
Turn on the hot and cold water supplies.
Check for leaks.
Remove the aerator by turning it counterclockwise.
Turn on the hot and cold faucet handles for one minute to flush debris from the faucet.
Close the hot and cold faucet handles.
Reattach the aerator by turning it clockwise until hand tight.
Kohler Co. 7 1015072-2-D
Guide d’installation
Robinet d’évier de cuisine
Outils et matériels
Clé à molette
Mastic de plombier
Coupe-tubes
Tournevis assortis
Ruban d'étanchéité
Merci d’avoir choisi la compagnie Kohler
Nous apprécions votre engagement envers la qualité Kohler. Veuillez prendre s’il vous plaît quelques minutes pour lire ce manuel avant de commencer l’installation. Ne pas hésiter à nous contacter en cas de problème d’installation ou de performance. Nos numéros de téléphone et notre adresse du site internet sont au verso. Merci encore d’avoir choisi la compagnie Kohler.
Avant de commencer
Respecter tous les codes de plomberie et de bâtiment locaux.
Couper les alimentations d’eau.
Avant l’installation, déballer le nouveau robinet et l’examiner pour en déceler tout dommage. Remettre le robinet dans son emballage de protection jusqu’à être prêt à l’installation.
Vérifier avec soin si l’évacuation ou les tubes d’alimentation pour déceler tout signe d’endommagement et remplacer si nécessaire.
Pour de nouvelles installations, installer le robinet sur l’évier avant d’installer ce dernier.
Si les tubes d’alimentation d’eau doivent être coupés, prévoir la longueur requise pour l’emboîtement dans la valve d’arrêt.
Kohler Co. Français-1 1015072-2-D
Loading...