IMPORTANT SAFETY INSTRUCTIONS

ATTENTION INSTALLER: INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING: When using this unit, always follow basic precautions, including the following:
DANGER: RISK OF ELECTRICAL SHOCK. The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) for the whirlpool system.
This will provide additional protection against line-to-ground shock hazard.
Such a GFCI should be provided by the installer and should be tested on a routine basis.
T o test the GFCI, press the test button. The GFCI should interrupt power. Press the reset button. Power should be restored.
If the GFCI fails to operate in this manner, there is a ground current flowing or the GFCI is defective. The possibility of an electric shock may exist. DO NOT use this unit. Disconnect the unit and have the problem corrected by a qualified licensed electrician.
DO NOT operate this unit without the guard on the suction fitting.
Never drop or insert any object into any opening.
For -J1 and -JA models only: A green colored terminal (or a wire connector marked “G”, “GR”, “GROUND”, or “Grounding”) is provided within the terminal compartment. To reduce the risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment.
All models: A pressure wire connector is provided on the exterior of the pump or control box within this unit to permit connection of a No. 8 AWG (8.4 mm2) solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity , as needed to comply with local requirements.
Use this unit only for its intended use as denoted in this manual. DO NOT use attachments not recommended by the Kohler Co.
DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.
106548-CA (9437)
SAVE THESE INSTRUCTIONS
2

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS 2. . . . . . . .
INTRODUCTION 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ROUGHING-IN: K-1200-AC, K-1201-AC 5. . . . . . . .
Ordering Information 5. . . . . . . . . . . . . . . . . . . . . . .
Required Electrical Service 5. . . . . . . . . . . . . . . . . .
Product Information 5. . . . . . . . . . . . . . . . . . . . . . . .
Installation Notes 5. . . . . . . . . . . . . . . . . . . . . . . . . .
ROUGHING-IN: K-1205-AC, K-1206-AC 6. . . . . . . .
Ordering Information 6. . . . . . . . . . . . . . . . . . . . . . .
Required Electrical Service 6. . . . . . . . . . . . . . . . . .
Product Information 6. . . . . . . . . . . . . . . . . . . . . . . .
Installation Notes 5. . . . . . . . . . . . . . . . . . . . . . . . . .
ROUGHING-IN: K-1210-AC, K-1211-AC 7. . . . . . .
Ordering Information 7. . . . . . . . . . . . . . . . . . . . . . .
Required Electrical Service 7. . . . . . . . . . . . . . . . . .
Product Information 7. . . . . . . . . . . . . . . . . . . . . . . .
Installation Notes 7. . . . . . . . . . . . . . . . . . . . . . . . . .
ROUGHING-IN: K-1215-AC, K-1216-AC 8. . . . . . . .
Ordering Information 8. . . . . . . . . . . . . . . . . . . . . . .
Required Electrical Service 8. . . . . . . . . . . . . . . . . .
Product Information 8. . . . . . . . . . . . . . . . . . . . . . . .
Installation Notes 8. . . . . . . . . . . . . . . . . . . . . . . . . .
ROUGHING-IN: K-1220-AC, K-1221-AC 9. . . . . . . .
Ordering Information 9. . . . . . . . . . . . . . . . . . . . . . .
Required Electrical Service 9. . . . . . . . . . . . . . . . . .
Product Information 9. . . . . . . . . . . . . . . . . . . . . . . .
Installation Notes 9. . . . . . . . . . . . . . . . . . . . . . . . . .
PRODUCT NOTICES 10. . . . . . . . . . . . . . . . . . . . . . . . .
Installer Hazard Notification 10. . . . . . . . . . . . . . . . .
Factory-Assembled Features 10. . . . . . . . . . . . . . . .
PRODUCT REQUIREMENTS 11. . . . . . . . . . . . . . . . .
Summary of Key Requirements 11. . . . . . . . . . . . . .
Plumbing Specifications 11. . . . . . . . . . . . . . . . . . . . .
Product Inspection 11. . . . . . . . . . . . . . . . . . . . . . . . .
Connections and Service Access 11. . . . . . . . . . . . .
Electrical Requirements 11. . . . . . . . . . . . . . . . . . . . .
INSTALLATION REQUIREMENTS 12. . . . . . . . . . . . .
Tools Required 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Materials Required 12. . . . . . . . . . . . . . . . . . . . . . . . .
Clearance Requirements 12. . . . . . . . . . . . . . . . . . . .
New Or Replacement Installation Requirements 12
SITE REQUIREMENTS 13. . . . . . . . . . . . . . . . . . . . . . .
Remove Old Bath 13. . . . . . . . . . . . . . . . . . . . . . . . . .
Subfloor Preparation 13. . . . . . . . . . . . . . . . . . . . . . . .
Stud Pocket Preparation 13. . . . . . . . . . . . . . . . . . . .
Plumbing Preparation 14. . . . . . . . . . . . . . . . . . . . . . .
BEFORE INSTALLING UNIT 14. . . . . . . . . . . . . . . . . .
Tiling-In Bead Installation 14. . . . . . . . . . . . . . . . . . . .
Partially Install Bath Drain 14. . . . . . . . . . . . . . . . . . .
Protect Bath Unit 14. . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALL WHIRLPOOL 15. . . . . . . . . . . . . . . . . . . . . . .
Whirlpool Set-In 15. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Height Adjustment 16. . . . . . . . . . . . . . . . . . . . . . . . .
Secure Whirlpool 16. . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Plumbing 16. . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL CONNECTIONS -
AIR ACTUATOR VERSIONS 17. . . . . . . . . . . . . . . . . .
Identify Electrical Requirements 17. . . . . . . . . . . . . .
Wiring Information - 120 V, 60 Hz 17. . . . . . . . . . . .
Locate Field Wiring Compartment - 120 V, 60 Hz 18
Field Wiring Diagram - 120 V, 60 Hz 18. . . . . . . . . .
Field Wiring Control Box Compartment -
230 V, 50 Hz 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Control Box - 230 V, 50 Hz 19. . . . . . . . . .
ELECTRICAL CONNECTIONS -
WALL TIMER VERSIONS 20. . . . . . . . . . . . . . . . . . . . .
Identify Electrical Requirements 20. . . . . . . . . . . . . .
Wiring Infromation - 120 V, 60 Hz -
Wall Timer Versions 20. . . . . . . . . . . . . . . . . . . . . . . .
WATER TEST WHIRLPOOL AND ELECTRONICS 21
COMPLETE FINISH WALL 21. . . . . . . . . . . . . . . . . . . .
OPTIONAL K-1507 APRON INSTALLATION 22. . . . .
OPTIONAL K-1515 APRON INSTALLATION 23. . . . .
COMPLETE INSTALLATION 24. . . . . . . . . . . . . . . . . .
CLEAN-UP AFTER INSTALLATION 24. . . . . . . . . . . .
CONFIRM PROPER OPERATION 25. . . . . . . . . . . . .
Start-Up Whirlpool 25. . . . . . . . . . . . . . . . . . . . . . . . .
Operating Sequence 25. . . . . . . . . . . . . . . . . . . . . . . .
Troubleshoot Whirlpool System 26. . . . . . . . . . . . . .
Kohler Co., Kohler WI
3
106548-CA (9437)

INTRODUCTION

Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will aid you in avoiding the unnecessary expense associated with improper installation. In addition to proper installation, read all operating and safety instructions.
The variety of installations possible with this whirlpool may require framing procedures other than those described in this manual.
All information in this manual is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.
Identify and record below the model and serial number (found at the pump end of the whirlpool): Model No. Serial No. Date of Manufacture
106548-CA (9437)
4
1. ROUGHING-IN: K-1200-AC, K-1201-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch transmitter.
Information contained in this roughing-in also applies to K-1201-J1-AA, K-1201-J1-AB and K-1201-JA-AA.
Whirlpool with wall timer K-1200-AC Whirlpool with air actuator (shown) K-1201-AC Accessories/hardware: Drain K-7161-AF recom-
mended Vinyl tiling-in bead* K-1177 optional *Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture: basin area top area weight Bathing well 42” x 17” 55” x 25” 93 lbs.
water depth capacity
To overflow 12-1/8” 50 gals.
Pump: hp V Hz A 60 Hz 1/2 120 60 8
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before beginning installation.
15”
1-1/2”
2-3/4”
FIELD WIRING COMPARTMENT
8-1/2”
60”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler­ances in ANSI Standard Z124.1.
No change in measurements if connected with drain illustrated.
Cut-out 28-1/2” x 58-1/2” Minimum access: Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
30”
1-1/2”
17”
1.25>132
Kohler Co., Kohler WI
2-7/8” 3”
3/16”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
5
106548-CA (9437)
2. ROUGHING-IN: K-1205-AC, K-1206-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch transmitter.
Information contained in this roughing-in also applies to K-1206-J1-AA, K-1206-J1-AB and K-1206-JA-AA.
Whirlpool with wall timer K-1205-AC Whirlpool with air actuator (shown) K-1206-AC Accessories/hardware: Drain K-7161-AF recom-
mended Vinyl tiling-in bead* K-1177 optional *Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture: basin area top area weight Bathing well 44” x 22” 55” x 25” 100 lbs.
water depth capacity
To overflow 15-1/8” 60 gals. Pump: hp V Hz A
60 Hz 1/2 120 60 8
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before beginning installation.
16”
1-3/8”
2-3/4”
FIELD WIRING COMPARTMENT
8-3/8”
60”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler­ances in ANSI Standard Z124.1.
No change in measurements if connected with drain illustrated.
Cut-out 30-1/2” x 58-1/2” Minimum access: Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
32”
1-1/2”
20”
1.25>132
106548-CA (9437)
2-7/8” 3”
3/8”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
6
3. ROUGHING-IN: K-1210-AC, K-121 1-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch transmitter.
Information contained in this roughing-in also applies to K-1211-J1-AA, K-1211-J1-AB and K-1211-JA-AA.
Whirlpool with wall timer K-1210-AC Whirlpool with air actuator (shown) K-1211-AC Accessories/hardware: Drain K-7161-AF recom-
mended Vinyl tiling-in bead* K-1179 optional *Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture: basin area top area weight Bathing well 39” x 22” 54” x 27” 85 lbs.
water depth capacity
To overflow 15-1/2” 65 gals. Pump: hp V Hz A
60 Hz 1/2 120 60 8
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before beginning installation.
*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.
18”
1-7/8”
3-1/4”
FIELD WIRING COMPARTMENT
8-7/8”
59-9/16”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler­ances in ANSI Standard Z124.1.
No change in measurements if connected with drain illustrated.
Cut-out 34-1/2” x 58-1/2” Minimum access: Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
1-3/4”
21”
36”
1.25>132
Kohler Co., Kohler WI
2-7/8” 3”
1-1/8”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
7
106548-CA (9437)
4. ROUGHING-IN: K-1215-AC, K-1216-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch transmitter.
Information contained in this roughing-in also applies to K-1216-J1-AA and K-1216-JA-AA.
Whirlpool with wall timer K-1215-AC Whirlpool with air actuator (shown) K-1216-AC Accessories/hardware: Drain K-7161-AF recom-
mended Vinyl tiling-in bead* K-1179 optional *Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture: basin area top area weight Bathing well 52” x 23” 65-1/2” x
26-1/2”
water depth capacity
To overflow 15-1/2” 76 gals. Pump: hp V Hz A
60 Hz 3/4 120 60 10
95 lbs.
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before beginning installation.
*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.
18”
1-7/8”
3”
FIELD WIRING COMPARTMENT
PUMP
8-7/8”
71-3/16”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler­ances in ANSI Standard Z124.1.
No change in measurements if connected with drain illustrated.
Cut-out 34-1/2” x 70” Minimum access: Pump/control box 20” W x 15” H panel required
PUMP/CONTROL ACCESS
36”
1-3/4”
21”
1.25>132
106548-CA (9437)
2-7/8”
3”
15/16”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
8
5. ROUGHING-IN: K-1220-AC, K-1221-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch transmitter.
Information contained in this roughing-in also applies to K-1221-J1-AA and K-1221-JA-AA.
Whirlpool with wall timer K-1220-AC Whirlpool with air switch (shown) K-1221-AC Accessories/hardware: Drain K-7161-AF recom-
mended Apron K-1223 optional Vinyl tiling-in bead* K-1179 optional *Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture: basin area top area weight Bathing well 47” x 37” 67” x 32” 120 lbs.
water depth capacity
To overflow 16-7/8” 117 gals. Pump, 1 phase hp RPM V Hz A
60 Hz 3/4 3450 120 60 10
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before beginning installation.
*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.
24”
3-1/2”
2”
9”
FIELD WIRING COMPARTMENT
PUMP
72”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler­ances in ANSI Standard Z124.1.
No change in measurements if connected with drain illustrated.
Cut-out 46-1/4” x 70-1/4” Minimum access: Pump/control box 20” W x 15” H panel required