ATTENTION INSTALLER: INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING: When using this unit, always follow basic precautions, including the following:
DANGER: RISK OF ELECTRICAL SHOCK.
The installation must have a Class A
Ground-Fault Circuit-Interrupter (GFCI) for the
whirlpool system.
This will provide additional protection against
line-to-ground shock hazard.
Such a GFCI should be provided by the installer and
should be tested on a routine basis.
T o test the GFCI, press the test button. The GFCI should
interrupt power. Press the reset button. Power should be
restored.
If the GFCI fails to operate in this manner, there is a
ground current flowing or the GFCI is defective. The
possibility of an electric shock may exist. DO NOT use
this unit. Disconnect the unit and have the problem
corrected by a qualified licensed electrician.
DO NOT operate this unit without the guard on the
suction fitting.
Never drop or insert any object into any opening.
For -J1 and -JA models only: A green colored terminal
(or a wire connector marked “G”, “GR”, “GROUND”, or
“Grounding”) is provided within the terminal
compartment. To reduce the risk of electric shock,
connect this terminal or connector to the grounding
terminal of your electric service or supply panel with a
conductor equivalent in size to the circuit conductors
supplying this equipment.
All models: A pressure wire connector is provided on
the exterior of the pump or control box within this unit to
permit connection of a No. 8 AWG (8.4 mm2) solid
copper bonding conductor between this unit and all other
electrical equipment and exposed metal in the vicinity , as
needed to comply with local requirements.
Use this unit only for its intended use as denoted in this
manual. DO NOT use attachments not recommended
by the Kohler Co.
DANGER: To reduce the risk of injury, do not
permit children to use this unit unless they are
closely supervised at all times.
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and
installation sequences. Follow the sections that pertain
to your particular installation. This will aid you in avoiding
the unnecessary expense associated with improper
installation. In addition to proper installation, read all
operating and safety instructions.
The variety of installations possible with this whirlpool
may require framing procedures other than those
described in this manual.
All information in this manual is based on the latest
product information available at the time of publication.
Kohler Co. reserves the right to make changes in
product characteristics, packaging, or availability at any
time without notice.
Identify and record below the model and serial number (found at the pump end of the whirlpool):
Model No.Serial No.Date of Manufacture
106548-CA (9437)
4
Kohler Co., Kohler WI
1. ROUGHING-IN: K-1200-AC, K-1201-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1201-J1-AA, K-1201-J1-AB and K-1201-JA-AA.
Whirlpool with wall timerK-1200-AC
Whirlpool with air actuator (shown)K-1201-AC
Accessories/hardware:
DrainK-7161-AF recom-
mended
Vinyl tiling-in bead*K-1177optional
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture:basin areatop areaweight
Bathing well42” x 17”55” x 25”93 lbs.
water depthcapacity
To overflow12-1/8”50 gals.
Pump:hpVHzA
60 Hz1/2120608
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
15”
1-1/2”
2-3/4”
FIELD WIRING COMPARTMENT
8-1/2”
60”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to tolerances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out28-1/2” x 58-1/2”
Minimum access:
Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
30”
1-1/2”
17”
1.25>132
Kohler Co., Kohler WI
2-7/8”
3”
3/16”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
5
106548-CA (9437)
2. ROUGHING-IN: K-1205-AC, K-1206-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1206-J1-AA, K-1206-J1-AB and K-1206-JA-AA.
Whirlpool with wall timerK-1205-AC
Whirlpool with air actuator (shown)K-1206-AC
Accessories/hardware:
DrainK-7161-AF recom-
mended
Vinyl tiling-in bead*K-1177optional
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture:basin areatop areaweight
Bathing well44” x 22”55” x 25”100 lbs.
water depthcapacity
To overflow15-1/8”60 gals.
Pump:hpVHzA
60 Hz1/2120608
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
16”
1-3/8”
2-3/4”
FIELD WIRING COMPARTMENT
8-3/8”
60”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to tolerances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out30-1/2” x 58-1/2”
Minimum access:
Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
32”
1-1/2”
20”
1.25>132
106548-CA (9437)
2-7/8”
3”
3/8”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
6
Kohler Co., Kohler WI
3. ROUGHING-IN: K-1210-AC, K-121 1-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1211-J1-AA, K-1211-J1-AB and K-1211-JA-AA.
Whirlpool with wall timerK-1210-AC
Whirlpool with air actuator (shown)K-1211-AC
Accessories/hardware:
DrainK-7161-AF recom-
mended
Vinyl tiling-in bead*K-1179optional
*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture:basin areatop areaweight
Bathing well39” x 22”54” x 27”85 lbs.
water depthcapacity
To overflow15-1/2”65 gals.
Pump:hpVHzA
60 Hz1/2120608
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.
18”
1-7/8”
3-1/4”
FIELD WIRING COMPARTMENT
8-7/8”
59-9/16”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to tolerances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out34-1/2” x 58-1/2”
Minimum access:
Pump/control box 20” W x 15” H panel required
PUMP
PUMP/CONTROL ACCESS
1-3/4”
21”
36”
1.25>132
Kohler Co., Kohler WI
2-7/8”
3”
1-1/8”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
7
106548-CA (9437)
4. ROUGHING-IN: K-1215-AC, K-1216-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1216-J1-AA and K-1216-JA-AA.
Whirlpool with wall timerK-1215-AC
Whirlpool with air actuator (shown)K-1216-AC
Accessories/hardware:
DrainK-7161-AF recom-
mended
Vinyl tiling-in bead*K-1179optional
*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture:basin areatop areaweight
Bathing well52” x 23”65-1/2” x
26-1/2”
water depthcapacity
To overflow15-1/2”76 gals.
Pump:hpVHzA
60 Hz3/41206010
95 lbs.
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.
18”
1-7/8”
3”
FIELD WIRING COMPARTMENT
PUMP
8-7/8”
71-3/16”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to tolerances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out34-1/2” x 70”
Minimum access:
Pump/control box 20” W x 15” H panel required
PUMP/CONTROL ACCESS
36”
1-3/4”
21”
1.25>132
106548-CA (9437)
2-7/8”
3”
15/16”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
8
Kohler Co., Kohler WI
5. ROUGHING-IN: K-1220-AC, K-1221-AC
A. ORDERING INFORMA TION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1221-J1-AA and K-1221-JA-AA.
Whirlpool with wall timerK-1220-AC
Whirlpool with air switch (shown)K-1221-AC
Accessories/hardware:
DrainK-7161-AF recom-
mended
ApronK-1223optional
Vinyl tiling-in bead*K-1179optional
*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control120 V., 15 A, 60 Hz
C. PRODUCT INFORMA TION
Fixture:basin areatop areaweight
Bathing well47” x 37”67” x 32”120 lbs.
water depthcapacity
To overflow16-7/8”117 gals.
Pump, 1 phasehpRPMVHzA
60 Hz3/434501206010
D. INST ALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.
24”
3-1/2”
2”
9”
FIELD WIRING
COMPARTMENT
PUMP
72”
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to tolerances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out46-1/4” x 70-1/4”
Minimum access:
Pump/control box 20” W x 15” H panel required
PUMP/CONTROL ACCESS
48”
1-3/4”
23”
Kohler Co., Kohler WI
2-7/8”
3”
13/16”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
9
1.15>132
106548-CA (9437)