Kohler K-1111-VLN Homeowner's Manual

Homeowners Guide
Bath Whirlpool
K-1111-VLN
M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página Español-1”
Operating Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed, including the following:
DANGER: Risk of personal injury. To reduce the risk of injury, do not permit children to use this
unit unless they are closely supervised at all times.
WARNING: Risk of personal injury. To avoid injury, exercise care when entering or exiting the whirlpool.
WARNING: Risk of electric shock. Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or television) within 5’ (1.5 m) of this whirlpool.
WARNING: Risk of hyperthermia. People using medications and/or having an adverse medical history should consult a physician before using a whirlpool equipped with a heater.
WARNING: Risk of scalding. Do not allow the water temperature in the whirlpool to exceed 104°F (40°C).
Use this whirlpool only for its intended purpose as described in this manual. Do not use attachments not recommended by the manufacturer.
Never drop or insert any object into any opening. Keep small objects such as bath toys and bathing accessories out of the whirlpool while the unit is running.
Do not operate this unit without the guard (cover) over the suction fitting. The whirlpool must be connected only to a supply circuit that is protected by a Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Such a GFCI or RCD should be provided by the installer and should be tested on a routine basis. To test the GFCI or RCD, press the test button. The GFCI or RCD should interrupt power. Press the reset button. Power should be restored. If the GFCI or RCD fails to operate in this manner, the GFCI or RCD is defective. If the GFCI or RCD interrupts power to the bath without the test button being pressed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this whirlpool bath. Disconnect the whirlpool and have the problem corrected by a qualified service representative before using.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: (a) failure to perceive heat, (b) failure to recognize the need to exit the bath, (c) unawareness of impending hazard, (d) fetal damage in pregnant women, (e) physical inability to exit the bath, and (f) unconsciousness resulting in the danger of drowning.
Flush your whirlpool system twice a month or more depending upon usage, as described in the Flush Systemsection.
Repeated use of personal care products containing oils can damage plastic whirlpool components. Do not use heavy, vegetable-based shampoos or bath oils.
Whirlpool hydro-massage action can cause even a small amount of bubble bath, bath soap, shampoo, or bath oil to foam excessively. For this reason, please don’t use these products during whirlpool operation.
1042760-5-D 2 Kohler Co.
Thank You For Choosing Kohler Company
Thank you for choosing Kohler Company. Your Kohler Company product reflects the true passion for design, craftsmanship, artistry, and innovation Kohler Company stands for. We are confident its dependability and beauty will surpass your highest expectations, satisfying you for years to come.
All information in this guide is based upon the latest product information available at the time of publication. At Kohler Company, we strive to fulfill our mission of improving the level of gracious living for each person who is touched by our products and services. We reserve the right to make changes in product characteristics, packaging, or availability at any time without notice.
Please take a few minutes to review this guide. Pay special attention to the care and cleaning instructions.
Kohler Co. 3 1042760-5-D
The user keypad (2 provided) allows you to turn the whirlpool and heater on and off and regulate the water flow.
The bath provides a reservoir for the hydro-massage action.
Adjustable jets allow you to adjust the air and water flow and direction.
The pump motor (2 provided) provides quiet, variable speed power to circulate the water.
NOTE: Bath shown for illustrative
Backjets
The heater (2 provided) helps maintain the water temperature up to 104˚F (40˚C).
purposes. Your bath model may vary.
Your Kohler Whirlpool
The whirlpool is equipped with the following components:
Bath - The bath acts as a reservoir for water and provides a location for the hydro-massage action.
User Keypads (2) - Located within easy reach, the keypads allow you to turn the whirlpool on and off, access all the whirlpool modes, and regulate the water flow or pulse speed. Available modes will be illuminated in blue. Active modes will be illuminated in green.
Pump Motors (2) - The pump motors provide quiet, variable speed power to circulate the water and create the soothing hydro-massage action.
Adjustable Jets - The adjustable jets may be positioned to optimize their hydro-massage effect. The trim on the adjustable jets allow you to adjust the air and water flow.
Heaters (2) - The heaters are designed to automatically help maintain the temperature of the water up to 104°F (40°C) to enhance your hydro-massage experience. The heaters turn on automatically when the whirlpool is operating and turn off when the pump motors are turned off. The heaters may be turned off through the keypad at any time while the pump motors are operating.
Pillows - The pillows provide a comfortable place to rest your head as you relax.
Remote Controls (2) - The waterproof remote controls bring all the whirlpool features to your fingertips.
Chromatherapy - Add ambience to your bath with lights that automatically and continuously cycle through the eight colors, or select just one color: white, violet, indigo blue, aqua blue, green, yellow, orange, and red. One cycle through all eight colors takes approximately one minute. This mode may be used with all modes of operation and also when the pumps are not operating.
LED Lights (3) - The LED lights illuminate the ledge separating the two bath spaces.
Effervescence Ports - The effervescence ports are intended to be a relaxing, soothing experience. The Flexjets and backjets will automatically turn off when the effervescence mode is activated.
Backjets - This mode delivers massaging water to your back. The backjets pulse from the bottom to the top of the whirlpool. Water flow and pulse action occur from two backjets at a time.
1042760-5-D 4 Kohler Co.
Flexjet Flow Mode Activates Mode Selected
Backjet Mode­Adjust Pulse
Rotate outer
Increases Flow or Pulse Rate
Effervescence Mode
Indicator Bar - Shows Water Flow Volume or Pulse Rate
ring to access desired mode.
Chromatherapy ­Specific Color
Power On/Off
Heater On/Off
Lighted User Keypad
Chromatherapy Cycle
Decreases Flow
Keypad above shows all features
Note:
available. Your keypad may vary based on your whirlpool model.
User Keypads
Available modes will be illuminated in blue. Active modes will be illuminated in green. Power Icon Turns the whirlpool pump on and off. Icons illuminated in blue indicate available
Chromatherapy Specific Color
Outer Ring Rotate the outer ring to the desired mode. The selected mode will flash blue. Backjet Mode Rotate the outer ring to select this mode. Press OK, then press the up or down arrow to
OK Activates the desired mode. Flexjet Flow
Mode Up Arrow Increases the water flow when the Flexjet flow mode is active. Increases the pulse speed
Effervescence Mode
Indicator Bar Displays the water flow volume in the Flexjet flow mode. Displays the pulse speed in the
Chromatherapy Cycle
Down Arrow Decreases the water flow when the Flexjet flow mode is active. Decreases the pulse speed
Heater Automatically engages when the power icon is selected. Rotate the outer ring until the
modes/features. Modes which are operating will be illuminated in green. Rotate the outer ring to select this mode. Press OK, press the up or down arrow to select a
color, then press OK again. Only one of the two keypads controls this mode.
increase or decrease the pulsing action. Rotate the outer ring to the Flexjet mode, press OK to activate the mode, then press the up or down arrow on the keypad to increase or decrease water flow to the backjets and all other active modes.
Rotate the outer ring to select this mode. Press OK, then press the up or down arrow to increase or decrease the jet water flow.
when the neckjet or backjet mode is active. Rotate the outer ring to select this mode, then press OK. The effervescence action will start
at the water flow volume last set in the Flexjet flow mode. Press the up or down arrow to increase or decrease the water flow. Press OK while the effervescence mode is flashing to turn off the effervescence ports.
neckjet or backjet mode. Rotate the outer ring to select this mode, then press OK. The chromatherapy lights will
automatically and continuously cycle through eight colors. One cycle through all eight colors takes approximately one minute. Only one of the two keypads controls this mode.
when the neckjet or backjet mode is active.
heater mode is flashing, then press OK to turn the heater off. Press OK again to turn the heater back on.
Kohler Co. 5 1042760-5-D
Fill with water until the backjet level probes are covered with water.
Level Probes
Position the jet nozzles
Turn the Flexjet trim clockwise to
to direct the water flow as desired.
decrease the flow.
Turn the Flexjet trim counterclockwise to increase the flow.
Operation
NOTE: Please read these steps carefully before operating your whirlpool.
NOTE: The water temperature in the whirlpool should not exceed 104°F (40°C). The heater will
automatically turn off as the water temperature approaches 104°F (40°C) and will remain off until the water cools.
Turn the jet trim fully counterclockwise. Position the jet nozzles so they face down toward the basin.
Close the drain and fill the bath above the backjet level probes. Place your hand in the bath to test the water temperature for comfort and safety, then carefully
enter the bath. Press the power icon. The heater will turn on and the whirlpool will start at a medium water flow
volume. The chromatherapy cycle icon will illuminate on the keypad and three small lights near the whirlpool floor will illuminate until the keypad goes into sleep mode.
Press the up or down arrow to increase or decrease the water flow volume. The indicator bar in the center of the keypad will display the current water flow volume.
Rotate the jet trim clockwise to reduce the air/water flow or counterclockwise to increase the air/water flow.
Position the Flexjet nozzles to direct the water flow to maximize your hydro-massage experience. Rotate the outer ring until the heater mode is flashing, then press OK. The heater will turn off. Press
OK again to turn the heater back on.
NOTE: In backjet mode, if the water level is lower than the backjet level probes, this mode will stop. The backjet icon and indicator bar on the user keypad will flash. The backjet mode will automatically restart when the water level reaches the backjet level probes.
Rotate the outer ring until the backjet mode is flashing, then press OK. Press the up or down arrow to increase or decrease the pulsing action. Rotate the outer ring to the Flexjet mode, press OK to activate the mode, then press the up or down arrow on the keypad to increase or decrease water flow to the backjets and all other active modes.
Rotate the outer ring until the chromatherapy cycle is flashing, then press OK to activate it. Press OK while the chromatherapy mode is active to turn off this mode.
Rotate the outer ring to the chromatherapy specific color. When flashing, press OK to activate it. Press the up or down arrow to reach the desired color, then press OK to activate the desired color.
Press the power icon to turn the whirlpool off. The three small lights near the whirlpool floor will remain illuminated until the keypad goes into sleep mode.
1042760-5-D 6 Kohler Co.
Operation (cont.)
Repeat the steps above to verify the second keypad is operating properly, less the chromatherapy functions.
NOTE: The whirlpool will automatically shut off approximately 20 minutes after continuous operation. If desired, press the power icon to reactivate the whirlpool.
Care and Cleaning
For best results, keep the following in mind when caring for your KOHLER product:
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
Wipe surfaces clean and rinse completely with water immediately after applying cleaner. Rinse and dry any overspray that lands on nearby surfaces.
Do not allow cleaners to soak on surfaces.
Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring pad to clean surfaces.
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care & Cleaning information, call 1-800-456-4537.
Flush System
NOTE: Flush your whirlpool system twice a month or more, depending upon usage.
Turn the jet trim rings fully clockwise to remove air induction.
Fill the whirlpool with warm water above the backjet level probes or leave water in the whirlpool after using.
Add 2 teaspoons (10 ml) of a low-foaming, powder automatic dishwasher detergent and 20 ounces (590 ml) of household bleach (5% - 6% sodium hypochlorite) to the water.
Run the whirlpool for 5 to 10 minutes. Turn off the whirlpool and drain the water. If desired, rinse the bath surfaces with water. Rinse the surfaces of the jets, faucet, handrails, and drain, and wipe them dry with a soft cloth.
Warranty
ONE-YEAR LIMITED WARRANTY
KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of installation.
Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, or by calling 1-800-4KOHLER (1-800-456-4537) from within the USA and Canada, and 001-877-680-1310 from within Mexico.
IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how
long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province.
This is Kohler Co.’s exclusive written warranty.
Kohler Co. 7 1042760-5-D
Warranty
KOHLER CO. It is recommended that at the time of purchase, you verify that all accessories and components are complete
in this package. This Kohler product is warranted to be free of defects in material and workmanship for one (1) year from the
date of purchase as shown on the invoice or receipt.
1. Kohler Co. will only service its commercialized products through its authorized distributors.
2. To obtain warranty service, please present the invoice and corresponding warranty.
3. Through its authorized distributors, Kohler Co. promises to repair the defective product or provide a new replacement or an equivalent model (in those cases that the model has been discontinued) when the product is beyond repair, without any charge to the consumer.
4. The time of repair will not exceed six (6) weeks commencing on the date the product is received.
5. It is recommended that the consumer save the invoice or receipt as additional protection, as it may substitute the warranty in the case that there is a discrepancy in the validity of the warranty.
EXCEPTIONS AND RESTRICTIONS The Warranty will not be valid in the following cases:
1. When the product is not operated in accordance with the instructions concerning use and operation set forth in the owner’s manual or installation instructions, and when the recommendations and warnings included are not observed.
2. When the product has been modified or dismantled partially or totally; or has been used in a negligent fashion and as a consequence has suffered damages attributable to the consumer, individual, or hardware not authorized by Kohler Co.
3. This warranty does not cover the damages as a result of disaster such as fire or acts of God, including flooding, earthquake, or electric storms, etc. To obtain a list of distributors in your area where you can exercise your rights under this warranty, please call 001-877-680-1310.
KOHLER CO., KOHLER, WI 53044 U.S.A.
IMPORTER:
INTERNACIONAL DE CERÁMICA, S.A.B. DE C.V. AV. CARLOS PACHECO NO. 7200 CHIHUAHUA, CHIH., MEXICO C.P. 31060 TEL: 52 (14) 29-11-11
Troubleshooting
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor.
1042760-5-D 8 Kohler Co.
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
1. User keypad does not
illuminate when power button is pressed or outer ring is rotated.
2. Motor starts, but all jets
are not functioning.
3. User keypad is
illuminated, but does not respond to buttons or outer ring.
4. User keypad indicator bar
keeps scanning at power-up.
5. User keypad is
illuminated, but pump will not start.
6. Motor runs but pump will
not prime (cavitates).
A. No power to control. A. Check wiring and connect power. If
B. GFCI or RCD tripped. B. Reset GFCI or RCD. C. Wiring harness from user
keypad to control is loose, disconnected, or damaged.
D. User keypad does not work. D. Replace user keypad. Refer to the
E. Control does not work. E. Replace control. Refer to the
A. Jet is closed. A. Rotate jet trim counterclockwise to
B. Jet not installed correctly. B. Reinstall jet; check for O-ring
C. Jets are blocked. C. Remove blockage. A. Control program is locked. A. Reset GFCI or RCD. B. Wiring harness from user
keypad to control is loose, disconnected, or damaged.
C. User keypad does not work. C. Replace user keypad. Refer to the
D. Control does not work. D. Replace control. Refer to the
A. Control program is locked. A. Reset GFCI or RCD. B. Wiring harness from user
keypad to control is loose, disconnected, or damaged.
C. User keypad does not work. C. Replace user keypad. Refer to the
D. Control does not work. D. Replace control. Refer to the
A. Power cord from pump to
control is loose, disconnected, or damaged.
B. Pump does not work. B. Replace pump. Refer to the
C. Control does not work. C. Replace control. Refer to the
A. Motor/Pump is shimmed too
high.
B. Small air leak at pump inlet. B. Securely tighten nut(s) on intake
C. Motor/pump does not work. C. Replace motor/pump. Refer to the
D. Control does not work. D. Replace control. Refer to the
problem persists, Refer to the installer/dealer.
C. Check wiring for proper
connections. Replace wiring harness if necessary. Refer to the installer/dealer.
installer/dealer.
installer/dealer.
open.
damage.
B. Check wiring for proper
connections. Replace wiring harness if necessary. Refer to the installer/dealer.
installer/dealer.
installer/dealer.
B. Check wiring for proper
connections. Replace wiring harness if necessary. Refer to the installer/dealer.
installer/dealer.
installer/dealer.
A. Check wiring for proper
connections. If problem persists, Refer to the installer/dealer.
installer/dealer.
installer/dealer.
A. Lower pump/control to subfloor
level.
side of pump.
installer/dealer.
installer/dealer.
Kohler Co. 9 1042760-5-D
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
7. Pump stops before 18
minutes.
8. Pump does not
automatically stop after 22 minutes.
9. Pump will not turn off
when the power button on user keypad is pressed.
10. Pump operates but
variable speed feature does not work.
11. Bath water cools while
pump is operating.
12. Noisy operation. A. Pump banding straps have not
Remote control does not
13.
work or operates both pumps.
14. Lights near whirlpool
floor do not work.
A. GFCI or RCD tripped. A. Identify source of fault, and correct.
B. Suction is blocked. B. Remove obstruction. C. Jets are blocked. C. Remove blockage. D. Motor overheated and
protection device activated.
A. 20-minute timer inadvertently
disabled.
A. User keypad does not work. A. Replace user keypad. Refer to the
B. Control does not work. B. Replace control. Refer to the
A. Motor/pump does not work. A. Replace motor/pump. Refer to the
B. Control does not work. B. Replace control. Refer to the
A. Water temperature above 104°F
(40°C).
B. Heater is turned off on user
keypad.
C. Wiring from heater to control is
loose, disconnected, or damaged.
D. Heater does not work. D. Replace heater. Refer to the
E. Control does not work. E. Replace control. Refer to the
been cut.
B. Dry or dislodged jet O-ring
(squeal).
A. Batteries improperly installed or
dead.
B. Antenna on wiring harness is
damaged.
C. Remote control not
programmed correctly.
D. Remote control does not work. D. Replace remote control. E. Control does not work. E. Replace control. Refer to the
A. Wiring damage. A. Check for loose or damaged wires.
Reset GFCI or RCD.
D. Check for blockage at suction
and/or jets. Remove blockage and allow motor to cool.
A. See Service Manual.
installer/dealer.
installer/dealer.
installer/dealer.
installer/dealer.
A. Allow bath water to cool.
B. Turn heater on.
C. Check wiring for proper
connections. Refer to the installer/dealer.
installer/dealer.
installer/dealer.
A. Cut pump banding straps with tin
snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
A. Replace batteries.
B. Replace wiring harness. Refer to
the installer/dealer.
C. See Homeowners Guide or Service
Manual.
installer/dealer.
Repair or replace as needed.
Chromatherapy Lights
Symptoms Probable Causes Recommended Action
1. Chromatherapy lights do
not work.
Backjet System
1042760-5-D 10 Kohler Co.
A. Loose, disconnected, or
damaged wiring/connections.
B. Control does not work. B. Replace control. Refer to the
A. Check wiring for proper
connections. Replace wiring if necessary. Refer to the installer/dealer.
installer/dealer.
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
1. Backjets do not operate. A. Whirlpool pump is not
A. Turn on pump.
operating.
B. Backjet butterfly valve does not
open.
B. Check for loose connections or
wires leading from the backjet pulse canister to the control. Replace the backjet pulse canister or control if necessary. Refer to the installer/dealer.
C. Not enough water in whirlpool. C. Fill whirlpool so water level
sensors.
D. Actuator switch does not work. D. Replace the actuator switch. Refer
to the installer/dealer.
E. Power from the pump motor to
the control is off.
E. Check for loose connections or
wires leading from the pump motor to the control. Refer to the installer/dealer.
F. Backjet pipe is blocked. F. Remove blockage. G. Switch wire from switch to
control is disconnected.
G. Reconnect or replace switch wires
that use a modular plug. Refer to the installer/dealer.
2. Backjets do not pulse. A. Pulse canister does not work. A. Check for loose connections or
wires leading from the pulse canister control. Replace the pulse canister or control if necessary. Refer to the installer/dealer.
B. Switch does not work. B. Replace the switch. Refer to the
installer/dealer.
C. Switch wire from the switch to
the control is disconnected.
C. Reconnect or replace the switch
wires that the modular plug. Refer to the installer/dealer.
Effervescence Ports
Symptoms Probable Causes Recommended Action
1. Effervescence ports do not
work.
A. Whirlpool pump is not
operating.
A. Turn on pump.
B. Butterfly valve does not open. B. Replace the butterfly valve. Refer
to the installer/dealer.
C. Pump does not work. C. Refer to the Service Manual to
troubleshoot the system. Refer to the installer/dealer.
D. Control does not work. D. Replace the control. Refer to the
installer/dealer.
2. Effervescence ports do not
bubble.
A. Air intake on the suction line is
blocked.
A. Remove blockage.
B. Water flow is too low. B. Increase the water flow.
Kohler Co. 11 1042760-5-D
A
B
**Finish/color code must be specified when ordering.
Service Parts
1042760-5-D 12 Kohler Co.
A
1023292
Cap
1-1/2" Tubing
*Note: All tubing 1" unless otherwise noted.
In-line Heater
1-1/2" Tubing
1/2" Tubing
1/2" Tubing
1/2" Tubing
3/4" Tubing
94528
Check Valve
1/2" Tubing
95462**
Pillow
1-1/2" Tubing
1049953
Lens
1049954
Nut
1048233
LED Lighting Harness
1-1/4" Tubing
1015019
Plug/Wire Assembly
1048232
Plug/Wire Assembly
1-1/4" Tubing
1-1/2" Tubing
**Finish/color code must be specified when ordering.
Kohler Co. 13 1042760-5-D
B
*Note: All tubing 1" unless otherwise noted.
1/2" Tubing
1-1/2" Tubing
94528
Check Valve
1/2" Tubing
1/2" Tubing
1/2" Tubing
1-1/2" Tubing
1-1/4" Tubing
1-1/4" Tubing
In-line Heater
1023292
Cap
3/4" Tubing
1-1/2" Tubing
1-1/4" Tubing
1-1/4" Tubing
1015019
Plug/Wire Assembly
1015012
Plug/Wire Assembly
**Finish/color code must be specified when ordering.
1042760-5-D 14 Kohler Co.
1003065
Suction Flange Removal Tool
93836 (1/2") 93837 (3/4") 93838 (1") 93839 (1-1/4") 94853 (1-1/2")
Tube (w/Couplings)
65054**
Screw
65226**
Suction Cover Plug
96708
Flange
73518
Plug
96895** 65061**
Cover
65886 60050
Gasket
(Colored Finishes) (Metal Finishes)
91967
Check Valve
93685
Housing
(Acrylic and FRP) (Cast Iron)
1086350
Flange Removal Wrench
67429
Flange
34353
O-Ring
67665
Plug
Single Jet For Whirlpools With 5 or Less Jets
88532**
(Colored Finishes)
88531**
1045715-P
Silicone Lube Packet
(Metal Finishes)
Jet
Single Jet For Whirlpools With 6 or More Jets
88530**
30739
Jet Tool
**Finish/color code must be specified when ordering.
(Colored Finishes)
88529**
(Metal Finishes)
Jet
67889
Jet Housing
65885 (Acrylic and FRP) 67668 (Cast Iron)
Gasket
Kohler Co. 15 1042760-5-D
67065
Ground Lug
61776
Lock Washer
61845-K
Copper Grounding Wire
1080775
Pump Tee
60320
Screw
94821
O-Ring
94821
O-Ring
1080774
Union Assy
93893
Cover
1033678
Screw
93892-A
Electrical Box
60320
Screw
To Tee Heater
61776
Lock Washer
67065
Ground Lug
93003
Strain Relief
1018964
Bracket
90153
Locknut
1019432
Carriage Bolt
90154
Locknut
1019719
Connector
1012855
Nut
1016957
Pump
1010676
Cover
1010677
Screw
94821
O-Ring
To In-line Heater
1010548
Volute
1016958
Motor
1010673
Seal
1016960
Impeller
1010675
O-Ring
1019444-A [3/4" (1.9 cm)] 1019444-B [1-3/4" (4.4 cm)] 1019444-C [2" (5.1 cm)] 1019444-D [1-1/2" (3.8 cm)] 1019444-E [1" (2.5 cm)] 1019444-F [1-1/4" (3.2 cm)] 1019444-G [2-1/4" (5.7 cm)] 1019444-H [2-1/2" (6.4 cm)] 1019444-J [2-3/4" (7 cm)] 1019444-K [3" (7.6 cm)] 1019444-L [1/2" (1.3 cm)] 1019444-M [1/4" (6 mm)]
Spacer
1019445-A [1-3/4" (4.4 cm)] 1019445-B [2-3/4" (7 cm)] 1019445-C [3" (7.6 cm)] 1019445-D [2-1/2" (6.4 cm)] 1019445-E [2" (5.1 cm)] 1019445-F [2-1/4" (5.7 cm)] 1019445-G [3-1/4" (8.3 cm)] 1019445-H [3-1/2" (8.9 cm)] 1019445-J [3-3/4" (9.5 cm)] 1019445-K [4" (10.2 cm)] 1019445-L [1-1/2" (3.8 cm)] 1019445-M [1-1/4" (3.2 cm)]
Stud
1018661 1018663
Control
**Finish/color code must be specified when ordering.
(One Outlet) (Two Outlets)
Outlet
1019447-A [1/4" (6 mm)] 1019447-B [1/2" (1.3 cm)] 1019447-C [3/4" (1.9 cm)]
Isolation Mount
1042760-5-D 16 Kohler Co.
1022408
In-line Heater
1032545
Housing
1012653
Adapter
1012653
Adapter
94821
O-Ring
1012916
Nut w/Screws
1018710
Tee Heater
94821
O-Ring
1011679
Gasket
1012977
Adapter
1012977
Adapter
94821
O-Ring
1012916
Nut with Screws
1011679
Gasket
**Finish/color code must be specified when ordering.
94821
O-Ring
Kohler Co. 17 1042760-5-D
93841
Screw
1019933
Chromatherapy Lights
1010618
Elbow
1012821
Light Housing
Effervescence Ports
1001878
Housing
93315
Gasket
93552**
Flange Cap
1035480**
Flange
**Finish/color code must be specified when ordering
96744
Flange Removal Tool
1042760-5-D 18 Kohler Co.
1080774
Union Assy
94821
O-Ring
1023753
Butterfly Valve
96956
Butterfly Kit
63149
Screw
1016466
Motor
50506
Screw
94821
O-Ring
1080774
Union Assy
**Finish/color code must be specified when ordering.
Kohler Co. 19 1042760-5-D
1023381
Wrench
Carefully study decal and cover detail below for proper service part identification.
1013452**
Dial Trim
1013453
Spring
1020677
Gasket
65157
Nut
1013499
Housing
91639
O-Ring
1020678-A
Cover/Circuit Board (w/Wrench)
1020678-C
Cover/Circuit Board (w/Wrench)
1020678-E
Cover/Circuit Board (w/Wrench)
1020678-N
Cover/Circuit Board (w/Wrench)
1013497-A
Decal
1013497-C
Decal
1013497-E
Decal
91639
O-Ring
91639
O-Ring
91639
O-Ring
1020678-B
Cover/Circuit Board (w/Wrench)
1020678-D
Cover/Circuit Board (w/Wrench)
1020678-M
Cover/Circuit Board (w/Wrench)
1020678-P
Cover/Circuit Board (w/Wrench)
1013497-B
Decal
1013497-D
Decal
1013497-M
Decal
91639
O-Ring
91639
O-Ring
91639
O-Ring
91639
1013497-N
Decal
**Finish/color code must be specified when ordering.
O-Ring
1013497-P
Decal
91639
O-Ring
1042760-5-D 20 Kohler Co.
Loading...