Kohler K-1015, K-1016, K-5161-L, K-1000, K-1005 Installation Instructions Manual

...
BODYSPA
PERSONAL HYDRO-MASSAGE SYSTEM
K-1000, K-1015/16, K-5161-L
This BodySpa operates at flow rates up to 80 gallons per minute. To achieve a watertight installation, it is critical
that you follow all the installation instructions carefully. Pay particular attention to leveling and sealing details to obtain a satisfactory installation.
IMPORTANT INFORMATION
WARNING: When using electrical products, basic precautions should always be followed, including the following:
DANGER: Risk of electrical shock. Connect only
to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).
Grounding is required. The unit should be installed and grounded by a qualified service representative.
Building materials and wiring should be routed away from the pump body and other heat-producing components of the unit.
10-JET ALCOVE
Install to permit access for servicing.
TABLE OF CONTENTS
PRODUCT NOTICES 2. . . . . . . . . . . . . . . . . . . . . . . . .
PRODUCT REQUIREMENTS 2. . . . . . . . . . . . . . . . . .
SITE REQUIREMENTS 3. . . . . . . . . . . . . . . . . . . . . . . .
BEFORE INSTALLING FOOTBATH 4. . . . . . . . . . . . .
INSTALL THE FOOTBATH 4. . . . . . . . . . . . . . . . . . . . .
BEFORE INSTALLING TOWER 7. . . . . . . . . . . . . . . . .
ELECTRICAL CONNECTIONS 9. . . . . . . . . . . . . . . . .
INSPECT CONNECTIONS 9. . . . . . . . . . . . . . . . . . . . .
DOOR ENCLOSURE PREP ARATION 10. . . . . . . . . . .
INST ALL THE ENCLOSURE 10. . . . . . . . . . . . . . . . . . .
INSTALL THE TOWER 19. . . . . . . . . . . . . . . . . . . . . . . .
COMPLETE INSTALLATION 21. . . . . . . . . . . . . . . . . . .
INSTALL THE SEAT 23. . . . . . . . . . . . . . . . . . . . . . . . . . .
WATER TEST FOOTBATH AND TOWER 23. . . . . . . .
CLEAN-UP AFTER INSTALLATION 23. . . . . . . . . . . . .
CONFIRM PROPER OPERA TION 24. . . . . . . . . . . . . .
116290-2-AB
2001 Kohler Co.
1. PRODUCT NOTICES
A. INST ALLER HAZARD NOTIFICA TION
WARNING: Risk of electrical shock. A licensed
electrician should make all electrical connections. WARNING: Risk of electrical shock. Connect only
to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).
WARNING: Risk of electrical shock. Disconnect power before servicing.
WARNING: Risk of injury or property damage.
Please read all instructions thoroughly before beginning installation, including the following Product Requirements.
NOTICE: Follow all local plumbing and electrical codes.
C. PRODUCT MODIFICA TIONS
All information in this manual is based upon the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice.
WARNING: Unauthorized modification may cause unsafe operation and poor performance of the BodySpa. Do not relocate the pump or make
other modifications to the BodySpa system, as this could adversely affect the performance and safe operation of the unit. Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification.
B. FACT ORY -ASSEMBLED FEA TURES
Factory installed components include pump with integral heater, control, and power supply cord.
The pump and piping are factory-assembled.
The BodySpa is not designed for steam applications, and may not perform satisfactorily as a steam unit.
2. PRODUCT REQUIREMENTS
A. PRODUCT INSPECTION
The BodySpa door enclosure, footbath, and tower are specifically designed for this installation. Before proceeding with the installation, check the model numbers of the footbath, tower, and door enclosure. The door enclosure, tower, and footbath model numbers are provided in the roughing-in information packed with the product.
Carefully unpack and inspect the footbath and tower for damage. Do not unpack the door enclosure until instructed to do so. Leave all materials in the cartons during construction to prevent damage.
NOTICE: Make sure the union connection to the pump inlet is securely tightened.
B. CONNECTIONS AND SERVICE ACCESS
Before installation, ensure proper access to the final connections.
NOTICE: Provide unrestricted service access to the pump. An access panel must be constructed to allow for
sufficient clearance for servicing the pump or controls. The access panel must be located immediately next to the pump. Refer to the roughing-in information packed with the product and the stud framing preparation on Page 3.
116290-2-AB
2
Kohler Co., Kohler WI U.S.A.
C. ELECTRICAL REQUIREMENTS
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI). The GFCI protects against line-to-ground shock hazard. Use a 120 V, 20 A, 60 Hz dedicated service for the BodySpa.
3. SITE REQUIREMENTS
A. CLEARANCE REQUIREMENTS
The distance from the rough floor to the finished ceiling or header must be between 83-1/2” and 84” to provide adequate clearance when assembling the door enclosure to the footbath. Be sure the ceiling and header are level.
B. STUD POCKET PREP ARA TION
NOTE: Carefully study the illustration at right before you
begin construction of the stud pocket. Follow the framing details provided to ensure correct installation.
Use 2x6 framing for the tower wall to provide sufficient space for the tower mounting frame and wiring, and minimum 2x4 framing for the rest of the stud pocket. Make sure you allow for access to the pump in the event the BodySpa requires service.
Provide double stud support for the door enclosure wall jambs. You must secure the door enclosure wall jambs directly to the studs to obtain proper support and correct opening dimensions. Expanding wall anchors will not provide adequate support for the door enclosure assembly.
You must install these stud supports to be within 3/8” of plumb for proper door enclosure installation. Maintain this tolerance to ensure a satisfactory, watertight installation.
The footbath requires no additional bottom support when the rough floor is plumb and level with respect to the stud framing. If the rough floor is not level, shim it as needed.
Verify that the distance from the rough floor to the finished ceiling is between 83-1/2” and 84”.
15-11/16”
31-7/8”
DOUBLE STUD (REQUIRED FOR ENCLOSURE INST ALLATION)
54”
16”
PROVIDE ACCESS TO DRAIN
2x6 STUDS
9-3/4” 12”
PUMP/ CONTROL ACCESS
DOUBLE STUD (REQUIRED FOR ENCLOSURE INST ALLATION)
83-1/2” to 84”
IMPORTANT: Leave studs exposed. You must secure the door enclosure wall jambs directly to the studs. Under no circumstances install the finished wall material until instructed.
If grab bars will be installed, provide backing to the framing.
C. PLUMBING PREP ARA TION
Position the plumbing according to the roughing-in dimensions. Cap the supplies, and check for leaks.
Kohler Co., Kohler WI U.S.A.
10-3/4”
ROUGH FLOOR
3
116290-2-AB
4. BEFORE INSTALLING FOOTBATH
Install the drain to the footbath according to the drain manufacturer’s instructions. When installing the drain overflow tube and hood, be sure to adequately seal along the edges of the hood to prevent leakage.
5. INSTALL THE FOOTBATH
A. CONFIRM STUD POCKET ROUGH-IN
The door enclosure is specifically designed for this footbath. For proper installation, make sure the double studs for the wall jambs are in position before installing the unit. Proper door enclosure assembly depends upon installation of the footbath against square and plumb (to within 3/8”) studding. Verify this before proceeding with the installation.
B. INST ALL THE FOOTBA TH
1. The variable flow valve assembly is attached to the suction line of the footbath harness for shipping, and the wires are connected to the pump. Cut the strapping, and remove the variable flow valve assembly. Remove and discard the plug on the end of the pump union. Then temporarily connect the variable flow valve to the pump by loosely threading the union nut to the pump discharge union.
2. Set the footbath on the subfloor. Align the trap with the tailpiece.
Variable Flow V alve Assembly
Pump
3. Position a clean drop cloth in the footbath to prevent damage.
4. Level the unit using the footbath rim surfaces. Do not use the nailing-in flange to level the unit. The footbath must be level to properly install and operate the door enclosure.
5. Securely shim under the wood blocks as needed. Secure the footbath to the studding using the nailing-in flange and galvanized drywall screws. Drill and countersink pilot holes halfway up the nailing-in flange. Drill from the finished side of the nailing-in flange to prevent chipping of the acrylic.
6. Add furring strips to the stud framing inside the recess area. This will make the studs even with the footbath nailing-in flange.
Nailing-In Flange
116290-2-AB
4
Kohler Co., Kohler WI U.S.A.
C. CONSTRUCT THE APRON
NOTE: Kohler Co. recommends this procedure for
constructing a BodySpa apron. Other methods can be used to obtain an acceptable result.
1. Cut four 3/4” plywood boards to 6” x 34-1/4”. Measure and cut a 55 taper at one end of each board, and a 75 taper at the other end. Both ends must taper to the same side.
5”
34-1/4”
75 55
6”
2. Draw a pencil mark 3” from the long side of one of the boards at the 75 taper end. Draw a second mark 5” from the long side, as shown.
3. Use a pencil, string, and nail to carefully draw a 51-1/4” radius (for 1/2” thick finished wall) across the full length of the board at the 3” pencil mark. For different finished wall thickness, adjust this radius accordingly. Draw a 49-1/4” radius across the 5” pencil mark.
4. Use a saber saw to cut the plywood along the radius lines.
5. Use this board as a template to mark and cut the other three plywood boards.
6. Cut four 3/4” plywood boards to 2” x 6”, with a 50 taper on one end.
7. Cut twelve 2x2 studs 9” long.
8. Assemble the apron frame sections as shown.
3”
2x2 Studs
51-1/4” R.
49-1/4” R.
2”
3/4” Plywood
Measure 3” and 5” Down From This Edge
6”
50
9. Position the apron frame sections under the footbath rim so the 75 tapered ends of the curved sections touch. Align the apron frame sections so they are recessed correctly for the finished apron wall thickness. Make sure the sections are plumb.
10. Secure the apron frame sections to the floor.
9”
10-1/2”
3/4” Plywood
Kohler Co., Kohler WI U.S.A.
5
116290-2-AB
D. TOWER MOUNTING FRAME PREP ARA TION
On one of the tower mounting studs, draw a pencil line exactly 2-3/8” up from the flat surface of the seat deck. Y ou will use this mark to position the tower mounting frame at the correct height. Be precise with this measurement.
2-3/8”
E. PUMP BANDING STRAP CUT
NOTICE: This step is necessary to make your Kohler BodySpa operate more quietly.
Use tin snips to cut the banding strap. When the banding strap is cut, the pump base and pump will continue to rest upon the plywood ledge that extends from under the footbath.
F . INST ALL PLUMBING
CAUTION: Risk of damage to footbath bottom and subfloor. Ensure a watertight seal on the
footbath drain connections.
When the footbath is securely positioned, connect and leak test the drain and fittings.
NOTE: An access panel will simplify future maintenance.
Pump
Suction Line
Banding Strap
Pump Base
Plywood Ledge
Subfloor
Connect Here
116290-2-AB
6
Kohler Co., Kohler WI U.S.A.
6. BEFORE INSTALLING TOWER
A. INST ALL THE MOUNTING FRAME
Remove three 3/8” tower bolts from the locations shown, and carefully lift the tower out of the mounting frame. Carefully set the tower aside where it will not be damaged.
Set the mounting frame between the tower mounting studs, and line up the bottom metal edge with the pencil line you drew on one of the studs.
Secure the mounting frame to the tower mounting studs with ten stainless steel drywall screws provided.
Mounting Stud
Mounting Frame
Pencil Line
Bolts
Bolt
Stainless Steel Drywall Screw
Kohler Co., Kohler WI U.S.A.
7
116290-2-AB
B. INSTALL CABLE USING OUTLET BOX
Stud
NOTE: If the desired keypad location does not permit you to secure the provided outlet box directly to a stud, you can route the control cable directly through the wall material without using an outlet box. Proceed to Step C. to install the keypad without an outlet box.
Plug the control cable into the right jack of the control box. Position the supplied outlet box inside the enclosure at the
chosen control mounting location so the metal plate (not shown) will be flush with the finished wall or slightly recessed when installed. Install the outlet box so the 10’ control cable is within reach of the control box. Do not stretch or pull on the control cable. Install the outlet box 58” to 60” up from the floor of the footbath.
Secure the outlet box to the nearest stud. Route the control cable from the control box to the outlet
box, and insert the loose connector into the knockout hole in the outlet box. Create a drip loop in the cable.
NO
TE: National Electrical Code requires that you
permanently separate the high- and low-voltage cables.
Outlet Box
Outlet Box
SIDE VIEW
Control Box
Stud
Drip Loop
58” To 60” From Floor
Control Cable
C. INST ALL CABLE WITHOUT OUTLET BOX
Plug the control cable into the right jack of the control box. Route the control cable directly through the large hole in the center of the metal plate. Temporarily tape together the control cable and the metal plate. Also tape the two screws to the metal plate to prevent them from becoming lost. Create a drip loop in the cable to prevent water from following the cable down to the control box.
Temporarily secure the control cable and metal plate to the stud nearest your chosen keypad mounting location. Position the metal plate 58” to 60” up from the floor of the footbath.
Leave the control cable and metal plate attached here until the finished wall is constructed. At that time, the metal plate will be permanently attached flush to the outside surface of the finished wall with two screws. The control cable will then be secured to the metal plate with a cable tie looped between the large and small center holes in the metal plate.
NO
TE: National Electrical Code requires that you
permanently separate the high- and low-voltage cables.
Metal Plate
Control Cable
Drip Loop
Control Cable
To Metal Plate
Control Box
116290-2-AB
8
Kohler Co., Kohler WI U.S.A.
D. CONNECT VARIABLE FLOW V AL VE
ASSEMBL Y TO PUMP
Loosen the variable flow valve assembly by unthreading the union nut. Reposition the variable flow valve assembly so the outlet union lines up with the mounting frame union nut. Securely handtighten the union nut. Be sure the union O-ring is in place. Do not apply sealant to the union.
Handtighten the mounting frame union nut to the variable flow valve union. Be sure the union O-ring is in place. Do not apply sealant to the union.
Mounting Frame
7. ELECTRICAL CONNECTIONS
WARNING: Risk of electrical shock. To reduce
the risk of electric shock, connect only to a properly grounded, grounding-type receptacle, protected by a Ground-Fault Circuit-Interrupter (GFCI). Do not remove the plug’s grounding pin. Do not use a grounding adapter.
The Kohler BodySpa is equipped with a cord and plug. All wiring of the pump and control has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 20 A, grounded outlet. The BodySpa may then be plugged into this outlet. No other load should be on this circuit. Locate the outlet behind the BodySpa, and within 24” of the pump.
Variable Flow V alve Assembly
Pump
Bonding (Earthing) Lug*
Plug-in Cord
Pump
Mounting Frame Union Nut
BACK VIEW
20 A Receptacle
* For bonding in accordance with national and local codes.
8. INSPECT CONNECTIONS
Check all electrical connections. Open the hot and cold water valves, and check all supply
connections for leaks. Fill the footbath to the overflow, and check the overflow and drain connections for leaks.
Kohler Co., Kohler WI U.S.A.