IMPORTANT INFORMATION
WARNING: Risk of personal injury or product damage. Handle with care.
Vitreous China can break or chip if the bolts and nuts are over-tightened, or if the product is handled carelessly.
FOLIO
INSTALLATION INSTRUCTIONS
K-2018IN-1WH / K-2017IN-1 / K-11341IN-1
VITREOUS CHINA LAVATORY
Observe all local plumbing and building codes.
Carefully inspect the new lavatory & pedestal for any damage.
Consumer should preserve this document to order spare parts in future.
TOOLS & MATERIALS REQUIRED
A. Spirit Level
B. 10" Adjustable Wrench
C. Hammer Drill with 14mm Drill Bit
Refer Figure 1
ORDERING INFORMATION
Folio WM Lavatory, Single Hole .............................................K-2018IN-1WH*
Folio Full-Ped Lavatory, Single Hole.......................................K-2017IN-1*
Includes Folio Pedestal................................................K-2019IN*
Includes Folio WM Lavatory, Single Hole......................K-2018IN-1WH*
* Available in “-0 (White)” & “-96 (Biscuit)”
ROUGHING-IN
2
For Wall-Mount Lavatory Installation
(K-2018IN-1WH*)
24"
(61.0 cm)
18-7/8"
(48.0 cm)
3" (7.6 cm)
7-3/4"
(19.7 cm)
For Full-Pedestal Lavatory Installation
(K-2017IN-1*)
18-7/8"
(48.0 cm)
Folio Half-Ped Lavatory, Single Hole....................................K-11341IN-1*
Includes Folio Half-Pedestal......................................K-11340IN*
Includes Folio WM Lavatory, Single Hole...................K-2018IN-1WH*
24"
(61.0 cm)
1
3" (7.6 cm)
7-3/4"
(19.7 cm)
C
A
B
For Half-Pedestal Lavatory Installation
(K-11341IN-1*)
24"
(61.0 cm)
18-7/8"
(48.0 cm)
3" (7.6 cm)
(19.7 cm)
7-3/4"
8-11/16"
2-3/8"
(6.0 cm)
9-1/4"
(23.5 cm)
16"
(40.5 cm)
ŸAll dimensions in inches (cm). Fixture dimensions are nominal and conform to tolerances as per ASME Standard A112. 19.2M.
ŸProduct illustrations shown are representative only; actual products may vary.
ŸKohler reserves the right to make changes in product characteristics, packaging or availability at any time without notice.
CAUTION : Do not use cement or high lime content cement to install the lavatory. The expansion of lime/cement due to rise in temperature may cause the lavatory to
crack or be damaged.
(22.0 cm)
1/2" Hot
Anchor Holes
(23.5 cm)
1/2" Cold
4" (10.2 cm)
1-1/4" (3.2 cm)
Waste Outlet
Kohler is not responsible for any damage caused by installation with the use of Lime/ Cement.
34-1/4"
(87.0 cm)
(40.5 cm)
2-3/8"
(6.0 cm)
9-1/4"
16"
8-11/16"
(22.0 cm)
1/2" Hot
Anchor Holes
1/2" Cold
4" (10.2 cm)
1-1/4" (3.2 cm)
Waste Outlet
34-1/4"
(87.0 cm)
2-3/8"
(6.0 cm)
9-1/4"
(23.5 cm)
1/2" Hot
16"
(40.5 cm)
8-11/16"
(22.0 cm)
7-1/2"
(19.0 cm)
Anchor Holes
1/2" Cold
4" (10.2 cm)
1-1/4" (3.2 cm)
Waste Outlet
INSTALLATION GUIDELINE
1. Prepare the Site :-
• Rough-in the supplies & the drain piping. For dimensions, Refer Fig.#2.
• Install 1/2" water supply lines & 1-1/4" drain piping according to the roughing-in information.
• Install sufficient backing behind the finished wall to provide a secure material for the anchoring devices.
NOTE :- Please ensure that Angle-Valve handles do not extend beyond 76mm (3") from the finished wall when in open position. This will ensure the handles will not
touch the pedestal when fully open.
(87.0cm)
(72.3cm)
34-1/4"
28-1/2"
1232255-IN01-A
-1-

2. Installation of the Lavatory :-
WALL-MOUNT INSTALLATION (K-2018IN-1WH*)
1. Drill two 14mm Anchor holes, 76 mm deep
into the wall according to the Rough-in diagram.
2. Insert the plastic anchors (provided) in two
holes.
3. Insert the metal studs (provided) into these
plastic anchors using an adjustable wrench.
4. Ensure that at least 70 mm (approx.) of each
stud should remain exposed from the wall.
5. Install the faucet & drain to the lavatory
according to the manufacturer’s instructions.
NOTE :- Do not fully tighten slip-joint drain
connections at this time.
Refer Fig. #4
FULL-PEDESTAL INSTALLATION (K-2017IN-1*)
Ø
Refer Fig. #3
3
4
Metal Studs
Plastic Anchors
Carefully place the lavatory against the wall,
6.
so the metal studs extend through the
lavatory holes.
7. Level the lavatory.
8. Install the plastic washer & nut (provided)
& tighten suitably.
CAUTION : Risk of product damage.
Do not over tighten the nut. Over tightening
may cause damage to the product.
Use wrench to tighten 8-10 N-m/ 6-9 turns.
*
(1 turn = 45°) past finger tight.
Refer Fig. #5
9. Connect & tighten the bottle trap as per
manufacturer’s instructions. Connect the
hot & cold water supplies to the faucet.
10.Evenly p
ut the sealant around the mounting
surface of the lavatory touching the wall.
Refer Fig. #6
11.Clean the lavatory top.
5
Metal Studs
Plastic Washer
6-9 turns (45 ) allowed past finger tight ° each
6
10
Lavatory
Nut
45°
1. Apply self-adhesive leveling pads (provided)
to each of the three ridges in the bottom recess of the
lavatory.
Refer Fig. #7
2. Mark the centerline on the floor with a pencil & position
the pedestal on the floor centerline location.
Refer to the roughing-in dimensions for correct
placement.
3. Carefully set the lavatory on the pedestal & move the
pedestal as required to ensure proper fit in the desired
location.
NOTE :-The lavatory must be supported by the
pedestal.
4. Mark the center of each anchoring hole on the wall.
5. Carefully remove the lavatory from the pedestal. Then
move the pedestal from the area.
Refer Fig. #8
6. Drill two 14mm Anchor holes,
Ø 76 mm deep into the
wall at the marked location.
7. Insert the plastic anchors in two holes.
8. Insert the metal studs (provided) into these plastic
anchors using an adjustable wrench.
9. Ensure that at least 70 mm (approx.) of each stud
should remain exposed from the wall.
Refer Fig. #9
10.Install the faucet & drain to the lavatory according
to the manufacturer’s instructions.
7
8
Center of
Anchoring Holes
9
Metal Studs
Pedestal
Mark center
line Here
Plastic
Anchors
NOTE :- Do not fully tighten slip-joint drain
connections at this time.
Refer Fig. #10
Carefully place the lavatory against the wall,so the
11.
metal studs extend through the lavatory holes.
Install the washer and nut, Do not fully tighten the
nuts at this time for pedestal adjustment.
Refer Fig. #11
12. Connect & tighten the trap as per manufacturer’s
instructions. Connect the hot & cold water
supplies to the faucet.
13. Place the Pedestal with proper adjustment & level
the lavatory .Use additional self-adhesive leveling
pads as required to level the lavatory. Tighten the
nuts suitably.
CAUTION : Risk of product damage.
Do not over tighten the nut. Over tightening
may cause damage to the product.
Use wrench to tighten 8-10 N-m/ 6-9 turns.
*
(1 turn = 45°) past finger tight.
Refer Fig. #12
14. Evenly put the sealant around the mounting
surface of the lavatory touching the wall.
Refer Fig. #13
15. Clean the lavatory top.
Metal Studs
11
12
Center line
6-9 turns (45 ) allowed past finger tight ° each
13
Plastic Washer
Nut
Lavatory
Pedestal
45°
HALF-PEDESTAL INSTALLATION (K-11341IN-1*)
1. Apply self-adhesive leveling pads (provided) to each of
the three ridges in the bottom recess of the lavatory.
Refer Fig. #14
2. Mark the centerline on the wall with a pencil.
3. Mark the location of the mounting holes of the lavatory
according to the Roughing-In diagram.
4. Drill two Ø14mm Anchor holes, 76 mm deep into the
wall at the marked location.
5. Insert the plastic anchors in two holes.
6. Insert the metal studs (provided) into these plastic
anchors using an adjustable wrench.
7. Ensure that at least 70 mm (approx.) of each stud
should remain exposed from the wall
Refer Fig. #16.
8. Install the faucet & drain to the lavatory according
to the manufacturer’s instructions
NOTE :- Do not fully tighten slip-joint drain connections
at this time.
Refer Fig. #17
9. Place the Lavatory onto metal studs and install
the washer and nut, Do not fully tighten the nuts
at this time for pedestal adjustment.
Refer Fig. #18
14
15
16
Metal Studs
17
Mark center
Line Here
Plastic Anchors
10.Connect & tighten the trap as per manufacturer’s
instructions. Connect the hot & cold water
supplies to the faucet.
11. Place the Half-Pedestal beneath the lavatory
& mark the location of mounting holes of Pedestal.
12. Install the Half-Pedestal with suitable hard wares.
13. Level the lavatory .Use additional self-adhesive
leveling pads as required to level the lavatory.
14. Tighten the lavatory nuts properly to complete the
installation.
CAUTION : Risk of product damage.
Do not over tighten the nut. Over tightening
may cause damage to the product.
Use wrench to tighten 8-10 N-m/ 6-9 turns.
*
(1 turn = 45°) past finger tight.
Refer Fig. #19
15. Evenly put the sealant around the mounting
surface of the lavatory touching the wall.
16. Clean the lavatory top.
Refer Fig. #20
Metal Studs
18
19
Center line
6-9 turns (45 ) allowed past finger tight ° each
20
Plastic Washer
Nut
Lavatory
Pedestal
45°
* Installation doesn't allow use of any tool other than standard wrench. For this reason, split turns have been mentioned rather than full turns.
SERVICE PARTS (Supplied with the Product)
A. Hardware Kit 1213117
B. Levelling Pads 63069
Important Notice for Care, Cleaning & Daily use
To keep your lavatory looking new, make sure you rinse it out thoroughly after each use.
DO NOT USE ABRASIVES on this product, as they will scratch & ruin the surface.
Stubborn stains, paint, or tar can be removed with turpentine or paint thinner.