Kodak III Plus User manual

{InstallationInstructs}{Product ion}{HealthImaging}{ExternalA ndInternal}
INSTALLATION INSTRUCTIONS
for the
EXHAUST KIT
used with the
Kodak AUTOMIXER III PLUS
Service Code: 3402
Publication No. 4E9701
Catalog No. 129 0584
Important
Qualified service personnel must install this equipment.
HEALTH IMAGING
Confidential
Restricted Information
© Eastman Kodak Company, 2002
PLEASE NOTE The information contained herein is based on the experience and knowledge relating to the
subject matter gained by Eastman Kodak Company prior to publication. No patent license is granted by this information. Eastman Kodak Company reserves the right to change this information without notice, and
makes no warranty, express or implied, with respect to this information. Kodak shall not be liable for any loss or damage, including consequential or special damages, resulting from any use of this information, even if loss or damage is caused by Kodak’s negligence or other fault.
This equipment includes parts and assemblies sensitive to damage from electrostatic discharge. Use caution to prevent damage during all service procedures.
EXHAUST KIT 4E9696 includes:
Part No. Description Quantity
5E6831 Y- FITTING - 3 in. 2 5E6832 DAMPER GATE - 3 in. 2 4E9701 INSTALLATION INSTRUCTIONS 1
Note
You must purchase the following 2 items locally:
• EXHAUST DUCT
•CLAMPS
Necessary Tools
Part No. Description
TL-2431 AIR METER
Determining the Serial Number of the AUTOMIXER III PLUS
[1] Is the serial number of the AUTOMIXER III PLUS 120,100 or higher?
Yes No
Advance to Installing the EXHAUST KIT
on Page 5. Continue with Orde ring Neces sa ry Parts.
Ordering Necessary Parts
[1] Order the necessary parts from Service Parts Management.
Part No. Description Quantity
4E9326 COVER - evaporation 1 4E9757 PANEL - rear 1 468535 ADAPTER - exhaust 2 544194 SCREW - 6-32 x 1/2 in. 4 165627 WASHER 4 853096 LOCK WASHER 4 852620 NUT 4
2 06FEB02 – 4E9701
Warning
Dangerous Voltage
[2] De-energize the equipment. [3] Disconnect the equipment.
EVAPORATION COVER
AUTOMIXER III PLUS
H115_0102HCA H115_0102HC
[4] Is the PROCESSOR installed on the AUTO MIXER III PLUS?
Yes No
a. Drain the PROCESSOR.
Continue with Step 5
.
b. Carefully lift the PROCESSOR and place it
next to the AUTOMIXER III PLUS.
c. Continue with Step 5
.
[5] Install the new EVAPORATION COVER on top of the AUTOMIXER III PLUS.
4E9701 – 06FEB02 3
INSTALLATION INSTRUCTIONS
4 NUTS
4 LOCK WASHERS
4 WASHERS
REAR PANEL
[6] Install the new parts on the new REAR PANEL:
• 2 EXHAUST ADAPTERS
• 4 SCREWS
• 4 WASHERS
• 4 LOCK WASHERS
•4 NUTS
[7] Disconnect the existing REAR PANEL from the AUTOMIXER III PLUS. [8] Remove and discard the REAR PANEL.
[9] Install the new REAR PANEL. [10] Connect the new REAR PANEL. [11] Carefully lift the PROCESSOR and place it on top of the AUTOMIXER III PLUS.
2 EXHAUST ADAPTERS
4 SCREWS
H115_0104HCA
H115_0104HC
4 06FEB02 – 4E9701
Installing the EXHAUST KIT
DAMPER GATE
Y - FITTING
Y - FITTING
DAMPER GATE
EXHAUST DUCT
EXHAUST DUCT
EXHAUST DUCT
H115_0103DCA
H115_0103DC
Important
Do not fasten the EXHAUST DUCTS to the equipment now.
[1] Measure and cut EXHAUST DUCTS for the installation. [2] Connect the EXHAUST DUCTS. Use the new:
• Y-FITTINGS
• DAMPER GATES
[3] Use CLAMPS to fasten the EXHAUST DUCTS at the connections.
4E9701 – 06FEB02 5
INSTALLATION INSTRUCTIONS
Connecting the System
H150_0112HCA
H150_0112HA
EXHAUST DUCT for the Building
AUXILIARY VENTILATION FAN - Optional
5.08 cm (2.0 in.) maximum
EXHAUST DUCT for the PROCESSOR
L-TUBE
HOSE
CONNECTOR
AIR METER
EXHAUST DUCT that connects to the PROCESSOR
30.5 cm
(12.0 in.)
Important
• For optimum operation, the AUTOMIXER III PLUS and PROCESSOR must be connected to a system with the correct negative pressure. A negative pressure of 2.54 mm (0.10 in.) is recommended.
• If you cannot obtain the correct negative pressure, the customer must install an AUXILIARY VENTILATION F AN. See the SITE SPECIFICATIONS 5B6329.
[1] Check that the negative pressure is correct.
Size of the DUCT Negative Pressure
7.6 cm (3.0 in.) 0.76
2.54 mm (0.03 0.10 in.) of water
(a) Connect the rubber HOSE from the center CONNECTOR on the AIR METER TL-2431 to the L-TUBE. (b) Disconnect the EXHAUST DUCT at the PROCESSOR. (c) Make a 6.4 mm (0.25 in.) hole approximately 30.5 cm (12.0 in.) from the end of the 2 EXHAUST DUCTS
for the AUTOMIXER III PLUS and the EXHAUST DUCT for the PROCESSOR. These DUCTS are connected to the EXHAUST DUCT for the building.
(d) Insert the L-TUBE into the hole until the end of the TUBE is flush with the inside of the EXHAUST DUCT. (e) Hold the METER vertically and check that it indicates the correct negative pressure.
(f) If necessary, adjust the DAMPER GATES until the negative pressure is correct and equal for the 3
EXHAUST DUCTS.
(g) Remove the L-TUBE from the EXHAUST DUCT and adhere tape on the remaining holes.
[2] Connect the EXHAUST DUCTS to the AUTOMIXER III PLUS and the PROCESSOR.
6 06FEB02 – 4E9701
Publication History
Publication Date Publication No. ECO No. Changed Pages File Name Notes
20FEB02 4E9701 2655-012
--- 4e9701.fm New Publication
2655-013
4E9701 – 06FEB02 7
Printed in U.S.A. • 4e9701.fm
EASTMAN KODAK COMPANY Rochester, NY 14650
Kodak is a trademark.
HEALTH IMAGING
Loading...