Knight Equipment UP-1100VS Installation Manual

UP-1100VS / UPL-1100VS
Instruction Manual
Page 1 of 8 0901027 Rev: B (05/01)
7$%/(2)&217(176
Installation ..................................................................................................3
Pump Connection ......................................................................................3
Wiring Diagram ..........................................................................................5
Assembly Diagram ....................................................................................6
Warranty ....................................................................................................8
Knight Locations ........................................................................................8
CAUTION: The UP1100VS / UPL1100VS system has high voltage connected to the transformer. Always disconnect main power when servicing the unit.
0901027 Rev: B (05/01) Page 2 of 8
,167$//$7,21
(1) Mount the unit on a wall in a convenient location near the dishwasher and not more than three feet
from the final rinse line. A mounting bracket is available for mounting the unit on top of the dishwasher if desired.
(2) NOTE: Mounting the unit on the side, on the back, or on the vents of the dishwasher may cause
thermal overload and damage or hinder the performance of the unit. Do NOT mount the unit in the direct path of steam. This can short circuit and permanently damage the unit.
(3) Check the available input voltage of the unit. Application of incorrect voltage will permanently
damage the unit and is not covered under warranty. (4) Remove power from the dishwasher. (5) Connect power leads to the proper terminals on the wiring barrier. Wire the system in a manner that
will ensure that chemicals will be dispensed during the rinse cycle. Rigid or flexible conduit, installed
in accordance with local electrical codes, should be used to ensure safety and continued operation.
83963803&211(&7,216
(1) Install 1/4" tube x 1/8" NPT rinse injection fitting into the side or bottom of the dishwasher rinse line
between the rinse solenoid valves and the rinse jets. Drill a 11/32" hole and tap to 1/8" NPT. Use of a
saddle clamp may be desired on copper rinse line for better support. Saddle clamps can be used if
required. (2) Install 1/4" O.D. poly tubing between the discharge (right) tube side of the peristaltic pump and the
injection fitting using the 1/4" poly compression nuts. (3) Install 1/4" O.D. poly tubing between the suction (left) tube side and the pickup tube provided. Be
sure to draw tubing through the end of the pickup tube.
83/963803&211(&7,216
(1) Install chemical injection fitting into wall of the washtank. (2) Install discharge tubing between the discharge (right) side of the peristaltic chemical pump and the
chemical injection fitting. (3) Install suction tubing between suction (left) side of the peristaltic chemical pump and the pickup tube
provided. (4) Be sure to draw tubing through the end of the pickup tube.
Page 3 of 8 0901027 Rev: B (05/01)