Knight Equipment UDP-100S Installation Manual

UDP-100S / UPP-100S
Instruction Manual
Page 1 of 8 0901017 Rev:C (05/01)
TABLE OF CONTENTS
UDP-100S Installation ...............................................................................2
UDP-100S Pump Connections ..................................................................2
UPP-100S Installatiion ...............................................................................3
UPP-100S Pump Connections ..................................................................3
UPP-100S operation ..................................................................................3
Wiring Diagram ..........................................................................................9
Assembly Diagram ..................................................................................10
Warranty Information .................................................................................6
Knight Locations ........................................................................................6
CAUTION: The UDP /UPP Series system has high voltage connected to the transformeralwaysdisconnect main power when servicing the unit.
0901017 Rev:C (05/01) Page 2 of 8
UDP-100S INSTALLATION
(1) Mount the unit on a wall in a convenient location near the dishwasher, the DataPlus unit that will control the
UDP-100S, and not more than three feet from the final rinse line.
of the UDP-1000S to the top of the chemical container will be at least 12"
available for mounting the unit on top of the dishwasher if desired. NOTE: Mounting the unit on the side, on the back, or on the vents of the dishwasher may cause thermal overload and damage or hinder the performance of the unit. Do NOT mount the unit in the direct path of steam. This can short circuit and
permanently damage the unit. (2) Remove power from the DataPlus unit that will control the UDP-100S. (3) Install the 4-conductor cable from the UDP-100S to the DataPlus circuit board (see installation drawing).
Ensure that th e distance from the bottom
. A mounting bracket is
UDP-100S PUMP CONNECTIONS
(1) Install 1/4" tube injection fitting into the side or bottom of the dishwasher rinse line between the rinse solenoid
valves and the rinse jets. Drill a 11/32" hole and tap to 1/8" NPT. Use of a saddle clamp may be desired on
copper rinse line for better support. Saddle clamps can be used if required. (2) Install 1/4" O.D. poly tubing between the discharge (right) tube side of the peristaltic pump and the injection
fitting using the 1/4" poly compression nuts. (3) Install 1/4" O.D. poly tubing between the suction (left) tube side and the pickup tube provided. Be sure to
draw tubing through the end of the pickup tube.
UDP-100S OPERATION
Control of the pump will be performed by the DataPlus unit that the pump is connected to — refer to the DataPlus Programming Manual for detailed implementation instructions of the UDP-100S.
As a reminder, remember to remove the jumper over the LOW SAN terminals on the DataPlus board or the low level lights and alarms will NOT activate.