GENERAL SPECIFICATIONS
The Klein Tools CL200 is a multi-featured clamp meter. It measures AC / DC voltage, AC current, resistance, capacitance, frequency, duty cycle, and temperature. It can also test diodes and continuity.
• Operating Altitude: 2000 meters
• Relative Humidity: 75% max
• Operating Temperature: 0°C / 32°F to 40°C / 104°F
• Storage Temperature: -10°C / 14°F to 50°C / 122°F
• Accuracy Temperature: 18°C / 64°F to 28°C / 82°F
• Temperature Coefficient: 0.1*(specified accuracy) / °C
• Sampling Frequency: 3 samples per second
• Dimensions: 8.2" x 3.0" x 1.4"
• Weight: 10.0 oz.
• Calibration: Accurate for one year
®
For Professionals...Since 1857
• CAT Rating: CAT III 600V
• Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes are connected.
• Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
SYMBOLS
Visit us at www.TestEquipmentDepot.com
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
AC Alternating Current Warning or Caution
~
DC Direct Current Dangerous levels
DC/AC Voltage or Current Double Insulated Class II
Ground
AC Source
Safe for disconnect from live conductors
Page 2
ENGLISH
CL200
AUTO
A
AC
CL200
FEATURE DETAILS
H. Backlig ht / Worklight
• Hold button down to enable worklight and backlight.
• On release, lights will turn off automatically after 5 to 15 seconds.
• Worklight only operates during AC current measurement.
• Using lights drains the battery significantly.
Auto Power-Off
• Device will power off after 30 minutes non-use.
1
• Turn the dial or press a button to wake.
• Press the
HOLD
button while turning on to disable
Auto Power-Off feature.
H
B
G
On Back
FUNCTION INSTRUCTIONS
1
H C
3
D E
F
5
2
1. AC Current: < 600A
Features:
HOLD RANGE WORKLIGHT
4
A
A. Use CAT III rated leads or higher.
Do not attempt to measure more than 600V or
any current on lead input. B. Keep hands below line when measuring high current levels. C. Select Functionality Button
• Switch between AC and DC.
• Switch between
D. Data Hold
• Press to hold the current input on the display.
• Press again to return to live reading.
E. Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Hold for 2 seconds to return to auto ranging mode.
AUTO
•
F. G. Battery Replacement
• When batteries must be replaced.
• Remove the back screw and replace 3 x AAA batteries.
Ω, , , and .
is displayed on LCD only during auto ranging mode.
indicator is displayed on the LCD,
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
2. AC / DC Vol tage: < 600V
Features:
HOLD RANGE
PRESS
AUTO
AC
A
• Select AC or DC voltage source.
3. Freq uency (Hz) / Dut y Cy cle
Features:
HOLD
PRESS
Duty
AUTO
AC
A
Page 3
ENGLISH
4. Temperature: -4° ≤ °F ≤ 1832°
Features:
HOLD
AC
A
• Use included thermocouple.
5. Resis tance / Capac itance / Diode / Cont inuity
PRESS
TO SELECT
Resistance
Diode
Capacitance Continuity
AUTO
AC
A
Resistance Features:
HOLD RANGE
• Ω < 40MΩ
•
Do not measure resistance
on a live circuit.
AUTO
AC
A
Capacitance Features:
HOLD RANGE
• F < 100μF
• Wait up to 60 seconds for measurement.
•
Safely discharge capacitor before
measurement.
AUTO
AC
A
Diode Features:
HOLD
Display shows:
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
AUTO
AC
A
Continuity Features:
HOLD
• Display shows resistance.
• Buzzer sounds if less than 60Ω
SYMBOLS USED ON LCD
AC Measurement DC Measurement
~
Negative DC Value
-
Low Battery Hold Active Diode Test
H
Voltage Measurement Continuity Test
V
Frequency in Hertz
Hz
Capacitance in Farads
F
Resistance in Ohms
Ω
m
n
Milli 10 Nano 10
-3
-9
AUTO
Auto Range Active Current in Amps
A
Duty Cycle
%
Temperature in Fahrenheit
F
°
Mega 10
M
Kilo 10
k
μ
Micro 10
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
400mV 0.1mV 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.0% + 2 digits)
Overload Protection: 600V DC / AC Input Impedance: 10MΩ.
AC Voltage Measurement
Range Resolution Accuracy
400mV 0.1mV 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.2% + 10 digits)
Overload Protection: 600V DC / AC Frequency: 40 to 400Hz Input Impedance: 10MΩ. Response: Averaging
AC Current Measurement
Range Resolution Accuracy
4A 0.001A ± (3.5% + 20 digits) 4A 0.001A ± (3.0% + 10 digits) > 0.5A 40A 0.01A ± (3.0% + 10 digits) 400A 0.1A ± (2.5% + 10 digits) 600A 1A ± (1.5% + 5 digits)
Overload Protection: 720A for 60 sec. max Frequency: 50 to 60Hz Response: Averaging
Resistance Measurement
Range Resolution Accuracy
400Ω 0.1Ω 4kΩ 0.001kΩ 40kΩ 0.01kΩ 400kΩ 0.1kΩ 4MΩ 0.001MΩ 40MΩ 0.01MΩ ± (2.0% + 5 digits)
Overload Protection: 600V DC / AC
6
3
-6
± (0.8% + 2 digits)
± (1.0% + 10 digits)
± (1.2% + 2 digits)
0.5A
Page 4
ENGLISH
Capacitance Measurement
Range Resolution Accuracy
50nF 0.01nF ± (3.0% + 10 digits) 500nF 0.1nF 5μF 0.001μF 50μF 0.01μF
± (3.0% + 5 digits)
100μF 0.1μF
Overload Protection: 600V DC / AC
Frequency Measurement
Range Resolution Accuracy
50Hz 0.01Hz 500Hz 0.1Hz 5kHz 0.001kHz
± (0.1% + 3 digits) 50kHz 0.01kHz 100kHz 0.1kHz
Overload Protection: 600V DC / AC
Duty Cycle Measurement
Range Resolution Accuracy
0.1 ˜ 99.9% 0.1% ± (3.0% + 0 digits)
Overload Protection: 600V DC / AC
Temperature Measurement
Range Resolution Accuracy
-4 ˜ 1832°F 1°F ± (3.0% + 3 digits)
Overload Protection: 600V DC / AC
Diode Test
Overload Protection Resolution Open Circuit Voltage
600V DC / AC 1mV Appx. 1.5V
Continuity Test
Overload Protection Resolution Open Circuit Voltage
600V DC / AC 100mΩ Appx. 0.45V
WARRANTY
This product is warranted to be free from defects in materials and workmanship for a period of two years from the date of purchase. During this warranty period, Klein Tools has the option to repair or replace or refund the purchase price of any unit which fails to conform to this warranty under normal use and service. This warranty does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect, or improper maintenance. Batteries and damage resulting from failed batteries are not covered by warranty. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. Klein Tools shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. If your Klein product requires repair or for information on how to exercise your rights under the terms of this warranty, please contact Klein Tools at 1-877-775-5346.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
139560T
Loading...