Klein Tools CL380 Instruction Manual

INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 37
ESPAÑOL pg. 19
400A AC/DC Auto-Ranging Digital Clamp Meter
True RMS
Measurement Technology
Ω
• AC/DC CURRENT
• HIGH VISIBILITY DISPLAY
• NON-CONTACT VOLTAGE TESTING
• DC MICRO-AMPS
• AUTO-RANGING
• DATA & RANGE HOLD
• TEMPERATURE
CL380
2 m
-40° – 1832°F
-40° – 1000°C
2
GENERAL SPECIFICATIONS
Klein Tools CL380 is an automatically ranging true root mean square (TRMS) digital clamp meter that measures AC/DC current via the clamp, AC/DC voltage, DC microamps, resistance, continuity, frequency, capacitance, tests diodes via test-leads, and temperature via a thermocouple probe. It features a high visibility, reverse contrast LCD display that optimizes viewability both in dark or bright ambient lighting.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <95% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: 14° to 122°F (-10° to 50°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: 0.1 x (Quoted Accuracy) per °C above
28°C or below 18°C, corrections are required when ambient working temp is outside of Accuracy Temp range
• Dimensions: 8.66" x 3.03" x 1.61" (220 x 77 x 41 mm)
• Weight: 9.88 oz. (280 g) including batteries
• Calibration: Accurate for one year
• Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1, 61010-2-032,61010-2-033;
Certified to CSA STD.C22.2 NO. 61010-1, 61010-2-032,61010-2-033.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CATIII 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
400.0mV 0.1mV ±(1.8% + 5 digits)
4.000V 0.001V ±(1.5% + 5 digits)
40.00V 0.01V ±(1.2% + 5 digits)
400.0V 0.1V
600V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
400.0mV 0.1mV ±(1.0% + 8 digits)
4.000V 0.001V ±(0.8% + 3 digits)40.00V 0.01V
400.0V 0.1V
600V 1V ±(1.0% + 3 digits)
Input Impedance: ~10MΩ Frequency Range: 45 to 400Hz Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
40.00A 0.01A ±(2.0% + 9 digits)
400.0A 0.1A
DC Current
(A DC)
40.00A 0.01A ±(2.0% + 9 digits)
400.0A 0.1A
Frequency Range: 50 to 60Hz Minimum Current Measurable: 0.3A AC or DC
DC
Microamps
(DC µ)
200µA 0.1µA ±(1.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Resistance
400.0Ω 0.1Ω ±(1.2% + 5 digits)
4.000kΩ 0.001kΩ
±(1.2% + 3 digits)
40.00kΩ 0.01kΩ
400.0kΩ 0.1kΩ
4.000MΩ 0.001MΩ
40.00MΩ 0.01MΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Auto Power off: After ~5 minutes of inactivity.
Over Limit: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
40.00nF 0.01nF ±(4% + 25 digits)
400.0nF 0.1nF
±(4% + 8 digits)
4.000μF 0.001μF
40.00μF 0.01μF
400.0μF 0.1μF
4.000mF 0.001mF ±(10% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-40° to 103°F 1°F
±(2.0% + 8 digits)
104° to 931°F
±(1.6% + 5 digits)
932° to 1832°F
±(2.0% + 2 digits)
Temperature
°C
-40° to 40°C 1
°C
±(2.0% + 4 digits)
-41° to 500°C
±(1.5% + 3 digits)
501° to 1000°C
±(1.5% + 2 digits)
Maximum Input: 600V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9% 10Hz to 10kHz
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 600V AC RMS or 600V DC Voltage Range: 8V to 220V AC RMS
ENGLISH
WARNINGS
To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death.
• Before each use verify meter operation by measuring a known voltage or current.
5
WARNINGS
• Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT III or CAT IV rated test leads.
• Ensure test leads are fully seated into jacks, and keep fingers away from the metal probe contacts when making measurements.
• Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries when a low battery indicator appears.
• Do not attempt to measure resistance or continuity on a live circuit.
• Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
• To avoid risk of electric shock, disconnect leads from any voltage source before removing battery door.
• To avoid risk of electric shock, do not operate meter while battery door is removed
SYMBOLS ON METER
AC/DC Current Resistance (in Ohms)
NCV
Non-Contact Voltage tester Audible Continuity Double Insulated Class II
μA
DC Microamps Warning or Caution Risk of Electrical Shock Diode Capacitance
Hz
Frequency
%
Duty-cycle
V Voltage (Volts) A Amperage (Amps)
°F °
C
Temperature (Fahrenheit / Celsius)
SEL
Select
+
Positive
Negative
COM
Common Ground Backlight Brightness
OFF
Power Off
SYMBOLS ON LCD
AC AC (Alternating Current) DC DC (Direct Current)
Negative Reading Data Hold Auto Ranging MAX Maximum Value Hold
F
Farrads Diode
NCV
Non-Contact Voltage Tester Auto Power Off Low Battery Audible Continuity
°
F
Degrees (Fahrenheit)
°
C
Degrees (Celsius)
M
Mega (value x 106)
k
kilo (value x 103)
m
milli (value x 10-3)
μ
micro (value x 10-6)
n
nano (value x 10-9)
V
Volts
A
Amps Ohms
Hz%
Frequency/Duty Cycle
ZERO
DC Current Zero Function Hazardous Voltage Indicator Relative Mode
MIN Minimum Value Hold MAX Maximum Value Hold
MAX-MIN
Difference between MAX and MIN values
6
FEATURE DETAILS
1
6
2
13
3
10
12
5
8
7
4
ENGLISH
1.
4000 count LCD display
8.
"REL/ZERO" button
2.
Function selector switch9.HOLD/Brightness button
3.
Clamp
10.
Clamp trigger (press to open clamp)
4.
"COM" jack
11.
Arrow markings
5.
"VΩ" jack
12.
"SEL/NCV" button
6.
"RANGE" button
13.
Non-contact voltage testing antenna (NCV)
7.
"MAX/MIN" button
11
9
NOTE: There
are no user­serviceable parts inside meter.
7
FUNCTION BUTTONS
ON/OFF
To power ON the meter, rotate the Function Selector switch
2
from the OFF setting to any measurement setting. To power OFF the meter, rotate the Function Selector switch
2
to the OFF setting. The
Auto-Power Off icon
will be visible in the display. By default, the meter will automatically power OFF after 5 minutes of inactivity. If the meter automatically powers-OFF while in a measurement setting, rotate Function Selector
2
switch to any other setting (excluding the OFF setting) to power ON the meter. To deactivate Auto-Power OFF functionality press and hold the "SEL/NCV" button
12
before powering ON from the OFF setting. When Auto-Power OFF is deactivated, the Auto-Power Off icon
will not be visible in the display.
SEL / NCV BUTTON (FOR SECONDARY FUNCTIONS)
Pushing the SEL/NCV button 12 activates the secondary function for each application accessible by the function selector switch
2
. For voltage and current (excluding DC uA), it toggles between AC and DC. For the other functions, it switches between °F and °C, between Hz and % Duty-cycle, and between Continuity, Resistance, Capacitance and Diode-Test. The default function for each application is printed on the meter in white; the secondary function or functions for each setting is printed on the meter in orange.
SEL / NCV BUTTON (FOR NCV TESTING)
Press and hold the SEL/NCV button 12 to enter Non-contact Voltage Testing (NCV) mode to test for presence of AC voltage. The NCV icon and ‘EF’ will be present on the display. Approach the conductor under test leading with the sensing antenna
13
. In the presence of AC voltage the meter delivers visual warning signals as dashes on the display and audible signals (beeps). As the NCV sensing antenna
13
approaches the voltage source more dashes will be presented on the display and the frequency of the audible sound will increase. Release the "NCV" button to exit NCV testing mode.
NOTE: Only voltages of 70V AC or greater will be detected.
BACKLIGHT BRIGHTNESS
Press and hold the HOLD/Brightness button
9
to toggle between high and low brightness for the backlight. By default, the meter will use the low brightness setting.
RANGE
The meter defaults to auto-ranging mode for voltage and resistance measurements. This mode automatically determines the most appropriate measurement range for the testing that is being conducted. The
icon will be visible in the display. To manually force the meter
to measure in a different range, use the "RANGE" button
6
.
1. Press the "RANGE" button 6 to manually select measurement
range (
is deactivated on the LCD). Repeatedly press the
"RANGE" button
6
to cycle through the available ranges, stopping
once the desired range is reached.
2. To return to auto-ranging mode, press and hold the "RANGE"
button
6
for more than one second ( is reactivated).
8
MAX/MIN
The "MAX/MIN" function can be used when measuring with voltage, current, resistance, temperature, and DC μA functions. When the "MAX/MIN" button 7 is pressed, the meter keeps track of the Maximum and Minimum values, and the difference between the Maximum and Minimum values while continuing to take samples.
1. When measuring, press "MAX/MIN" button 7 to toggle between
the Maximum value (MAX), the Minimum value (MIN), and the difference between Maximum and Minimum (MAX-MIN) values. "
MAX
", "
MIN
", or "
MAX-MIN
" will appear on the display, indicating the value being shown. If a new maximum or minimum occurs the display updates with that new value.
2. Press "MAX/MIN" button 7 for more than one second to return to normal measuring mode.
RELATIVE MODE REL Measurement: Press REL/ZERO 8 to initiate measurement
relative to the current reading. The REL icon will be present on the display. Subsequent measurements are displayed relative to the original measurement. (Applies to AC/DC Voltage, AC Current, Capacitance, DC μA, and Temperature). Press REL/ZERO 8 again to exit relative mode.
DC ZERO Function: When measuring DC current with the clamp, press REL/ZERO to activate the DC current zero function. This will set the display to zero by subtracting the current value as an offset. The ZERO icon will be present on the display. Press REL/ZERO 8 again to exit DC current zero mode.
FUNCTION BUTTONS
ENGLISH
9
OPERATING INSTRUCTIONS
CONNECTING TEST LEADS
Do not test if leads are improperly seated. Results could cause intermittent display readings. To ensure proper connection, firmly press leads into the input jack completely.
TESTING IN CAT III / CAT IV MEASUREMENT LOCATIONS
Ensure the test lead shield is pressed firmly in place. Failure to use the CATIII / CATIV shield increases arc-flash risk.
TESTING IN CAT II MEASUREMENT LOCATIONS
CAT III / CAT IV shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall outlets. Take care not to lose the shields.
5/32"
(4 mm)
.7" (18 mm)
INCORRECT
CORRECT
10
ENGLISH
OPERATING INSTRUCTIONS
AC/DC CURRENT (LESS THAN 400A)
AC Current is measured by pressing the clamp trigger
10
to open the clamp and placing it around a current-carrying wire. When measuring, care should be taken to ensure that the clamp is completely closed with trigger
10
fully released, and that the
wire passes perpendicularly through the center of the clamp in line with the arrow markings
11
.
To measure current:
1. Rotate the Function Selector switch
2
to the 400A setting.
2. Place clamp around wire. The current measurement will be shown in the display.
NOTE: The meter defaults to AC measurement. Press the SEL/NCV button to toggle between AC and DC modes. The AC or DC icon on the display indicates which mode is selected.
NOTE: If the measurement is less than 40A, rotate the Function Selector switch
2
to the 40A setting for improved resolution.
NOTE: If non-zero values are displayed prior to measuring in DC current mode, a DC zero offset correction is required. With meter in DC current mode, press the REL/ZERO button
8
to activate the DC
current ZERO function.
ZERO
icon will be present on the display. Subsequent DC current measurements automatically subtract the offset correction for improved accuracy. Press REL/ZERO button
8
to return to normal measuring mode.
Disconnect test leads when measuring with the clamp.
WIRE
11
OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
V
setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the SEL/NCV button
12
to toggle between AC and DC modes. The AC or DC icon on the LCD indicates which mode is selected.
Apply test leads to the circuit to be tested to measure voltage. The meter will auto-range to display the measurement in the most appropriate range.
NOTE: If "–" appears on the LCD, this indicates negative polarity for DC voltage.
NOTE: When in a voltage setting and the test leads are open, readings of order mV may appear on the display. This is noise and is normal. By touching the test leads together to close the circuit the meter will measure zero volts.
NOTE: When voltages in excess of 25V AC or 60V DC are measured the hazardous voltage indicator
will be present on the display.
Red leadBlack lead
12
ENGLISH
Red leadBlack lead
CONTINUITY
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Ensure that the Continuity Testing icon
is visible on the display. If not,
press the "SEL/NCV" button
12
repeatedly until the icon is
shown.
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 10Ω, an audible signal will sound and display will show a resistance value indicating continuity. If circuit is open display will show "OL".
DO NOT attempt to measure continuity on a live circuit.
OPERATING INSTRUCTIONS
13
OPERATING INSTRUCTIONS
RESISTANCE MEASUREMENTS
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Press the "SEL/NCV" button
12
repeatedly until the resistance icon
appears on the display.
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit. The
meter will auto-range to display the measurement in the most appropriate range.
NOTE: When in a Resistance setting and the test leads are open (not connected across a resistor), or when a failed resistor is under test, the display will indicate "OL" This is normal.
DO NOT attempt to measure resistance on a live circuit.
Red leadBlack lead
14
ENGLISH
Red leadBlack lead
CAPACITANCE
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. To measure capacitance, press the "SEL/NCV" button
12
repeatedly
until nF appears on the display.
2. Remove power from circuit.
3. Measure capacitance by connecting test leads across the
capacitor. The meter will auto-range to display the measurement in the most appropriate range.
OPERATING INSTRUCTIONS
15
OPERATING INSTRUCTIONS
DIODE TEST
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Press the "SEL/NCV" button
12
repeatedly until the diode icon
appears on the display.
Touch test leads to diode. A reading of 200-800mV on display indicates forward bias, "OL" indicates reverse bias. An open device will show "OL" in both polarities. A shorted device will show approximately 0mV.
Red leadBlack lead
Red leadBlack lead
µA DC CURENT (LESS THAN 200 µA)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
DC μA setting. The "μA" and "DC" icons will appear on the display.
2. Remove power from circuit and open circuit at measurement point.
3. Connect test leads in series with the circuit.
4. Apply power to the circuit to take the measurement.
DO NOT attempt to measure more than 200µA.
16
ENGLISH
TEMPERATURE
1. Insert K-type thermocouple into the VΩ 5 and COM 4 jacks
(observe polarity markings on thermocouple and meter), and rotate function selector switch
2
to the Temperature setting.
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter Celsius scale, press the "SEL/NCV" button
12
once. Ensure that the
appropriate icon (either
°F
or °C) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When thermocouple tip and object are in thermal equilibrium, the measurement on the display will stabilize. The meter will auto­range to display the measurement in the most appropriate range.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase is suitable for temperatures below 446°F / 230°C only. To measure higher temperatures, a K-type thermocouple with the appropriate measurement range should be used.
K-Type Thermocouple
OPERATING INSTRUCTIONS
FREQUENCY / DUTY-CYCLE
1. Insert RED test lead into VΩ jack
5
and BLACK test lead into
COM jack
4
, and rotate function selector switch 2 to the
Frequency/Duty-Cycle
setting.
NOTE: The meter defaults to Frequency testing in this mode. To enter Duty-Cycle testing mode, press the "SEL/NCV" button
12
once. Ensure
that the appropriate icon (either
Hz
or %) appears on the display.
2. Measure by connecting test leads across the circuit.
Red leadBlack lead
17
MAINTENANCE
BATTERY REPLACEMENT
When indicator is displayed on LCD, batteries must be replaced.
1. Remove screw from battery door.
2. Replace 3 x AAA batteries (note proper polarity).
3. Replace battery door and fasten securely with screw.
T
o avoid risk of electric shock, disconnect leads from any voltage
source before removing battery door.
To avoid risk of electric shock, do not operate meter while
battery door is removed.