Klein-hummel KDA 212 User Manual

Page 1
KDA 212 Amplifier
2 CHANNEL DISTRIBUTED AUDIO POWER AMPLIFIERS
KEY FEATURES TECHNICAL SPECIFICATIONS
UL 2041 rating for plenum space installation Built-in K8 digital audio distribution system input Simple LED diagnostics Remote control and monitoring over K8 bus system Tile bridge accessory for ceiling installation Flange mounting ears allow flexible mounting locations Single channels drive down to 2-Ohms for parallel distributed systems Alternative to 70/100V systems Analog line level inputs summed to K8 digital inputs Daisy chain K8 digital input bus eliminates hubs and switches Channel pair bridges up to 3 times the individual channel power rating
PRODUCT DESCRIPTION
The plenum rated KDA series amplifiers enable the possibility of designing distributed amplified systems through the use of a single Cat 5 cable for digital audio distribution as well as remote control and monitoring with the K8 digital audio distribution system. Applications for KDA amplifiers include ceiling placement to drive multiple divisible conference rooms and meeting facilities, bridged and placed near reinforcement loudspeakers to create amplified systems out of passive loudspeakers and easy location in conference room furniture to drive media or overhead loudspeakers. Multiple KDA amplifiers may be daisy chained together eliminating the multiple long copper runs associated with 70/100V systems and allowing easy facility expansion with no concern for induced noise or ground loops. KDA amplifiers offer an efficient and effective alternative to creating large area multizone systems in new facilities by eliminating amplifier floor space requirements and ensuring quality operation.
Power Requirements
Power supply 100-230V (+/- 15%) Operating temperature 0°C, 45°C (32°F, 113°F) Weight 2 kg, 4.4 lbs External dimensions 8.62”(W) x 2.99”(H) x 6.1”(D)
Audio Section
Bandwith (1W, 8 Ohm) 20 Hz - 20kHz +/-0.2dB S/N ratio >110 db Distortion THD Max. < 1% from 1W to full power
(typically <0.05%)
Inputs Balanced to ground, 2 x Phoenix 3.81,
3-pin K8 digital audio bus, RJ45 in/thru
Gain -60 ... +10dB in 15 steps Outputs Phoenix 5.08, 4-pin
preliminary
Page 2
KDA 212 Amplifier
2 CHANNEL DISTRIBUTED AUDIO POWER AMPLIFIERS
OUTPUT POWER SPECIFICATIONS (Watts per channel, both channels driven, 1kHz, 1% THD+N
mains voltage Stereo Mode Bridged Mode
2 Ohm 4 Ohm 4 Ohm
230V 185 120 430 120V 170 110 380 100V 130 85 300
TECHNICAL SPECIFICATIONSK8 CONTROL FEATURES
Control Functions via K8
Monitoring Functions via K8:
Additional Amplifier Protection:
Power on/off, input gain, signal routing
Load impedance, temperature, input signal level, output voltage, output current
Load short shutdown and self recovery, thermal limiting, DC and infrasonic and ultrasonic frequency signal protection
MECHANICAL DRAWING
Link K8 loop through, RJ-45, passive
bus coupling
K8 / Analog Routing 2 x Rotary switch, behind front
panel, software override
K8 / Analog input gain 2 x Rotary switch, behind front
panel, software override Control Directly via K8 bus Termination Switch 4-position DIP Digital Audio Format 48 kHz sampling rate, 24 bit,
proprietary Latency ½ millisecond worst case, ana-
logue in to analogue out K8 Rear Panel Indicators Sync, Wink
K+H Vertriebs- und Entwicklungsgesellschaft mbH 170309